Safety of dobutamine-atropine stress echocardiography:: A prospective experience of 4033 consecutive studies

被引:77
|
作者
Mathias, W
Arruda, A
Santos, FC
Arruda, AL
Mattos, E
Osório, A
Campos, O
Gil, M
Andrade, JL
Carvalho, AC
机构
[1] UNIFESP, Paulista Sch Med, Echocardiog Labs, Sao Paulo, Brazil
[2] Exata Diagnost, Sao Paulo, Brazil
关键词
D O I
10.1016/S0894-7317(99)70182-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dobutamine-atropine stress echocardiography (DASE) is an established method and has been shown to be accurate for the detection of coronary artery disease. Still, there are few large clinical studies that analyze the safety of DASE in general of the safety of performing it on an ambulatory basis. Most studies use a target heart rate as the primary end point regardless of whether asymptomatic ischemia occurs. Such studies have shown a serious cardiac event rate of approximately 0.3%. We prospectively studied 4033 consecutive patients on an ambulatory basis and in the hospital with the use of DASE from July 1991 to December 1998. All tests were performed by an experienced physician, and all clinical and DASE data were stored in a large database organized at the beginning of the study. Dobutamine was infused in scalar doses of 5, 10, 20, 30, and 40 mu g/kg per minute in 3-minute stages. Development of a new wall motion abnormality, achievement of 85% of target heart, and end of the DASE infusion protocol were used as an end point. If 85% of the target heart rate was not achieved, atropine was infused up to 1 mg in the absence of myocardial ischemia, which was used in 1280 studies. There were 3645 diagnostic tests, and 388 (10%) were found to be nondiagnostic. This result was due to poor image quality in 115 (3%), end of protocol in negative-submaximal examinations in 124 (3%), and limiting side effects in 149 (4%). Thirty-seven percent of the tests showed positive results for myocardial ischemia. Major test-related cardiac complications occurred in 10 (0.25%) patients and included 1 ventricular fibrillation, 1 case of myocardial infarction, and 8 cases of sustained ventricular tachycardia. Atropine poisoning was observed in 5 (0.12%) patients. No deaths occurred as a direct or indirect consequence of DASE. We conclude that dobutamine-atropine stress echocardiography is a reasonably safe method for detection of coronary artery disease in the hospital or in an ambulatory basis. The use of new wall motion abnormality as 1 of the end points may prevent further ischemia-related complications.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [1] THE SAFETY AND TOLERABILITY OF DOBUTAMINE-ATROPINE STRESS ECHOCARDIOGRAPHY
    PINGITORE, A
    BIGI, R
    MATHIAS, W
    MATTIOLI, R
    QUARTACOLOSSO, M
    SEVESO, G
    PREVITALI, M
    CHIARANDA, G
    HEYMAN, J
    MORALES, MA
    GALATI, A
    GIGLI, G
    MORRA, P
    PETIX, N
    BEZANTE, GP
    DEALCANTARA, M
    LOWENSTEIN, J
    SCLAVO, MG
    GANDOLFO, N
    PINGITORE, A
    MAZZONI, V
    SICARI, R
    LANDI, P
    RACITI, M
    PICANO, E
    CIRCULATION, 1994, 90 (04) : 659 - 659
  • [2] SAFETY AND TOLERABILITY OF DOBUTAMINE-ATROPINE STRESS ECHOCARDIOGRAPHY - A PROSPECTIVE, MULTICENTER STUDY
    PICANO, E
    MATHIAS, W
    PINGITORE, A
    BIGI, R
    PREVITALI, M
    LANCET, 1994, 344 (8931): : 1190 - 1192
  • [3] SAFETY AND FEASIBILITY OF ACCELERATED DOBUTAMINE-ATROPINE STRESS ECHOCARDIOGRAPHY
    Tang, J.
    Gin, K.
    Lee, P. K.
    Nair, P.
    Tsang, T.
    Jue, J.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S251 - S251
  • [4] Safety of dobutamine-atropine stress echocardiography in patients with ventricular tachycardia
    Smart, S
    Roth, J
    Sagar, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 91776 - 91776
  • [5] REPRODUCIBILITY OF THE DOBUTAMINE-ATROPINE ECHOCARDIOGRAPHY STRESS TEST
    BELLOTTI, P
    FIORETTI, PM
    FORSTER, T
    MCNEILL, AJ
    ELSAID, ESM
    SALUSTRI, A
    ROELANDT, JRTC
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1993, 10 (01): : 93 - 97
  • [6] Impact of beta blockers on dobutamine-atropine stress echocardiography
    SanRoman, JA
    Vilacosta, I
    Rollan, MJ
    Castillo, JA
    SanchezHarguindey, L
    Aviles, FF
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (04): : 373 - 379
  • [7] Dobutamine-atropine stress echocardiography in essential hypertensive patients
    Miloradovic, V
    Jovanovic, M
    Miloradovic, M
    JOURNAL OF HYPERTENSION, 2002, 20 : S158 - S158
  • [8] DOBUTAMINE-ATROPINE STRESS ECHOCARDIOGRAPHY AND CENTRAL ANTICHOLINERGIC SYNDROME
    MYLES, P
    LANCET, 1994, 344 (8937): : 1636 - 1636
  • [9] Acute complications in dobutamine-atropine stress echocardiography.
    Breithardt, OA
    Flachskampf, FA
    Klues, HG
    ZEITSCHRIFT FUR KARDIOLOGIE, 1998, 87 (06): : 492 - 498
  • [10] A third generation dobutamine-atropine stress echocardiography protocol: Feasibility, accuracy, and safety.
    Schroder, K
    Beckmann, S
    Dingerkus, H
    Krahwinkel, W
    Nixdorff, U
    Voller, H
    Kursten, B
    CIRCULATION, 1996, 94 (08) : 3972 - 3972