Spectroscopic detection of Hydrogen peroxide with an optical fiber probe using chemically deposited Prussian blue

被引:22
作者
Khorami, Hamed Akbari [1 ,2 ]
Botero-Cadavid, Juan F. [1 ,2 ,3 ]
Wild, Peter [1 ,2 ]
Djilali, Ned [1 ,2 ]
机构
[1] Univ Victoria, Inst Integrated Energy Syst IESVic, Victoria, BC V8W 3P6, Canada
[2] Univ Victoria, Dept Mech Engn, Victoria, BC V8W 2Y2, Canada
[3] Univ Nacl Colombia Sede Medellin, Escuela Fis, Medellin, Colombia
基金
加拿大自然科学与工程研究理事会;
关键词
Chemical deposition; Hydrogen peroxide; Optical fiber sensor; Prussian blue; Single source precursor; Spectroscopic detection; THIN-FILMS; SENSOR; DEGRADATION; FABRICATION; REDUCTION; OXIDATION; NANOCUBES; MEMBRANE; CELLS;
D O I
10.1016/j.electacta.2013.10.186
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel fiber-optic hydrogen peroxide sensing probe was fabricated using chemically deposited ferric ferrocyanide, often referred to as Prussian blue (PB). The probe features a fast linear response and durability, due to the robustness and purity of the PB film. Potassium ferricyanide was used as a single source precursor in a straightforward chemical deposition of nanostructured PB onto the tip of a multimode optical fiber. Spectroscopic detection of hydrogen peroxide (H2O2) was performed based on the reduction of PB to Prussian white (PW) by agents like ascorbic acid, and oxidation of PW to PB by H2O2. Measurement of H2O2 concentration is based on the changes of the absorption spectrum, under visible light, of PB and PW. The fiber-optic probes exhibit a linear response to concentration on a log-log scale and are found suitable for determining small concentrations of H2O2. Multiple tests were performed to investigate the repeatability and durability of a sensor response and though requiring recalibration, the probes were found to remain functional for an extended period of time. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:416 / 424
页数:9
相关论文
共 48 条
[1]   Electrodeposited Prussian blue films: Annealing effect [J].
Agnihotry, S. A. ;
Singh, Punita ;
Joshi, Amish G. ;
Singh, D. P. ;
Sood, K. N. ;
Shivaprasad, S. M. .
ELECTROCHIMICA ACTA, 2006, 51 (20) :4291-4301
[2]   A hydrogen peroxide sensor for exhaled breath measurement [J].
Anh, DTV ;
Olthuis, W ;
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 :494-499
[3]   Sol-gel-derived prussian blue-silicate amperometric glucose biosensor [J].
Bharathi, S ;
Lev, O .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) :209-216
[4]   Detection of hydrogen peroxide using an optical fiber-based sensing probe [J].
Botero-Cadavid, Juan F. ;
Brolo, Alexandre G. ;
Wild, Peter ;
Djilali, Ned .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 :166-173
[5]   Hydrogen peroxide induces autophagic cell death in C6 glioma cells via BNIP3-mediated suppression of the mTOR pathway [J].
Byun, Yu Jeong ;
Kim, Seong Keun ;
Kim, Young Mi ;
Chae, Gue Tae ;
Jeong, Seong-Whan ;
Lee, Seong-Beom .
NEUROSCIENCE LETTERS, 2009, 461 (02) :131-135
[6]   Kinetics of methyl tert-butyl ether degradation and by-product formation during UV/hydrogen peroxide water treatment [J].
Chang, PBL ;
Young, TM .
WATER RESEARCH, 2000, 34 (08) :2233-2240
[7]   Strategies for fabrication of hydrogen peroxide sensors based on electrostatic self-assembly (ESA) method [J].
Del Villar, I ;
Matias, IR ;
Arregui, FJ ;
Echeverría, J ;
Claus, RO .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) :751-757
[8]   Fiber-optic hydrogen peroxide nanosensor [J].
Del Villar, I ;
Matías, IR ;
Arregui, FJ ;
Claus, RO .
IEEE SENSORS JOURNAL, 2005, 5 (03) :365-371
[9]   ESA-based in-fiber nanocavity for hydrogen-peroxide detection [J].
Del Villar, I ;
Matías, IR ;
Arregui, FJ ;
Claus, RO .
IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2005, 4 (02) :187-193
[10]  
Del Villar I, 2003, IEEE SENSOR, P393