A novel capacitive system for the concentration measurement of pneumatically conveyed pulverized fuel at power stations

被引:40
作者
Hu, HL [1 ]
Xu, TM
Hui, SE
Zhou, QL
机构
[1] Xian Jiaotong Univ, Dept Elect Engn, Shaanxi 710049, Peoples R China
[2] Xian Jiaotong Univ, Dept Thermal Engn, Shaanxi 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
pneumatically conveyed pulverized fuel; concentration measurement; capacitance sensor; source-grid sensing electrodes; correlated double sample (CDS); lock-in detector;
D O I
10.1016/j.flowmeasinst.2005.11.001
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A novel capacitive system for the concentration measurement of gas-solid flow in pneumatically conveyed pulverized fuel at power stations has been developed. The capacitance sensor for measuring the concentration uses source-grid sensing electrodes. An active sensor and a dummy sensor are used to form a differential configuration. In order to eliminate baseline drift, to be immune to stray capacitance, and to ensure accurate measurement under very low solids/air mass flux ratio conditions, a correlated double sample (CDS) technique and lock-in detector with closed loop are used in the interface circuit. A laboratory scale pneumatically conveyed pulverized fuel loop system incorporating facilities for calibration has been fabricated for this purpose. The test section is a vertical ceramic tube of diameter 100 mm with an upward flow direction and pulverized fuel has been used as the solid phase. Results demonstrate that the system is capable of achieving linearity within +/- 5% at different temperatures or moisture content. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 21 条
[1]  
Baxter L.K., 1997, CAPACITIVE SENSORS D
[2]   NONINTRUSIVE MEASUREMENT OF SOLIDS MASS-FLOW IN PNEUMATIC CONVEYING [J].
BECK, MS ;
GREEN, RG ;
THORN, R .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (07) :835-840
[3]   New design of the two-phase flowmeters [J].
Benes, P ;
Zehnula, K .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 86 (03) :220-225
[4]   HIGH-ACCURACY CIRCUITS FOR ON-CHIP CAPACITANCE RATIO TESTING OR SENSOR READOUT [J].
CAO, YM ;
TEMES, GC .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-ANALOG AND DIGITAL SIGNAL PROCESSING, 1994, 41 (09) :637-639
[5]   Circuit techniques for reducing the effects of op-amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization [J].
Enz, CC ;
Temes, GC .
PROCEEDINGS OF THE IEEE, 1996, 84 (11) :1584-1614
[6]   A low cost, high resolution interface circuit for differential capacitance transducer [J].
Hu, HL ;
Xu, TM ;
Hui, S .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2005, 33 (06) :727-735
[7]  
HU HL, IN PRESS SENSORS A
[8]  
JIN F, 1998, ON LINE FLOW MEASURE, P133
[9]  
LEWIS BM, 1998, ON LINE FLOW MEASURE, P90
[10]  
Malmgren M., 1998, ON LINE FLOW MEASURE, P126