Summertime concentrations and emissions of hydrogen sulfide at a mechanically ventilated swine finishing building

被引:0
作者
Ni, JQ [1 ]
Heber, AJ
Diehl, CA
Lim, TT
Duggirala, RK
Haymore, BL
机构
[1] Purdue Univ, Dept Agr & Biol Engn, W Lafayette, IN 47907 USA
[2] Nat Concepts Engn Inc, Lizton, IN USA
[3] ChemLink Int, St Louis, MO USA
[4] Enron Energy Serv, Houston, TX USA
来源
TRANSACTIONS OF THE ASAE | 2002年 / 45卷 / 01期
关键词
air quality; pig housing; environment in animal buildings; pollution sources; ventilation;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Hydrogen sulfide (H2S) concentration and emission at a modern mechanically ventilated swine finishing building with a deep pit were continuously measured for three summer months. Ventilation rates, temperatures, and pig inventory in the building were also continuously measured or recorded. A total of 88 d of valid data were obtained between 26 June and 25 September during which the average daily mean (ADM) ambient temperature was 21.8 degreesC. The test began with 887, 19-kg pigs in the building and ended with 874, 83-kg pigs. Hydrogen sulfide was measured with a sulfur dioxide (SO2) analyzer equipped with a thermal oxidizer that converted H2S to SO2. Building ventilation rates were determined by, continuously monitoring exhaust fan operation and differential static pressure. Daily mean building H2S concentrations ranged from 38 to 536 ppb. The ADM building concentration (average of three locations) was 173 +/- 21 ppb (mean +/- 95% confidence interval). The maximum concentration, averaged over 7- or 12-min sampling periods, was 1,624 ppb. The 25(th), 50(th) (median), and 75(th) percentile values were 413, 527, and 662 g/d for daily mean building H2S emission and 4.4, 5.8, and 12.4 g d(-1) AU(-1) (animal unit = 500 kg live mass present in the building)for daily mean specific emission, respectively. These H2S emissions were much greater than emissions measured or estimated in previous studies. Based on daily means, H2S concentration was inversely proportional (P < 0.05) to ventilation rate (r = -0.68), whereas building H2S emission was influenced somewhat (P < 0.05) by building temperature (r = 0.29) and ventilation rate (r = 0.23).
引用
收藏
页码:193 / 199
页数:7
相关论文
共 19 条
[1]  
American Industrial Hygiene Association (AIHA), 1989, OD THRESH CHEM EST O
[2]  
AVERY GL, 1975, T ASAE, V18, P149
[3]  
DOEBELIN EO, 1990, MEASUREMENT SYSTEMS
[4]  
DONHAM KJ, 1982, J OCCUP ENVIRON MED, V24, P142
[5]  
FORD SE, 2001, AGR VENTILATION FANS
[6]  
Hartung J., 1988, Volatile emissions from livestock farming and sewage operations. Proceedings of a workshop, Uppsala, Sweden 10-12 June 1987, P54
[7]  
Heber AJ, 1997, AMMONIA AND ODOUR EMISSIONS FROM ANIMAL PRODUCTION FACILITIES, PROCEEDINGS, VOLS 1 AND 2, P449
[8]  
Heber AJ, 2001, T ASAE, V44, P1765, DOI 10.13031/2013.7013
[9]  
Heber AJ, 2000, T ASAE, V43, P1895, DOI 10.13031/2013.3094
[10]  
JACOBS AV, 1957, ANAL CHEM, V29, P1349