Wastewater disinfection by ozone: main parameters for process design

被引:217
作者
Xu, P
Janex, ML
Savoye, P
Cockx, A
Lazarova, V
机构
[1] CIRSEE, Ondeo Serv, F-78230 Le Pecq, France
[2] Univ Montpellier 2, Lab Hydrosci, MSE, UMR 5569, F-34095 Montpellier 5, France
[3] Inst Natl Sci Appl, Lab GPI, F-31077 Toulouse 4, France
关键词
wastewater disinfection; ozone; process design; water quality; wastewater reuse; disinfection modelling;
D O I
10.1016/S0043-1354(01)00298-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wastewater disinfection by ozone was investigated at pilot scale on different wastewater effluents. Variations in operating conditions showed that a very low hydraulic retention time (2 min) was sufficient for efficient fecal coliform inactivation, provided a sufficient ozone dose was transferred to the effluent. Therefore. the transferred ozone dose appeared to be the critical parameter for the design of wastewater disinfection. As a consequence, the "Ct" approach commonly applied in drinking water treatment should not be used for wastewater ozonation. Design parameters of ozonation were proposed for two types of regulations, and for effluents of different qualities. It was demonstrated that only with an efficient filtration step one can meet stringent standards such as the California Title 22 criteria. In all cases, viruses were totally inactivated: consequently. viruses do not constitute a limiting factor in wastewater disinfection by ozone. The standard drinking water model failed to match the experimental data obtained on real wastewater effluents. A modified approach was successfully developed, based on the simultaneous consumption of ozone by the microorganisms and the organic matrix. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1043 / 1055
页数:13
相关论文
共 26 条
[1]   DETERMINATION OF OZONE IN WATER BY THE INDIGO METHOD - A SUBMITTED STANDARD METHOD [J].
BADER, H ;
HOIGNE, J .
OZONE-SCIENCE & ENGINEERING, 1982, 4 (04) :169-176
[2]  
COCKX A, 2000, P INT OZ ASS C WASS, P79
[3]   Evaluating bacterial aerobic spores as a surrogate for Giardia and Cryptosporidium inactivation by ozone [J].
Facile, N ;
Barbeau, B ;
Prévost, M ;
Koudjonou, B .
WATER RESEARCH, 2000, 34 (12) :3238-3246
[4]   INACTIVATION OF HEPATITIS-A VIRUS AND MS2 BY OZONE AND OZONE-HYDROGEN PEROXIDE IN BUFFERED WATER [J].
HALL, RM ;
SOBSEY, MD .
WATER SCIENCE AND TECHNOLOGY, 1993, 27 (3-4) :371-378
[5]  
Harakeh M.S., 1985, OZONE-SCI ENG, V6, P235
[6]   VIROLOGICAL STUDY OF DRINKING AND WASTEWATER DISINFECTION BY OZONATION [J].
HARTEMANN, P ;
BLOCK, JC ;
JORET, JC ;
FOLIGUET, JM ;
RICHARD, Y .
WATER SCIENCE AND TECHNOLOGY, 1983, 15 (05) :145-154
[7]   USE OF MS2 COLIPHAGE AS A SURROGATE FOR ENTERIC VIRUSES IN SURFACE WATERS DISINFECTED WITH OZONE [J].
HELMER, RD ;
FINCH, GR .
OZONE-SCIENCE & ENGINEERING, 1993, 15 (04) :279-293
[8]   Inactivation of Escherichia coli with ozone:: Chemical and inactivation kinetics [J].
Hunt, NK ;
Mariñas, BJ .
WATER RESEARCH, 1999, 33 (11) :2633-2641
[9]   Start-up and optimization of the ozone disinfection process at the Sebago Lake Water Treatment Facility [J].
Hunter, GF ;
Rakness, KL .
OZONE-SCIENCE & ENGINEERING, 1997, 19 (03) :255-272
[10]   Comparison of ozonation and AOPs combined with biodegradation for removal of THM precursors in treated sewage effluents [J].
Ito, K ;
Jian, W ;
Nishijima, W ;
Baes, AU ;
Shoto, E ;
Okada, M .
WATER SCIENCE AND TECHNOLOGY, 1998, 38 (07) :179-186