A new route for synthesis of N-methylimidazolium-grafted silica stationary phase and reevaluation in hydrophilic interaction liquid chromatography

被引:14
|
作者
Liu, Houmei [1 ,2 ,5 ]
Chen, Jia [1 ,2 ]
Li, Zhan [1 ,2 ]
Takafuji, Makoto [4 ]
Ihara, Hirotaka [4 ]
Qiu, Hongdeng [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Chem Northwestern Plant Resources, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China
[3] Chinese Acad Sci, Lanzhou Inst Chem Phys, State Key Lab Oxo Synth & Select Oxidat, Lanzhou 730000, Peoples R China
[4] Kumamoto Univ, Dept Appl Chem & Biochem, Fac Engn, 2-39-1 Kurokami, Kumamoto 8608555, Japan
[5] Univ Chinese Acad Sci, Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Solventless method; Controllable synthesis; Chromatographic stationary phase; N-Methylimidazolium-grafted silica; HILIC; IONIC LIQUID; SOLVENTLESS SYNTHESIS; PERFORMANCE; SEPARATION; EXTRACTION; PLATFORM; AMINES;
D O I
10.1016/j.talanta.2016.11.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a "solvent-free" and green method for controllable and quantitative preparation of chromatographic stationary phase has been proposed. About the method, the largely excess of functional monomer and strict control of the proportion between silane and silica are the two most important points. Due to the existence of excessive functional monomer, silane can be utilized at the maximum extent, thereby achieving quantitative and reproducible bonding. Meanwhile, the excessive monomer can also be well recycled. By this new method, we controllably synthesized three Sil-MIm columns with various bonding amounts to investigate how the bonding amounts influence separation performances. The experiment results stated in some cases the columns with appropriate bonding amounts rather than maximum, were the best to fulfil some specific tasks. Meanwhile, it also demonstrated how important it was to control the bonding amounts of stationary phase.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 50 条
  • [41] Poly(itaconic acid)-grafted silica stationary phase prepared in deep eutectic solvents and its unique performance in hydrophilic interaction chromatography
    Hu, Yongxing
    Cai, Tianpei
    Zhang, Haijuan
    Chen, Jia
    Li, Zuguang
    Qiu, Hongdeng
    TALANTA, 2019, 191 : 265 - 271
  • [42] Effect of silica gel modification with cyclofructans on properties of hydrophilic interaction liquid chromatography stationary phases
    Kozlik, Petr
    Simova, Veronika
    Kalikova, Kveta
    Bosakova, Zuzana
    Armstrong, Daniel W.
    Tesarova, Eva
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1257 : 58 - 65
  • [43] Preparation of pH-responsive stationary phase for reversed-phase liquid chromatography and hydrophilic interaction chromatography
    Ma, Qiao
    Chen, Ming
    Yin, Hong-Rui
    Shi, Zhi-Guo
    Feng, Yu-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) : 61 - 67
  • [44] Hydrophilic interaction liquid chromatography of aminoglycoside antibiotics with a diol-type stationary phase
    Ianni, Federica
    Pucciarini, Lucia
    Carotti, Andrea
    Saluti, Giorgio
    Moretti, Simone
    Ferrone, Vincenzo
    Sardella, Roccaldo
    Galarini, Roberta
    Natalini, Benedetto
    ANALYTICA CHIMICA ACTA, 2018, 1044 : 174 - 180
  • [45] A positively charged porous graphitic carbon stationary phase for hydrophilic interaction liquid chromatography
    Hou, Yanjie
    Zhang, Feifang
    Liu, Xuefang
    Ren, Yanjun
    Yang, Bingcheng
    TALANTA, 2017, 164 : 159 - 163
  • [46] Preparation and Characterization of the Neomycin-Bonded Silica Stationary Phase for Hydrophilic-Interaction Chromatography
    Peng, Xi-Tian
    Feng, Yu-Qi
    Hu, Xi-Zhou
    Hu, Ding-Jin
    CHROMATOGRAPHIA, 2013, 76 (9-10) : 459 - 465
  • [47] Preparation and Characterization of the Neomycin-Bonded Silica Stationary Phase for Hydrophilic-Interaction Chromatography
    Xi-Tian Peng
    Yu-Qi Feng
    Xi-Zhou Hu
    Ding-Jin Hu
    Chromatographia, 2013, 76 : 459 - 465
  • [48] Self-assembled cyclodextrin-modified gold nanoparticles on silica beads as stationary phase for chiral liquid chromatography and hydrophilic interaction chromatography
    Li, Yuanyuan
    Wei, Manman
    Chen, Tong
    Zhu, Nan
    Ma, Yulong
    TALANTA, 2016, 160 : 72 - 78
  • [49] A polyacrylamide-based silica stationary phase for the separation of carbohydrates using alcohols as the weak eluent in hydrophilic interaction liquid chromatography
    Cai, Jianfeng
    Cheng, Lingping
    Zhao, Jianchao
    Fu, Qing
    Jin, Yu
    Ke, Yanxiong
    Liang, Xinmiao
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1524 : 153 - 159
  • [50] Grafting copolymer brushes on polyhedral oligomeric silsesquioxanes silsesquioxane-decorated silica stationary phase for hydrophilic interaction liquid chromatography
    Bo, Chunmiao
    Li, Yan
    Liu, Bin
    Jia, Zhuanhong
    Dai, Xiaojun
    Gong, Bolin
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1659