Biocompatibility and biodegradability of Mg-Sr alloys: The formation of Sr-substituted hydroxyapatite

被引:247
作者
Bornapour, M. [1 ]
Muja, N. [2 ]
Shum-Tim, P. [3 ]
Cerruti, M. [4 ]
Pekguleryuz, M. [1 ]
机构
[1] McGill Univ, Montreal, PQ H3A 2B2, Canada
[2] McGill Univ, Lab Biomat Min & Mat Engn, Montreal, PQ H3A 2B2, Canada
[3] McGill Univ, Dept Cardiac Surg, Montreal, PQ H3H 1P3, Canada
[4] McGill Univ, Biointerface Lab, Montreal, PQ H3A 2B2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Biodegradation; Biocompatibility; Magnesium; Strontium; Cardiovascular stent; CA-DEFICIENT HYDROXYAPATITE; IN-VITRO DEGRADATION; MAGNESIUM ALLOYS; MECHANICAL-PROPERTIES; CORROSION-RESISTANCE; VIVO CORROSION; STRONTIUM; METAL; ELECTRODEPOSITION; IMPLANTS;
D O I
10.1016/j.actbio.2012.07.045
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnesium is an attractive material for use in biodegradable implants due to its low density, non-toxicity and mechanical properties similar to those of human tissue such as bone. Its biocompatibility makes it amenable for use in a wide range of applications from bone to cardiovascular implants. Here we investigated the corrosion rate in simulated body fluid (SBF) of a series of Mg-Sr alloys, with Sr in the range of 0.3-2.5%, and found that the Mg-0.5 Sr alloy showed the slowest corrosion rate. The degradation rate from this alloy indicated that the daily Sr intake from a typical stent would be 0.01-0.02 mg day(-1), which is well below the maximum daily Sr intake levels of 4 mg day(-1). Indirect cytotoxicity assays using human umbilical vascular endothelial cells indicated that Mg-0.5 Sr extraction medium did not cause any toxicity or detrimental effect on the viability of the cells. Finally, a tubular Mg-0.5 Sr stent sample, along with a WE43 control stent, was implanted into the right and left dog femoral artery. No thrombosis effect was observed in the Mg-0.5 Sr stent after 3 weeks of implantation while the WE43 stent thrombosed. X-ray diffraction demonstrated the formation of hydroxyapatite and Mg(OH)(2) as a result of the degradation of Mg-0.5 Sr alloy after 3 days in SBF. X-ray photoelectron spectroscopy further showed the possibility of the formation of a hydroxyapatite Sr-substituted layer that presents as a thin layer at the interface between the Mg-0.5 Sr alloy and the corrosion products. We believe that this interfacial layer stabilizes the surface of the Mg-0.5 Sr alloy, and slows down its degradation rate over time. (C) 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:5319 / 5330
页数:12
相关论文
共 73 条
[1]   Thermodynamic modelling of the Mg-Ca, Mg-Sr, Ca-Sr and Mg-Ca-Sr systems using the modified quasichemical model [J].
Aljarrah, M. ;
Medraj, M. .
CALPHAD-COMPUTER COUPLING OF PHASE DIAGRAMS AND THERMOCHEMISTRY, 2008, 32 (02) :240-251
[2]   Paired comparison of vascular wall reactions to Palmaz stents, Strecker tantalum stents, and Wallstents in canine iliac and femoral arteries [J].
Barth, KH ;
Virmani, R ;
Froelich, J ;
Takeda, T ;
Lossef, SV ;
Newsome, J ;
Jones, R ;
Lindisch, D .
CIRCULATION, 1996, 93 (12) :2161-2169
[3]   Strontium-substituted hydroxyapatite nanocrystals [J].
Bigi, Adriana ;
Boanini, Elisa ;
Capuccini, Chiara ;
Gazzano, Massimo .
INORGANICA CHIMICA ACTA, 2007, 360 (03) :1009-1016
[4]   FORMATION AND STRUCTURE OF CA-DEFICIENT HYDROXYAPATITE [J].
BLUMENTHAL, NC ;
BETTS, F ;
POSNER, AS .
CALCIFIED TISSUE INTERNATIONAL, 1981, 33 (02) :111-117
[5]   Investigation of the mechanical and degradation properties of Mg-Sr and Mg-Zn-Sr alloys for use as potential biodegradable implant materials [J].
Brar, Harpreet S. ;
Wong, Joey ;
Manuel, Michele V. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 7 :87-95
[6]   Incorporation and distribution of strontium in bone [J].
Dahl, SG ;
Allain, P ;
Marie, PJ ;
Mauras, Y ;
Boivin, G ;
Ammann, P ;
Tsouderos, Y ;
Delmas, PD ;
Christiansen, C .
BONE, 2001, 28 (04) :446-453
[7]   XPS study of some calcium compounds [J].
Demri, B ;
Muster, D .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 1995, 55 (3-4) :311-314
[8]  
Di Mario Carlo, 2004, J Interv Cardiol, V17, P391, DOI 10.1111/j.1540-8183.2004.04081.x
[9]   Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents:: a prospective, non-randomised multicentre trial [J].
Erbel, Raimund ;
Di Mario, Carlo ;
Bartunek, Jozef ;
Bonnier, Johann ;
de Bruyne, Bernard ;
Eberli, Franz R. ;
Erne, Paul ;
Haude, Michael ;
Heublein, Bernd ;
Horrigan, Mark ;
Ilsley, Charles ;
Boese, Dirk ;
Koolen, Jacques ;
Luescher, Thomas F. ;
Weissman, Neil ;
Waksman, Ron .
LANCET, 2007, 369 (9576) :1869-1875
[10]  