Application of ring study:: Water toxicity determinations by bioluminescence assay with Vibrio fischeri

被引:24
作者
Hemando, MD [1 ]
Malato, O
Farré, M
Fernandez-Alba, AR
Barceló, D
机构
[1] Univ Almeria, Dept Analyt Chem, Almeria 04120, Spain
[2] CSIC, II QAB, Dept Environm Chem, ES-08034 Barcelona, Spain
关键词
Vibrio fischeri; inter-laboratory; toxicity; environment; water analysis;
D O I
10.1016/j.talanta.2005.09.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Acceptance of toxicity bioassays as effective analytical tools in environmental areas needs guarantees of standardization but also validation. Ten European laboratories took part in an inter-laboratory study using different commercial devices based on bioluminescence inhibition of bacteria Vibrio fischeri. Reproducibility and stability by short toxicity endpoints, effective concentration that gives 10%, 50% and 80% of inhibition (EC10, EC50 and EC80) is evaluated. Parametric and non-parametric statistic is applied and performance of participant laboratories is addressed by z-scores calculated by non-parametric statistic. z-Score classification was based on harmonised protocol for proficiency testing of analytical laboratories (satisfactory \z\ <= 2; questionable 2 <\z\ <= 3; unsatisfactory \z\ > 3). Tested samples were phenol, 3,5-dichlorophenol and influent wastewater. Based on z-score classification, more than 70% of the laboratories showed a satisfactory performance for phenol, 3,5-dichlorophenol and influent wastewater (86%, 90% and 70%, respectively). Reproducibility and stability was observed in toxicant references and in wastewater samples. EC80 determination appears to be more robust that EC10 and EC50. EC determinations can be considered favorable at 5 and 15 min of exposition, in particular for EC80. The use of different commercial devices can not be considered an additional source of variation. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:370 / 376
页数:7
相关论文
共 28 条
[1]  
[Anonymous], 1991, T90320 AFNOR
[2]  
[Anonymous], 1997, 431 ISOIEC 1
[3]  
*ASTM, D56601995 ASTM
[4]   Toxicity evaluation of metal plating wastewater employing the Microtox® assay:: A comparison with cladocerans and fish [J].
Choi, K ;
Meier, PG .
ENVIRONMENTAL TOXICOLOGY, 2001, 16 (02) :136-141
[5]  
*DIN, 384121990 DIN
[6]  
Doherty FG, 1999, ENVIRON TOXICOL, V14, P375, DOI 10.1002/(SICI)1522-7278(1999)14:4<375::AID-TOX1>3.3.CO
[7]  
2-B
[8]   Interlaboratory study of the bioluminescence inhibition tests for rapid wastewater toxicity assessment [J].
Farré, M ;
Arranz, F ;
Ribó, J ;
Barceló, D .
TALANTA, 2004, 62 (03) :549-558
[9]   Pesticide toxicity assessment using an electrochemical biosensor with Pseudomonas putida and a bioluminescence inhibition assay with Vibrio fischeri [J].
Farré, M ;
Gonçalves, C ;
Lacorte, S ;
Barceló, D ;
Alpendurada, MF .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (08) :696-703
[10]   Toxicity evaluation of single and mixed antifouling biocides measured with acute toxicity bioassays [J].
Fernández-Alba, AR ;
Hernando, MD ;
Piedra, L ;
Chisti, Y .
ANALYTICA CHIMICA ACTA, 2002, 456 (02) :303-312