Surface Laplacian of scalp electrical signals and independent component analysis resolve EMG contamination of electroencephalogram

被引:31
作者
Fitzgibbon, S. P. [1 ,3 ,4 ]
DeLosAngeles, D. [2 ]
Lewis, T. W. [2 ,4 ]
Powers, D. M. W. [2 ,4 ,5 ]
Whitham, E. M. [1 ]
Willoughby, J. O. [1 ,3 ]
Pope, K. J. [2 ,4 ]
机构
[1] Flinders Univ S Australia, Sch Med, Adelaide, SA 5001, Australia
[2] Flinders Univ S Australia, Sch Comp Sci Engn & Math, Adelaide, SA 5001, Australia
[3] Flinders Univ S Australia, Ctr Neurosci, Adelaide, SA 5001, Australia
[4] Flinders Univ S Australia, Med Device Res Inst, Adelaide, SA 5001, Australia
[5] Beijing Univ Technol, Coll Comp Sci & Technol, Beijing 100124, Peoples R China
基金
芬兰科学院; 英国惠康基金; 英国医学研究理事会; 澳大利亚研究理事会;
关键词
EEG; Surface Laplacian; Independent component analysis; Electromyogram; Steady state response; Oddball task; Evoked response; EEG DATA; ARTIFACTS; MUSCLE; CORTEX;
D O I
10.1016/j.ijpsycho.2014.10.006
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
The serious impact of electromyogram (EMG) contamination of electroencephalogram (EEG) is well recognised. The objective of this research is to demonstrate that combining independent component analysis with the surface Laplacian can eliminate EMG contamination of the EEG, and to validate that this processing does not degrade expected neurogenic signals. The method involves sequential application of ICA, using a manual procedure to identify and discard EMG components, followed by the surface Laplacian. The extent of decontamination is quantified by comparing processed EEG with EMG-free data that was recorded during pharmacologically induced neuromuscular paralysis. The combination of the ICA procedure and the surface Laplacian, with a flexible spherical spline, results in a strong suppression of EMG contamination at all scalp sites and frequencies. Furthermore, the ICA and surface Laplacian procedure does not impair the detection of well-known, cerebral responses; alpha activity with eyes-closed; ERP components (N1, P2) in response to an auditory oddball task; and steady state responses to photic and auditory stimulation. Finally, more flexible spherical splines increase the suppression of EMG by the surface Laplacian. We postulate this is due to ICA enabling the removal of local muscle sources of EMG contamination and the Laplacian transform being insensitive to distant (postural) muscle EMG contamination. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 36 条
[1]   Increased gamma-range activity in human sensorimotor cortex during performance of visuomotor tasks [J].
Aoki, F ;
Fetz, EE ;
Shupe, L ;
Lettich, E ;
Ojemann, GA .
CLINICAL NEUROPHYSIOLOGY, 1999, 110 (03) :524-537
[2]  
Barlow J.S., 1986, Handbook of EEG and Clinical Neurophysiological Signals, V2, P15
[3]   Oscillatory gamma activity in humans: a possible role for object representation [J].
Bertrand, O ;
Tallon-Baudry, C .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2000, 38 (03) :211-223
[4]  
Buzaki G., 2006, Rhythms of the Brain
[5]   Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis [J].
Delorme, Arnaud ;
Sejnowski, Terrence ;
Makeig, Scott .
NEUROIMAGE, 2007, 34 (04) :1443-1449
[6]   Independent EEG Sources Are Dipolar [J].
Delorme, Arnaud ;
Palmer, Jason ;
Onton, Julie ;
Oostenveld, Robert ;
Makeig, Scott .
PLOS ONE, 2012, 7 (02)
[7]  
DeLosAngeles D., 2010, ELECTROENCEPHALOGRAP, DOI DOI 10.1016/S1388-2457(03)00045-2
[8]   TEMPORAL CODING IN THE VISUAL-CORTEX - NEW VISTAS ON INTEGRATION IN THE NERVOUS-SYSTEM [J].
ENGEL, AK ;
KONIG, P ;
KREITER, AK ;
SCHILLEN, TB ;
SINGER, W .
TRENDS IN NEUROSCIENCES, 1992, 15 (06) :218-226
[9]   Removal of EEG noise and artifact using blind source separation [J].
Fitzgibbon, S. P. ;
Powers, D. M. W. ;
Pope, K. J. ;
Clark, C. R. .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2007, 24 (03) :232-243
[10]  
Fitzgibbon S.P., AUTOMATIC DETE UNPUB