Blood Warming and Hemolysis: A Systematic Review With Meta-Analysis

被引:29
作者
Poder, Thomas G. [1 ,2 ]
Nonkani, Wendyam G. [3 ]
Leponkouo, Elyonore Tsakeu [3 ]
机构
[1] UETMIS, Sherbrooke, PQ, Canada
[2] CRCHUS, Sherbrooke, PQ, Canada
[3] Univ Auvergne, CERDI, Clermont Ferrand, France
关键词
Fluid warmer; Blood warmer; Hemolysis; Free hemoglobin; Red blood cells; Temperature; ERYTHROCYTE DAMAGE; INFUSION PUMPS; STORED-BLOOD; WARMED BLOOD; TRANSFUSION; CELLS; HEAT; TEMPERATURE; PRESSURE; STORAGE;
D O I
10.1016/j.tmrv.2015.03.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of fluid warmers during blood transfusion is recommended to avoid inducing hypothermia and its harmful effects. Fluid warmers offered by manufacturers can reach temperatures of 43 degrees C. However, the recommendations of national regulatory organizations do not clearly indicate the maximum heating temperature in relation to the risk of hemolysis. To fill this gap, we conducted a systematic review of the literature with meta-analysis. To match clinical practice, this review was limited to fluid warmers that used contact heating; thus, studies that used radiofrequency or microwave heating were excluded. Twenty-four observational studies were included, 17 of which were the subject of a meta-analysis. A preliminary descriptive analysis indicated that multiple factors can influence the level of hemolysis during blood heating with a liquid warmer, including blood age, anticoagulant type, duration of exposure to heat, stirring the blood during heating, and various elements of the circuit through which blood flows (eg, type of infusion pump with pressure and flow, type of microfilter, and type of tubing). Moreover, the duration between sampling and hemolysis assay was a source of heterogeneity among studies, as were the initial free hemoglobin levels in the various experiments. In general, the increase generated by each of these factors other than temperature appears to have been limited except for blood age, which is an important parameter of hemolysis, the length of exposure to heat, and, in some studies, the type of infusion pump used. Regarding the meta-analysis, at temperatures at or less than 43 degrees C and even up to 45-46 degrees C, it appears that blood heating is safe and causes hemolysis only in clinically negligible proportions. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:172 / 180
页数:9
相关论文
共 45 条
  • [1] AABB, 2012, STANDARDS BLOOD BANK, V28th, P1
  • [2] HEMOLYTIC AND PSEUDO-HEMOLYTIC TRANSFUSION REACTIONS - AN OVERVIEW OF THE HEMOLYTIC TRANSFUSION REACTIONS AND THE CLINICAL CONDITIONS THAT MIMIC THEM
    BEAUREGARD, P
    BLAJCHMAN, MA
    [J]. TRANSFUSION MEDICINE REVIEWS, 1994, 8 (03) : 184 - 199
  • [3] USE OF WARMED BLOOD FOR TRANSFUSION
    BENNETT, PJ
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1968, 61 (07): : 687 - &
  • [4] WHEN DOES BLOOD HEMOLYZE
    CHALMERS, C
    RUSSELL, WJ
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1974, 46 (10) : 742 - 746
  • [5] Ciavarella D, 1988, Transfus Med Rev, V2, P95, DOI 10.1016/S0887-7963(88)70036-X
  • [6] PLATELET ROTATORS, INFUSION PUMPS AND BLOOD WARMERS
    CUMMINGS, E
    [J]. TRANSFUSION SCIENCE, 1989, 10 (03): : 199 - 206
  • [7] Red blood cell storage: the story so far
    D'Alessandro, Angelo
    Liumbruno, Giancarlo
    Grazzini, Giuliano
    Zolla, Lello
    [J]. BLOOD TRANSFUSION, 2010, 8 (02) : 82 - 88
  • [8] Dalili H, 1973, ANESTH ANALG, V53, P125
  • [9] EFFECTS OF A DRY HEAT BLOOD WARMER ON SOME COMPONENTS OF STORED BLOOD
    DESMONTS, JM
    DULVALDESTIN, P
    HENZEL, D
    [J]. ANAESTHESIA, 1975, 30 (02) : 230 - 232
  • [10] Du Plessis J M, 1966, S Afr Med J, V40, P479