Leak detection through microwave reflectometry: From laboratory to practical implementation

被引:31
作者
Cataldo, Andrea [1 ]
De Benedetto, Egidio [1 ]
Cannazza, Giuseppe [1 ]
Giaquinto, Nicola [2 ]
Savino, Mario [2 ]
Adamo, Francesco [2 ]
机构
[1] Univ Salento, Dept Engn Innovat, I-73100 Lecce, Italy
[2] Polytech Bari, Dept Elect & Informat Engn, I-70125 Bari, Italy
关键词
Leak detection; Microwave reflectometry; Pipe networks; Time domain reflectometry; Underground pipes; Water leakage; TIME-DOMAIN REFLECTOMETRY; SOIL-WATER CONTENT; ELECTRICAL-CONDUCTIVITY; BURIED PIPES; SANDY SOILS; TDR;
D O I
10.1016/j.measurement.2013.09.010
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work aims at assessing the practical applicability of an innovative time domain reflectometry (TDR)-based system for leak localization in underground pipes. For this purpose, two laboratory experiments were carried out. The first experiment (E1) allowed assessing the reliability of the TDR system in presence of two simultaneous leakage-like conditions. The second experiment (E2), which was also carried out in presence of two leaks, allowed assessing the possible effect of the type of soil on the performance of the leak-detection system. Results show that, differently from traditional leak detection methods, the TDR-based system can correctly localize the presence of two simultaneous, closely-spaced leaks and that the type of soil has very little influence on the performance of the system. Finally, in this work, the practical implementation of the system in urban areas is also addressed, thus highlighting the steps to maximize the effectiveness of the system. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:963 / 970
页数:8
相关论文
共 43 条
[1]   Leak detection in water-filled plastic pipes through the application of tuned wavelet transforms to Acoustic Emission signals [J].
Ahadi, Majid ;
Bakhtiar, Mehrdad Sharif .
APPLIED ACOUSTICS, 2010, 71 (07) :634-639
[2]  
Andrews J.R., 2004, AN15 PIC PULS LABS
[3]  
[Anonymous], 2004, MICROWAVE ELECT MEAS
[4]   Enhancing TDR based water content measurements by ANN in sandy soils [J].
Arsoy, Sami ;
Ozgur, Mehmet ;
Keskin, Erdinc ;
Yilmaz, Cuneyt .
GEODERMA, 2013, 195 :133-144
[5]   Leak rate metrology for the society and industry [J].
Bergoglio, M. ;
Mari, D. .
MEASUREMENT, 2012, 45 (10) :2434-2440
[6]   Detection of water leaks in supply pipes using continuous wave sensor operating at 2.45 GHz [J].
Bimpas, Matthaios ;
Amditis, Angelos ;
Uzunoglu, Nikolaos .
JOURNAL OF APPLIED GEOPHYSICS, 2010, 70 (03) :226-236
[7]   A Rapid-Acquisition Electrical Time-Domain Reflectometer for Dynamic Structure Analysis [J].
Bishop, Joseph A. ;
Pommerenke, David J. ;
Chen, Genda .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (02) :655-661
[8]   An electromagnetic-based method for pinpointing leaks in buried pipes: a practical validation [J].
Cataldo, A. ;
Cannazza, G. ;
De Benedetto, E. ;
Miraglia, M. ;
Ancora, D. ;
Giaquinto, N. .
WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2013, 13 (04) :966-976
[9]   A TDR-based system for the localization of leaks in newly installed, underground pipes made of any material [J].
Cataldo, A. ;
Cannazza, G. ;
De Benedetto, E. ;
Giaquinto, N. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (10)
[10]   Assessment of a TD-Based Method for Characterization of Antennas [J].
Cataldo, A. ;
Monti, G. ;
De Benedetto, E. ;
Cannazza, G. ;
Tarricone, L. ;
Catarinucci, L. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (05) :1412-1419