Chronological Changes in the Ultrastructure of Titanium-Bone Interfaces: Analysis by Light Microscopy, Transmission Electron Microscopy, and Micro-Computed Tomography

被引:26
|
作者
Morinaga, Kenzo [1 ]
Kido, Hirofumi [1 ]
Sato, Atsuko [2 ]
Watazu, Akira [3 ]
Matsuura, Masaro [1 ]
机构
[1] Fukuoka Dent Coll, Sect Oral Implantol, Dept Oral Rehabil, Sawara Ku, Fukuoka 8140193, Japan
[2] Fukuoka Dent Coll, Dept Morphol Biol, Sect Funct Struct, Sawara Ku, Fukuoka 8140193, Japan
[3] Natl Inst Adv Ind Sci & Technol, Moriyama Ku, Nagoya, Aichi 4638560, Japan
关键词
chronological observation; micro-CT; osseointegration; quantitative computer tomography; titanium coating; ultrastructure; TISSUE-RESPONSE; RAT MAXILLA; IMPLANTS; MICROARCHITECTURE; TIBIAE; CELLS; YOUNG;
D O I
10.1111/j.1708-8208.2008.00093.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objectives of this study were to chronologically examine the titanium-bone interfaces and to clarify the process of osseointegration using light microscopy, transmission electron microscopy (TEM), and micro-computed tomography (CT). Experimental implants (Ti-coating plastic implants) were placed into tibiae of 8-week-old rats. Animals were sacrificed at 1 to 28 days after implant placement and prepared tissue specimens for a light microscope, a TEM, and micro-CT. New bone formation began 5 days after implant placement, and osseointegration was obtained by 14 days after implant placement. Osseointegration was well developed by 28 days after implant placement. TEM and quantitative computer tomography (QCT) results indicated that bone formation in osseointegration of titanium implants did not occur from the surfaces of the implant or preexisting bone, but it was likely that bone formation progressed at a site a small distance away from the surface. The bone formation took place in a scattered manner. Small bone fragments adhered to each other and transformed into reticular-shaped bone, and finally these bones became lamellar bone. Comparative analysis of the titanium-bone interfaces using light microscopy, TEM, and QCT by micro-CT revealed the precise process of osseointegration.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 34 条
  • [1] Histomorphometry and micro-computed tomography of bone augmentation under a titanium membrane
    Maréchal, M
    Luyten, F
    Nijs, J
    Postnov, A
    Schepers, E
    van Steenberghe, D
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (06) : 708 - 714
  • [2] Remineralization effect of three different agents on initial caries and erosive lesions: a micro-computed tomography and scanning electron microscopy analysis
    Sibel Akküç
    Gülsüm Duruk
    Ali Keleş
    BMC Oral Health, 23
  • [3] Remineralization effect of three different agents on initial caries and erosive lesions: a micro-computed tomography and scanning electron microscopy analysis
    Akkuc, Sibel
    Duruk, Gulsum
    Keles, Ali
    BMC ORAL HEALTH, 2023, 23 (01)
  • [4] Cleat structure analysis and permeability simulation of coal samples based on micro-computed tomography (micro-CT) and scan electron microscopy (SEM) technology
    Roslin, Alexandra
    Pokrajac, Dubravka
    Zhou, Yingfang
    FUEL, 2019, 254
  • [5] The Effect of Micro-Computed Tomography Thresholding Methods on Bone Micromorphometric Analysis
    Buyuksungur, Arda
    Szabo, Bence Tamas
    Dobai, Adrienn
    Orhan, Kaan
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (11)
  • [6] Comparison of three retreatment techniques with ultrasonic activation in flattened canals using micro-computed tomography and scanning electron microscopy
    Bernardes, R. A.
    Duarte, M. A. H.
    Vivan, R. R.
    Alcalde, M. P.
    Vasconcelos, B. C.
    Bramante, C. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (09) : 890 - 897
  • [7] Micro-computed tomography analysis of early stage bone healing using micro-porous titanium mesh for guided bone regeneration: preliminary experiment in a canine model
    Rakhmatia, Yunia Dwi
    Ayukawa, Yasunori
    Jinno, Yohei
    Furuhashi, Akihiro
    Koyano, Kiyoshi
    ODONTOLOGY, 2017, 105 (04) : 408 - 417
  • [8] Variation in sex expression and flower development in Piper nigrum (black pepper) assessed with micro-computed tomography and scanning electron microscopy
    Nilni A. Wimalarathna
    Maria Von Balthazar
    Anushka M. Wickramasuriya
    Mark W. Chase
    Rosabelle Samuel
    Kahandawa G. S. U. Ariyawansa
    Dharshani Bandupriya
    Tara D. Silva
    Brazilian Journal of Botany, 48 (1)
  • [9] Microarchitectural properties of compacted cancellous bone allografts: A morphology micro-computed tomography analysis
    Putzer, D.
    Pallua, J.
    Degenhardt, G.
    Dammerer, D.
    Nogler, M.
    Arora, R.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 160
  • [10] Architectural Changes in Subchondral Bone and Its Compliance in Response to Estrogen and Progesterone: A Micro-Computed Tomography Study
    Yang, Jae-Hyuk
    Woo, Dae-Gon
    Tyagi, Vineet
    Oh, Kwang-Jun
    TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2011, 8 (04) : 380 - 389