International comparison of quantum AC voltage standards for frequencies up to 100 kHz

被引:20
作者
Filipski, Piotr S. [2 ]
van den Brom, Helko E. [1 ]
Houtzager, Ernest [1 ]
机构
[1] VSL Dutch Metrol Inst, Delft, Netherlands
[2] Natl Res Council Canada, Ottawa, ON, Canada
关键词
Josephson arrays; Signal synthesis; Standards; AC voltage standard; ERROR;
D O I
10.1016/j.measurement.2012.03.008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents results of an international comparison of two quantum AC voltage standards based on pulse-driven Josephson arrays. The two systems differ in several hardware and software characteristics as well as in the level of automation, features which can influence the accuracy of transferring the quantum-standard voltage value to a calibrated instrument. The comparison was performed at 100 mV, 20 mV and 12 mV, at frequencies between 2.5 kHz and 100 kHz. An electronically-aided thermal transfer standard was used as a travelling standard. At the most accurate voltage and frequency point, 100 mV at 2.5 kHz, both laboratories agreed to better than 1 part in 10(6). (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2218 / 2225
页数:8
相关论文
共 15 条
  • [1] Precision measurements using a 300 mV Josephson arbitrary waveform synthesizer
    Benz, S. P.
    Dresselhaus, P. D.
    Burroughs, C. J.
    Bergren, N. F.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 864 - 869
  • [2] Progress Toward a 1 V Pulse-Driven AC Josephson Voltage Standard
    Benz, Samuel P.
    Dresselhaus, Paul D.
    Ruefenacht, Alain
    Bergren, Norman F.
    Kinard, Joseph R.
    Landim, Regis Pinheiro
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) : 838 - 843
  • [3] Operating conditions for a pulse-quantized AC and DC bipolar voltage source
    Benz, SP
    Burroughs, CJ
    Harvey, TE
    Hamilton, CA
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 3306 - 3309
  • [4] A pulse-driven programmable Josephson voltage standard
    Benz, SP
    Hamilton, CA
    [J]. APPLIED PHYSICS LETTERS, 1996, 68 (22) : 3171 - 3173
  • [5] Filipski P. S., 2010, 2010 NCSL INT WORKSH, P9
  • [6] Experimental Determination of the Voltage Lead Error in an AC Josephson Voltage Standard
    Filipski, Piotr S.
    Boecker, Michael
    Benz, Samuel P.
    Burroughs, Charles J., Jr.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (07) : 2387 - 2392
  • [7] Correction of Systematic Errors Due to the Voltage Leads in an AC Josephson Voltage Standard
    Filipski, Piotr S.
    Kinard, Joseph R.
    Lipe, Thomas E.
    Tang, Yi-Hua
    Benz, Samuel P.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) : 853 - 858
  • [8] Houtzager E, 2010, 2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, P185, DOI 10.1109/CPEM.2010.5543462
  • [9] Operating Margins for a Pulse-Driven Josephson Arbitrary Waveform Synthesizer Using a Ternary Bit-Stream Generator
    Houtzager, Ernest
    Benz, Samuel P.
    van den Brom, Helko E.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) : 775 - 780
  • [10] High precision comparison between a programmable and a pulse-driven Josephson voltage standard
    Jeanneret, Blaise
    Ruefenacht, Alain
    Overney, Frederic
    van den Brom, Helko
    Houtzager, Ernest