Feasibility analysis of a Darrieus vertical-axis wind turbine installation in the rooftop of a building

被引:241
作者
Balduzzi, Francesco [1 ]
Bianchini, Alessandro [1 ]
Carnevale, Ennio Antonio [1 ]
Ferrari, Lorenzo [1 ]
Magnani, Sandro [1 ]
机构
[1] Univ Florence, Sergio Stecco Dept Energy Engn, I-50139 Florence, Italy
关键词
Darrieus; VAWT; Urban context; Skewed flow; Microeolic turbine; CFD SIMULATION; MODELS;
D O I
10.1016/j.apenergy.2011.12.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The renewed interest that is being paid by architects, project developers and local governments to small-size wind turbines is mainly connected to the attractive prospects of future applications in the urban environment; the delocalized power production of these systems could indeed provide an effective answer to both the growing demand for renewable energy and the increased attention in buildings with a sustainable and low-energy design. In particular, Darrieus vertical-axis wind turbines (VAWTs) are being considered as one of the most attractive solutions due to their low visual impact, the reduced acoustic emissions and their better response to a turbulent and skewed oncoming flow. The feasibility of this scenario has, however, to be proved yet; in particular, doubts are still connected to the real producibility in a complex terrain like the urban one and to the compatibility of microeolic machines with a densely populated area. On these assumptions, the aim of this work is to critically evaluate the energetic suitability of a Darrieus VAWT installation in the rooftop of a building in a reference European city. With this goal in mind, a numerical CFD analysis was carried out to characterize the flow field in the rooftop area of buildings with different shapes and geometrical proportions: the flow velocity modulus and direction were calculated for different oncoming wind profiles and the results were projected into a net available wind distribution in the rooftop of each building. As a second step, in order to provide a reliable estimation of the real functioning of the turbine in the investigated environment, a specific numerical model has been developed to account for the effects of a skewed flow on the power performance of the Darrieus rotor. The results of these analyses were finally combined and synthesized in an energy-oriented study to evaluate the feasibility of a rooftop installation. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:921 / 929
页数:9
相关论文
共 31 条
[21]   Performance of an H-Darrieus in the skewed flow on a roof [J].
Mertens, S ;
van Kuik, G ;
van Bussel, G .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (04) :433-440
[22]  
Mertens S., 2006, Wind Energy in the Built Environment: Concentrator Effects of Buildings
[23]  
Paraschivoiu I., 1981, Second DOE/NASA wind turbines dynamics workshop, P19
[24]  
Paraschivoiu I., 2002, Wind turbine design: with emphasis on darrieus concept
[25]  
Ratti C, 2002, URBAN AIR QUALITY - RECENT ADVANCES, PROCEEDINGS, P459
[26]   APPROPRIATE BOUNDARY-CONDITIONS FOR COMPUTATIONAL WIND ENGINEERING MODELS USING THE KAPPA-EPSILON TURBULENCE MODEL [J].
RICHARDS, PJ ;
HOXEY, RP .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1993, 46-7 :145-153
[27]  
Simao Ferreira C. J, 2006, P EUR WIND EN C 2006
[28]  
Syngellakis K., 2006, P EUR WIND EN C 2006
[29]   AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings [J].
Tominaga, Yoshihide ;
Mochida, Akashi ;
Yoshie, Ryuichiro ;
Kataoka, Hiroto ;
Nozu, Tsuyoshi ;
Yoshikawa, Masaru ;
Shirasawa, Taichi .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2008, 96 (10-11) :1749-1761
[30]  
US Energy Information Administration (EIA), 2006, 2005 RES EN CONS SUR