Width-Modulated Square-Wave Pulses for Ultrasound Applications

被引:47
作者
Smith, Peter R. [1 ]
Cowell, David M. J. [1 ]
Freear, Steven [1 ]
机构
[1] Univ Leeds, Sch Elect & Elect Engn, Ultrasound Grp, Leeds, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
MEDICAL ULTRASOUND; EXCITATION SIGNALS; LOW-COST; GENERATOR; DESIGN; IMPLEMENTATION; PERFORMANCE; WINDOWS; SYSTEM;
D O I
10.1109/TUFFC.2013.6644730
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A method of output pressure control for ultrasound transducers using switched excitation is described. The method generates width-modulated square-wave pulse sequences that are suitable for driving ultrasound transducers using MOSFETs or similar devices. Sequences are encoded using an optimized level-shifted, carrier-comparison, pulse-width modulation (PWM) strategy derived from existing PWM theory, and modified specifically for ultrasound applications. The modifications are: a reduction in carrier frequency so that the smallest number of pulses are generated and minimal switching is necessary; alteration of a linear carrier form to follow a trigonometric relationship in accordance with the expected fundamental output; and application of frequency modulation to the carrier when generating frequency-modulated, amplitude-tapered signals. The PWM method permits control of output pressure for arbitrary waveform sequences at diagnostic frequencies (approximately 5 MHz) when sampled at 100 MHz, and is applicable to pulse shaping and array apodization. Arbitrary waveform generation capability is demonstrated in simulation using convolution with a transducer's impulse response, and experimentally with hydrophone measurement. Benefits in coded imaging are demonstrated when compared with fixed-width square-wave (pseudo-chirp) excitation in coded imaging, including reduction in image artifacts and peak side-lobe levels for two cases, showing 10 and 8 dB reduction in peak side-lobe level experimentally, compared with 11 and 7 dB reduction in simulation. In all cases, the experimental observations correlate strongly with simulated data.
引用
收藏
页码:2244 / 2256
页数:13
相关论文
共 33 条
[11]   A Look-Up-Table Digital Predistortion Technique for High-Voltage Power Amplifiers in Ultrasonic Applications [J].
Gao, Zheng ;
Gui, Ping .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) :1550-1557
[12]  
HARRIS FJ, 1978, P IEEE, V66, P51, DOI 10.1109/PROC.1978.10837
[13]  
Holmes D. G., 2003, Pulse Width Modulation for Power Convert- ers: Principles and Practice, V18
[14]   Design and Implementation of a Smartphone-Based Portable Ultrasound Pulsed-Wave Doppler Device for Blood Flow Measurement [J].
Huang, Chih-Chung ;
Lee, Po-Yang ;
Chen, Pay-Yu ;
Liu, Ting-Yu .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (01) :182-188
[15]   Arbitrary waveform coded excitation using bipolar square wave pulsers in medical ultrasound [J].
Huang, SW ;
Li, PC .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) :106-116
[16]  
Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351
[17]  
Jensen JA, 2004, 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, P636
[18]   A Single FPGA-Based Portable Ultrasound Imaging System for Point-of-Care Applications [J].
Kim, Gi-Duck ;
Yoon, Changhan ;
Kye, Sang-Bum ;
Lee, Youngbae ;
Kang, Jeeun ;
Yoo, Yangmo ;
Song, Tai-Kyong .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) :1386-1394
[19]   Multicarrier PWM strategies for multilevel inverters [J].
McGrath, BP ;
Holmes, DG .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2002, 49 (04) :858-867
[20]   Use of modulated excitation signals in medical ultrasound. Part III: High frame rate imaging [J].
Misaridis, T ;
Jensen, JA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) :208-219