Thermal Management Systems for Data Centers with Liquid Cooling Technique of CPU

被引:0
|
作者
Ouchi, Mayumi [1 ]
Abe, Yoshiyuki [1 ]
Fukagaya, Masato
Ohta, Haruhiko
Shinmoto, Yasuhisa
Sato, Masahide
Iimura, Ken-ichi
机构
[1] AIST, Energy Enabling Tech Grp, Cent 2,Umezono 1-1-1, Tsukuba, Ibaraki 3058568, Japan
来源
2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM) | 2012年
关键词
single-phase heat exchanger; two-phase heat exchanger; flat heat pipes; nanofluids; energy conservation; plug-in system; PUE;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy consumption in data centers has seen a drastic increase in recent years and approximately 40% of it is spent on cooling facilities. In data centers, server racks are cooled down indirectly by chilled air with an air conditioner. This technique is inefficient because IT equipment is not cool enough whereas the server room is overcooled. Under these circumstances, the authors have proposed liquid cooling systems in which CPUs are cooled down directly and exhaust heat is not radiated into the server room. Three cooling technique for CPUs are developed simultaneously. Two of them involve a single-phase heat exchanger and a two-phase heat exchanger as a cooling jacket. The other is flat heat pipes in order that the heat generated by CPU is cooled after being transported to the outside of the chassis. Condensation section of the heat pipe is cooled down by liquid with liquid manifold, so that there is no air cooling part in our new liquid cooling systems. Performance evaluation tests of the cooling devices have been conducted, which are single-phase heat exchanger, two-phase heat exchanger and two-types of flat heat pipes. Meanwhile, nanofluid technology for heat transfer enhancement and development of plug-in connectors for standardization of the systems are pursued. In addition, Verification tests have been carried out with using commercial servers. As a result, a 44% to 53% reduction in energy consumption of cooling facilities with single-phase cooling system was realized compared with conventional air cooling system.
引用
收藏
页码:790 / 798
页数:9
相关论文
共 50 条
  • [21] Study of the Thermal Effectiveness of Laminar Forced Convection of Nanofluids for Liquid Cooling Applications
    Yu, Leyuan
    Liu, Dong
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2013, 3 (10): : 1693 - 1704
  • [22] A comprehensive review of novel cooling techniques and heat transfer coolant mediums investigated for battery thermal management systems in electric vehicles
    Youssef, Rekabra
    Kalogiannis, Theodoros
    Behi, Hamidreza
    Pirooz, Ashkan
    Van Mierlo, Joeri
    Berecibar, Maitane
    ENERGY REPORTS, 2023, 10 : 1041 - 1068
  • [23] A Systems Overview of Commercial Data Centers: Initial Energy and Cost Analysis
    Uzaman, Sardar Khaliq
    Khan, Atta ur Rehman
    Shuja, Junaid
    Maqsood, Tahir
    Rehman, Faisal
    Mustafa, Saad
    INTERNATIONAL JOURNAL OF INFORMATION TECHNOLOGY AND WEB ENGINEERING, 2019, 14 (01) : 42 - 65
  • [24] Battery thermal management systems: Recent progress and challenges
    Olabi A.G.
    Maghrabie H.M.
    Adhari O.H.K.
    Sayed E.T.
    Yousef B.A.A.
    Salameh T.
    Kamil M.
    Abdelkareem M.A.
    International Journal of Thermofluids, 2022, 15
  • [25] Thermal analysis on the impact of different velocity calculation methods for microchannel liquid cooling system in GPUs
    Praveen, S. M.
    Rammohan, A.
    ENGINEERING RESEARCH EXPRESS, 2025, 7 (01):
  • [26] Machine learning guided thermal management of Open Computing Language applications on CPU-GPU based embedded platforms
    Kumar, Rakesh
    Ghoshal, Bibhas
    IET COMPUTERS AND DIGITAL TECHNIQUES, 2023, 17 (01): : 20 - 28
  • [27] Airflow Management Using Active Air Dampers in Presence of a Dynamic Workload in Data Centers
    Khalili, Sadegh
    Mohsenian, Ghazal
    Desu, Anuroop
    Ghose, Kanad
    Sammakia, Bahgat
    2019 35TH SEMICONDUCTOR THERMAL MEASUREMENT, MODELING AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2019, : 101 - 110
  • [28] Stability, rheology and thermal analysis of functionalized alumina- thermal oil-based nanofluids for advanced cooling systems
    Ilyas, Suhaib Umer
    Pendyala, Rajashekhar
    Narahari, Marneni
    Susin, Lim
    ENERGY CONVERSION AND MANAGEMENT, 2017, 142 : 215 - 229
  • [29] Battery thermal management systems based on nanofluids for electric vehicles
    Abdelkareem, Mohammad Ali
    Maghrabie, Hussein M.
    Abo-Khalil, Ahmed G.
    Adhari, Ohood Hameed Kadhim
    Sayed, Enas Taha
    Radwan, Ali
    Elsaid, Khaled
    Wilberforce, Tabbi
    Olabi, A. G.
    JOURNAL OF ENERGY STORAGE, 2022, 50
  • [30] Energy and thermal performance of heat pipe/cooling coil systems in hot-humid climates
    Budaiwi, IM
    Abdou, AA
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2000, 24 (10) : 901 - 915