Prevention of False-Positive Results: Development of an HPTLC Autographic Assay for the Detection of Natural Tyrosinase Inhibitors

被引:35
|
作者
Taibon, Judith [1 ]
Ankli, Anita [2 ]
Schwaiger, Stefan [1 ]
Magnenat, Camille
Boka, Vasilik-Ioanna [4 ]
Simoes-Pires, Claudia [3 ]
Aligiannis, Naktarios [4 ]
Cuendet, Muriel [3 ]
Skaltsounis, Alexios-Leandros [4 ]
Reich, Eike [2 ]
Stuppner, Hermann [1 ]
机构
[1] Univ Innsbruck, Inst Pharm Pharmacognosy, CMBI, CCB, A-6020 Innsbruck, Austria
[2] CAMAG Lab, Muttenz, Switzerland
[3] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, Geneva, Switzerland
[4] Univ Athens, Fac Pharm, Dept Pharmacognosy & Nat Prod Chem, Athens, Greece
关键词
autographic assay; HPTLC-MS; tyrosinase inhibitors; false positive results; AGENTS; SKIN;
D O I
10.1055/s-0035-1546250
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
A simple and rapid high-performance thin-layer chromatography-based autographic assay was established to screen plant extracts for the presence of tyrosinase-inhibiting substances. Three mobile phases were selected for the chromatographic separation of different types of extracts. After development, the plate was sprayed with the substrate solution Levodopa followed by a solution of the enzyme tyrosinase. Several known tyrosinase inhibitors were tested simultaneously as positive controls. They were detected as white spots with white light in remission from the plate as well as with white light transmitted through the plate. Some of the investigated extracts included spots showing a different behaviour; some lipophilic substances appeared as white spots in white light remission but were black in white light transmission. This behaviour, which could lead to false-positive results, was due to poor wettability of the corresponding spots. False-positive results were eliminated by adding Triton X-100 to the Levodopa solution and drying the plate after 10 minutes incubation with a molecular sieve. Tyrosinase inhibitors can be clearly identified as white spots against a dark background in white light remission as well as in white light transmitted through the plate. The established high-performance thin-layer chromatography autographic assay was validated and can be used as a standard method for the detection of tyrosinase inhibitors in plant extracts without causing false-positive results.
引用
收藏
页码:1198 / 1204
页数:7
相关论文
共 2 条
  • [1] Comparison of 4th-Generation HIV Antigen/Antibody Combination Assay With 3rd-Generation HIV Antibody Assays for the Occurrence of False-Positive and False-Negative Results
    Muthukumar, Alagarraju
    Alatoom, Adnan
    Burns, Susan
    Ashmore, Jerry
    Kim, Anne
    Emerson, Brian
    Bannister, Edward
    Ansari, M. Qasim
    LABMEDICINE, 2015, 46 (02): : 84 - 89
  • [2] Risk assessment of false-positive quantitative real-time PCR results in food, due to detection of DNA originating from dead cells
    Wolffs, P
    Norling, B
    Rådström, P
    JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 60 (03) : 315 - 323