A comparison between radiochromic EBT2 film model and its predecessor EBT film model

被引:22
作者
Carrasco, M. A. [1 ]
Perucha, M. [1 ]
Luis, F. J. [1 ]
Baeza, M. [1 ]
Herrador, M. [1 ]
机构
[1] Virgen del Rocio Hosp Seville, Dept Med Phys, Seville, Spain
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2013年 / 29卷 / 04期
关键词
Radiochromic; EBT2; EBT; Film dosimetry; FLAT-BED SCANNER; ENERGY-DEPENDENCE; GAFCHROMIC FILM; DOSIMETRY; PHOTON; OPTIMIZATION; SYSTEM;
D O I
10.1016/j.ejmp.2012.05.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The manufacturer has introduced the new EBT2 film model so as to improve its predecessor, the EBT radiochromic film model. According to the manufacturer, some of its main advantages include a higher tolerance to light exposure and it can correct non-uniformity of the active layer thickness using a marker dye. However, the equivalence in uniformity between both models was questioned by some authors, and the asymmetrical configuration of layers of the EBT2 film model produces a new dependence on the film side being scanned (front and back orientation). In this study, the EBT2 radiochromic film model was compared with the EBT model and the new marker dye feature was assessed. We also compared this correction method with a pre-irradiated pixel value correction method. An Epson Expression 10000XL scanner in transmission mode was used to scan the films and the red channel response was analyzed. We confirmed the lower-measured signal dependence on the visible light exposure of the EBT2 film model. Differences in pixel values remained below 0.5% for a minimum of 15 days. In regard to the uniformity, similar results for EBT2 and EBT film models were obtained; in both cases inhomogeneity was found to be less than 1%, in relative pixel value from the mean. However, we found that the signal-to-noise ratio was reduced for low doses by 37% for old EBT2 batch and by 21% for new EBT2 batch compared to signal-to-noise ratio for EBT. The EBT2 film model's pixel value difference for the front and back orientation reached up to 1.0% in the red channel. Our results did not show a clear advantage between to use a pre-irradiated pixel value correction and to use the manufacturer's correction. (C) 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:412 / 422
页数:11
相关论文
共 40 条
[1]   Evaluation of EBT-2 model GAFCHROMIC™ film performance in water [J].
Aldelaijan, Saad ;
Devic, Slobodan ;
Mohammed, Huriyyah ;
Tomic, Nada ;
Liang, Li-Heng ;
DeBlois, Francois ;
Seuntjens, Jan .
MEDICAL PHYSICS, 2010, 37 (07) :3687-3693
[2]   A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT [J].
Andres, C. ;
del Castillo, A. ;
Tortosa, R. ;
Alonso, D. ;
Barquero, R. .
MEDICAL PHYSICS, 2010, 37 (12) :6271-6278
[3]   Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies [J].
Arjomandy, Bijan ;
Tailor, Ramesh ;
Anand, Aman ;
Sahoo, Narayan ;
Gillin, Michael ;
Prado, Karl ;
Vicic, Milos .
MEDICAL PHYSICS, 2010, 37 (05) :1942-1947
[4]   Dose and absorption spectra response of EBT2 Gafchromic film to high energy x-rays [J].
Butson, M. J. ;
Cheung, T. ;
Yu, P. K. N. ;
Alnawaf, H. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (04) :196-202
[5]   Energy response of the new EBT2 radiochromic film to x-ray radiation [J].
Butson, Martin J. ;
Yu, Peter K. N. ;
Cheung, Tsang ;
Alnawaf, Hani .
RADIATION MEASUREMENTS, 2010, 45 (07) :836-839
[6]   Post-irradiation colouration of Gafchromic EBT radiochromic film [J].
Cheung, T ;
Butson, MJ ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :N281-N285
[7]   The use of new GAFCHROMIC® EBT film for 125I seed dosimetry in Solid Water® phantom [J].
Chiu-Tsao, Sou-Tung ;
Medich, David ;
Munro, John, III .
MEDICAL PHYSICS, 2008, 35 (08) :3787-3799
[8]   Photon beam dosimetry in the superficial buildup region using radiochromic EBT film stack [J].
Chiu-Tsao, Sou-Tung ;
Chan, Maria F. .
MEDICAL PHYSICS, 2009, 36 (06) :2074-2083
[9]   Technical Note: Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry [J].
Desroches, Joannie ;
Bouchard, Hugo ;
Lacroix, Frederic .
MEDICAL PHYSICS, 2010, 37 (04) :1565-1570
[10]   Accurate skin dose measurements using radiochromic film in clinical applications [J].
Devic, S ;
Seuntjens, J ;
Abdel-Rahman, W ;
Evans, M ;
Olivares, M ;
Podgorsak, EB ;
Vuong, T ;
Soares, CG .
MEDICAL PHYSICS, 2006, 33 (04) :1116-1124