Attractive performance of a Gifford-McMahon cryocooler by co-axial layout of regenerator materials

被引:3
作者
Masuyama, Shinji [1 ]
Matsui, Kohei [1 ]
Tamura, Kota [1 ]
Numazawa, Takenori [2 ]
机构
[1] Oshima Natl Coll Maritime Technol, Yamaguchi, Japan
[2] Natl Inst Mat Sci, Tsukuba, Ibaraki, Japan
关键词
Gifford-McMahon cryocooler; Co-axial layout; Layer layout; Gd2O2S; HoCu2;
D O I
10.1016/j.cryogenics.2012.04.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel filling method of regenerator materials, which we name a co-axial layout, is experimentally investigated. The 2nd stage regenerator of a Gifford-McMahon cryocooler was packed with 50% by volume of the co-axial layout (low temperature side) that consisted of 20% Gd2O2S and 30% HoCu2 spheres. The warm temperature side was packed with 50% lead spheres as a single layer. The experimental results show that the cooling power of co-axial layout is almost the same as that of a three-layer layout, 20% Gd2O2S, 30% HoCu2 and 50% lead, at temperatures between the ultimate low temperature (3.0 K) and 6 K. Moreover, at the temperatures above 10 K, the co-axial layout has 1.7-2.0 times the cooling power of the three-layer layout. Thus the co-axial layout produces a major improvement in cooling power. In this paper, the performance of five types of material assortments is discussed. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:695 / 698
页数:4
相关论文
共 5 条
  • [1] Kuriyama T., 1990, Adv. Cryog. Eng, P1261, DOI [10.1007/978-1-4613-0639-9_150, DOI 10.1007/978-1-4613-0639-9_150]
  • [2] Characteristics of a 4 K Gifford-McMahon cryocooler using the Gd2O2S regenerator material
    Masuyam, Shinji
    Fukuda, Yusuke
    Imazu, Takuya
    Numazawa, Takenori
    [J]. CRYOGENICS, 2011, 51 (06) : 337 - 340
  • [3] Numazawa T., 2003, CRYOCOOLERS, V12, P473
  • [4] SAHASHI M, 1990, ADV CRYOGEN ENG, V35, P1175
  • [5] Satoh T., 2003, CRYOCOOLERS, V12, P397, DOI DOI 10.1007/0-306-47919-2_52