Aqueous shunts for glaucoma

被引:57
作者
Minckler, D. S. [1 ]
Vedula, S. S. [1 ]
Li, T. J. [1 ]
Mathew, M. C. [1 ]
Ayyala, R. S. [1 ]
Francis, B. A. [1 ]
机构
[1] Doheny Eye Inst, Dept Ophthalmol, Los Angeles, CA 90033 USA
来源
COCHRANE DATABASE OF SYSTEMATIC REVIEWS | 2006年 / 02期
关键词
D O I
10.1002/14651858.CD004918.pub2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Aqueous shunts are employed for intraocular pressure (IOP) control in primary and secondary glaucomas that fail medical, laser, and other surgical therapies. Objectives This review compares aqueous shunts for IOP control and safety. Search strategy We searched CENTRAL, MEDLINE, PubMed, EMBASE, NRR all in January 2006, LILACS to February 2004 and reference lists of included trials. Selection criteria We included all randomized and quasi-randomized trials in which one arm of the study involved shunts. Data collection and analysis Two authors independently extracted data for included studies and a third adjudicated discrepancies. We contacted investigators for missing information. We used fixed-effect models and summarized continuous outcomes using mean differences. Main results We included fifteen trials with a total of 1153 participants with mixed diagnoses. Five studies reported details sufficient to verify the method of randomization but only two had adequate allocation concealment. Data collection and follow-up times were variable. Meta-analysis of two trials comparing Ahmed implant with trabeculectomy found trabeculectomy resulted in lower mean IOPs 11 to 13 months later ( mean difference 3.81 mm Hg, 95% CI 1.94 to 5.69 mm Hg). Meta-analysis of two trials comparing double-plate Molteno implant with the Schocket shunt was not done due to substantial heterogeneity. One study comparing ridged with standard double-plate Molteno implants found no clinically significant differences in outcome. Two trials investigating the effectiveness of adjunctive mitomycin (MMC) with the Molteno and Ahmed implants found no evidence of bene fit with MMC. Two trials that investigated surgical technique variations with the Ahmed found no benefit with partial tube ligation or excision of Tenon's capsule. One study concluded there were outcome advantages with a double versus a single-plate Molteno implant and one trial comparing the 350 mm(2) and 500 mm(2) Baerveldt shunts found no clinically significant advantage of the larger device but neither of these trials included all patients randomized. One study suggested improved clinical outcome when MMC was employed with a newly described shunt including ultrasound supporting the conclusion. One small study did not demonstrate an outcome advantage to systemic steroid use postoperatively with single-plate Molteno shunts. One study comparing endocyclophotocoagulation (ECP) with Ahmed implant in complicated glaucomas found no evidence of better IOP control with Ahmed implant over ECP. Authors' conclusions Relatively few randomized trials have been published on aqueous shunts and methodology and data quality among them is poor. To date there is no evidence of superiority of one shunt over another.
引用
收藏
页数:45
相关论文
共 93 条
[1]  
ALLAN B, 1996, ADV GLAUCOMA FILTRAT
[2]  
Alward WLM, 1996, AM J OPHTHALMOL, V121, P349
[3]  
*ANSI, 1998, AM NAT STAND OPHTH A
[4]   Use of glaucoma drainage devices in the management of glaucoma associated with aniridia [J].
Arroyave, CP ;
Scott, IU ;
Gedde, SJ ;
Parrish, RK ;
Feuer, WJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (02) :155-159
[5]   A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma [J].
Ayyala, RS ;
Zurakowski, D ;
Smith, JA ;
Monshizadeh, R ;
Netland, PA ;
Richards, DW ;
Layden, WE .
OPHTHALMOLOGY, 1998, 105 (10) :1968-1976
[6]  
Ayyala RS, 2002, OPHTHALMIC SURG LAS, V33, P94
[7]   Aqueous shunt devices compared with trabeculectomy with mitomycin-C for children in the first two years of life [J].
Beck, AD ;
Freedman, S ;
Kammer, J ;
Jin, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (06) :994-1000
[8]   Retinal detachment in patients with a preexisting glaucoma drainage device - Anatomic, visual acuity, and intraocular pressure outcomes [J].
Benz, MS ;
Scott, IU ;
Flynn, HW ;
Gedde, SJ .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (03) :283-287
[9]   Randomized clinical trial of the 350-mm2 versus the 500-mm2 Baerveldt implant:: Longer term results -: Is bigger better? [J].
Britt, MT ;
LaBree, LD ;
Lloyd, MA ;
Minckler, DS ;
Heuer, DK ;
Baerveldt, G ;
Varma, R .
OPHTHALMOLOGY, 1999, 106 (12) :2312-2318
[10]   Combined Baerveldt glaucoma drainage implant and trabeculectomy with mitomycin C for refractory glaucoma [J].
Budenz, DL ;
Scott, IU ;
Nguyen, QH ;
Feuer, W ;
Singh, K ;
Nicolela, MT ;
Bueche, M ;
Palmberg, PF .
JOURNAL OF GLAUCOMA, 2002, 11 (05) :439-445