Early and late outcome after off-pump coronary artery bypass graft surgery with coronary endarterectomy: A single-center 10-year experience

被引:37
|
作者
Vohra, HA
Kanwar, R
Khan, T
Dimitri, WR [1 ]
机构
[1] Univ Hosp Coventry, Walsgrave Hosp, Dept Cardiothorac Surg, Coventry, W Midlands, England
[2] Univ Warwickshire NHS Trust, Walsgrave Hosp, Coventry, W Midlands, England
来源
ANNALS OF THORACIC SURGERY | 2006年 / 81卷 / 05期
关键词
D O I
10.1016/j.athoracsur.2005.12.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We aimed to review the early and late results of off- pump coronary artery bypass graft surgery ( OPCABG) with coronary endarterectomy in patients undergoing surgical revascularization at our institution. Methods. Between 1995 and 2004, of 680 OPCABG patients in a single surgeon's practice ( W. R. D.), 70 patients ( 10.29%) who underwent concomitant coronary endarterectomy were studied. The mean age was 63.6 +/- 9.29 years. Thirty- three patients ( 55%) were Canadian Cardiovascular Society class III or IV, and 24 patients ( 40%) were New York Heart Association class III or IV. Eighteen patients ( 35%) had impaired left ventricular function. The mean EuroSCORE of these patients was 5.9 +/- 1.8. Results. Fifty- seven patients ( 81%) underwent right coronary artery endarterectomy, and 12 patients ( 17%) underwent left anterior descending artery endarterectomy ( 8 left interior mammary arteries used as conduits). Four patients ( 5.7%) had two vessels endarterectomized. The mean number of grafts were 2.0 +/- 0.4. The 30- day mortality rate was 2.85% ( n = 2). Three patients ( 4.3%) suffered from postoperative myocardial infarction, and 3 patients ( 4.3%) required postoperative intra- aortic balloon pump counterpulsation. Mean intensive therapy unit stay was 17.6 +/- 8.1 hours. Patients were extubated after a mean of 10.38 +/- 4.9 hours. The mean length of hospital stay was 6.1 +/- 2.0 days. Fourteen patients ( 20%) had postoperative atrial fibrillation, and only 1 patient ( 1.42%) had a transient stroke with complete recovery. There were no conversions to cardiopulmonary bypass. A mean of 0.86 +/- 0.17 units of blood were transfused postoperatively. There was one reopening for bleeding, and 1 patient had renal failure requiring hemofiltration. The median follow- up was 4.91 years, 90% of patients were angina free, and the actuarial survival at 10 years was 78.04% +/- 7.6%. Conclusions. Off- pump coronary artery bypass graft survery with coronary endarterectomy is feasible and achieves surgical revascularization in patients with diffuse coronary artery disease.
引用
收藏
页码:1691 / 1696
页数:6
相关论文
共 50 条
  • [1] Coronary endarterectomy with off-pump coronary artery bypass surgery
    Eryilmaz, S
    Inan, MB
    Eren, NT
    Yazicioglu, L
    Corapcioglu, T
    Akalin, H
    ANNALS OF THORACIC SURGERY, 2003, 75 (03): : 865 - 869
  • [2] 10-year experience with off-pump coronary artery bypass surgery at the Heart Institute Lahr/Baden
    Albert, A.
    Ennker, J.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2007, 21 (06): : 259 - 265
  • [3] Total Arterial Off-Pump Coronary Artery Bypass Grafting: A 10-Year Experience
    Yuan, Biao
    Qi, Hong-Wei
    Zhao, Jian-Gang
    Wang, Xi-Zheng
    Chen, Nan
    Zhao, Feng-Hua
    Wang, Li-Fang
    Dong, Huan-Ping
    CHINESE MEDICAL JOURNAL, 2018, 131 (18) : 2179 - 2184
  • [4] Total Arterial Off-Pump Coronary Artery Bypass Grafting: A 10-Year Experience
    Yuan Biao
    Qi Hong-Wei
    Zhao Jian-Gang
    Wang Xi-Zheng
    Chen Nan
    Zhao Feng-Hua
    Wang Li-Fang
    Dong Huan-Ying
    中华医学杂志英文版, 2018, 131 (18) : 2179 - 2184
  • [5] Further reduction in stroke after off-pump coronary artery bypass grafting: A 10-year experience
    Trehan, N
    Mishra, M
    Sharma, OP
    Mishra, A
    Kasliwal, RR
    ANNALS OF THORACIC SURGERY, 2001, 72 (03): : S1026 - S1032
  • [6] Graft Patency After Off-Pump Coronary Artery Bypass Surgery
    Thourani, Vinod H.
    Guyton, Robert A.
    CIRCULATION, 2012, 125 (23) : 2806 - 2808
  • [7] Off-pump coronary artery bypass grafting: A single center experience
    Sajja L.R.
    Mannam G.C.
    Alluri R.G.R.
    Somapalli S.R.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2001, 17 (2) : 77 - 81
  • [8] Patency in off-pump coronary artery bypass graft surgery
    Zamvar, V
    HEART SURGERY FORUM, 2004, 7 (03): : E214 - E215
  • [9] Off-pump coronary artery bypass graft surgery - Response
    Maslow, A
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2000, 14 (05) : 624 - 625
  • [10] Comparison of outcome of off-pump coronary artery bypass surgery and conventional coronary artery bypass surgery
    Yu, HY
    Wu, IH
    Chen, YS
    Chi, NH
    Hsu, RB
    Tsai, C
    Wang, SS
    Lin, FY
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2003, 102 (08) : 556 - 562