Retro-fitting an older (S)TEM with two Cs aberration correctors for 80 kV and 60 kV operation

被引:16
作者
Boerrnert, F. [1 ]
Bachmatiuk, A. [1 ]
Gorantla, S. [1 ]
Wolf, D. [2 ]
Lubk, A. [2 ]
Buechner, B. [1 ]
Ruemmeli, M. H. [1 ]
机构
[1] IFW Dresden, D-01171 Dresden, Germany
[2] Tech Univ Dresden, Triebenberg Lab, D-01062 Dresden, Germany
关键词
Aberration correction; retro-fitting; STEM; TEM; TRANSMISSION ELECTRON-MICROSCOPY; PERFORMANCE; RESOLUTION; GRAPHENE; IRRADIATION; FUTURE; CARBON;
D O I
10.1111/j.1365-2818.2012.03684.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
For the characterization of light materials using transmission electron microscopy, a low electron acceleration voltage of 80 kV or even 60 kV is attractive due to reduced beam damage to the specimen. The concomitant reduction in resolving power of the microscope can be restored when using spherical aberration (Cs) correctors, which for the most part are only available in the latest and most expensive microscopes. Here, we show that upgrading of existing TEMs is an attractive and cost-effective alternative. We report on the low-voltage performance on graphitic material of a JEOL JEM-2010F built in the early 1990s and retro-fitted with a conventional imaging Cs corrector and a probe Cs corrector. The performance data show Cs retro-fitted instruments can compete very favourably against more modern state-of-the-art instruments in both conventional imaging (TEM) and scanning (STEM) modes.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 25 条
[1]   Quantification of the Information Limit of Transmission Electron Microscopes [J].
Barthel, J. ;
Thust, A. .
PHYSICAL REVIEW LETTERS, 2008, 101 (20)
[2]   Sub-Angstrom Low-Voltage Performance of a Monochromated, Aberration-Corrected Transmission Electron Microscope [J].
Bell, David C. ;
Russo, Christopher J. ;
Benner, Gerd .
MICROSCOPY AND MICROANALYSIS, 2010, 16 (04) :386-392
[3]   Amorphous Carbon under 80 kV Electron Irradiation: A Means to Make or Break Graphene [J].
Boerrnert, Felix ;
Avdoshenko, Stanislav M. ;
Bachmatiuk, Alicja ;
Ibrahim, Imad ;
Buechner, Bernd ;
Cuniberti, Gianaurelio ;
Ruemmeli, Mark H. .
ADVANCED MATERIALS, 2012, 24 (41) :5630-5635
[4]   Background, status and future of the Transmission Electron Aberration-corrected Microscope project [J].
Dahmen, Ulrich ;
Erni, Rolf ;
Radmilovic, Velimir ;
Kisielowski, Christian ;
Rossell, Marta-Dacil ;
Denes, Peter .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2009, 367 (1903) :3795-3808
[5]   Beam-induced damage to thin specimens in an intense electron probe [J].
Egerton, RF ;
Wang, F ;
Crozier, PA .
MICROSCOPY AND MICROANALYSIS, 2006, 12 (01) :65-71
[6]   Towards 0.1 nm resolution with the first spherically corrected transmission electron microscope [J].
Haider, M ;
Rose, H ;
Uhlemann, S ;
Kabius, B ;
Urban, K .
JOURNAL OF ELECTRON MICROSCOPY, 1998, 47 (05) :395-405
[7]   Estimation of suitable condition for observing copper-phthalocyanine crystalline film by transmission electron microscopy [J].
Hayashida, Misa ;
Kawasaki, Tadahiro ;
Kimura, Yoshihide ;
Takai, Yoshizo .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 248 (02) :273-278
[8]   A spherical a berration-corrected 200 kV TEM [J].
Hosokawa, F ;
Tomita, T ;
Naruse, M ;
Honda, T ;
Hartel, P ;
Haider, M .
JOURNAL OF ELECTRON MICROSCOPY, 2003, 52 (01) :3-10
[9]   A versatile double aberration-corrected, energy filtered HREM/STEM for materials science [J].
Hutchison, JL ;
Titchmarsh, JM ;
Cockayne, DJH ;
Doole, RC ;
Hetherington, CJD ;
Kirkland, AI ;
Sawada, H .
ULTRAMICROSCOPY, 2005, 103 (01) :7-15
[10]   Performance and early applications of a versatile double aberration-corrected JEOL-2200FS FEG TEM/STEM at Aalto University [J].
Jiang, Hua ;
Ruokolainen, Janne ;
Young, Neil ;
Oikawa, Tetsuo ;
Nasibulin, Albert G. ;
Kirkland, Angus ;
Kauppinen, Esko I. .
MICRON, 2012, 43 (04) :545-550