Measurement of breast density with digital breast tomosynthesis

被引:4
作者
Ren, Baorui [1 ]
Smith, Andrew [1 ]
Jing, Zhenxue [1 ]
机构
[1] Hologic Inc, Bedford, MA 01730 USA
来源
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING | 2012年 / 8313卷
关键词
Digital breast tomosynthesis; mammography; volumetric breast density; scatter correction; scatter response function; Quantra;
D O I
10.1117/12.913357
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Breast density is known as a strong risk factor for breast cancer. Clinical assessment of breast density during screening mammography is often done by radiologists through visual evaluation or by a computer program. Automated computer methods offer the potential for non-subjective density assessments. With the rapid development and increased utilization of tomosynthesis clinically, there is a practical need for systems to provide automated breast density measurements in tomosynthesis like those available in mammography. Quantra (TM) is a software package using physical modeling of mammography systems, and performs volumetric assessment of breast tissue composition for conventional mammography. In this paper, we describe recent developments to extend Quantra to calculate breast density using tomosynthesis projection images. Our development took advantage of the combo imaging mode of Hologic Selenia Dimensions (TM) system, which allowed co-registered conventional 2D mammogram and 3D tomosynthesis images to be acquired in a single compression. We used the Quantra results of 2D mammograms as a reference to refine the new processing algorithm for tomosynthesis images. This paper describes details of the new algorithm and provides some preliminary results.
引用
收藏
页数:6
相关论文
共 6 条
[1]   Breast percent density estimation from 3D reconstructed digital breast tomosynthesis images [J].
Bakic, Predrag R. ;
Kontos, Despina ;
Carton, Ann-Katherine ;
Maidment, Andrew D. A. .
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
[2]   Scatter/primary in mammography: Comprehensive results [J].
Boone, JM ;
Lindfors, KK ;
Cooper, VN ;
Seibert, JA .
MEDICAL PHYSICS, 2000, 27 (10) :2408-2416
[3]   Scatter/primary in mammography: Monte Carlo validation [J].
Boone, JM ;
Cooper, VN .
MEDICAL PHYSICS, 2000, 27 (08) :1818-1831
[4]   An edge spread technique for measurement of the scatter-to-primary ratio in mammography [J].
Cooper, VN ;
Boone, JM ;
Seibert, JA ;
Pellot-Barakat, CJ .
MEDICAL PHYSICS, 2000, 27 (05) :845-853
[5]   X-RAY SCATTER REMOVAL BY DECONVOLUTION [J].
SEIBERT, JA ;
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (04) :567-575
[6]  
Yaffe M., 2011, 5 INT WORKSH BREAST