"Home monitoring" for early detection of implantable cardioverter-defibrillator failure

被引:31
作者
Hauck, Melanie [1 ]
Bauer, Alexander [1 ]
Voss, Frederik [1 ]
Weretka, Slawomir [1 ]
Katus, Hugo A. [1 ]
Becker, Ruediger [1 ]
机构
[1] Univ Heidelberg, Dept Cardiol, D-69120 Heidelberg, Germany
关键词
telemedicine; implantable cardioverter-defibrillator; cardiac resynchronisation therapy; follow-up studies; ventricular arrhythmia; COMPLICATIONS; TELEMEDICINE; FUTURE; DEVICE;
D O I
10.1007/s00392-008-0712-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Telemedical ICD monitoring has the potential to enhance patient safety. The "home-monitoring" (HM) feature transmits selected device-related data to a service-center via mobile phone network. In case of a potential emergency situation, event reports are generated automatically. This prospective observational study was designed to test whether HM is effective and reliable in early detection of device failure. Consecutive patients receiving ICD, CRT-D or CRT pacemaker systems with HM feature were included. Regular follow-up visits were performed 1, 3, 6, 9 and 12 months after implantation in the first year, and every 6 months thereafter. All event reports transmitted by HM were analyzed and severe device-related events (serious lead or device dysfunction, hospitalization, death) were documented including timing, type and mode of detection. Sixty-nine patients were included and followed for 18 +/- A 9 months. A total of 206 event reports were transmitted, prompted by VF/VT-episodes (n = 193), ineffective ICD shocks (n = 7), abnormal pacing impedance (n = 4) or battery depletion (n = 2). 8 SAEs were observed (RV lead fracture; n = 5, connector defect; n = 1, sensing defect, n = 1, RV lead dislodgement, n = 1). There was no device-related death. 6 out of 8 SAEs were discovered by HM (sensitivity, 75%). Without HM, these events would have been detected with a theoretical delay of 1.9 +/- A 0.5 months in the first year (3 monthly FU) and 4.9 +/- A 0.5 months in the following years (6 monthly FU). This pilot study demonstrates that HM enables early detection of ICD failure and appears to enhance patient safety.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 19 条
[1]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[2]  
CHUN S, 2002, EUROPACE SA, V3, pA71
[3]   Home Monitoring: what can we expect in the future? [J].
Deharo, JC ;
Djiane, P .
CLINICAL RESEARCH IN CARDIOLOGY, 2006, 95 (Suppl 3) :36-39
[4]  
Elsner C.H., 2006, Comput Cardiol, V33, P241
[5]   Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients [J].
Fauchier, L ;
Sadoul, N ;
Kouakam, C ;
Briand, F ;
Chauvin, M ;
Babuty, D ;
Clementy, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 :S255-S259
[6]   SUDDEN-DEATH MORTALITY IN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR PATIENTS [J].
GROSS, J ;
ZILO, P ;
FERRICK, K ;
FISHER, JD ;
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :250-251
[7]  
Hohnloser SH, 2000, Z KARDIOL, V89, P136
[8]  
Koos R, 2005, Z KARDIOL, V94, P461, DOI 10.1007/s00392-005-0244-z
[9]   Lead- and device-related complications in the Antiarrhythmics versus implantable defibrillators trial [J].
Kron, J ;
Herre, J ;
Renfroe, EG ;
Rizo-Patron, C ;
Raitt, M ;
Halperin, B ;
Gold, M ;
Goldner, B ;
Wathen, M ;
Wilkoff, B ;
Olarte, A ;
Yao, Q .
AMERICAN HEART JOURNAL, 2001, 141 (01) :92-98
[10]  
Lamaison D, 2004, ARCH MAL COEUR VAISS, V97, P1160