In Vivo Evaluation of Carotid Artery Stents Using Multi-Detector-Row Computed Tomography Angiography: Comparison of 3 Kernels

被引:4
作者
Lee, Youn Joo [1 ]
Lim, Yeon Soo [1 ]
Jung, Na Young [1 ]
Yoo, Won Jong [1 ]
Sung, Mi Sook [1 ]
Chung, Myung Hee [1 ]
Kim, Bum Soo [2 ]
机构
[1] Catholic Univ Korea, Bucheon St Marys Hosp, Dept Radiol, Seoul, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Seoul, South Korea
关键词
carotid artery; stents; CT angiography; SMALL-VESSEL STENTS; CT ANGIOGRAPHY; INTRACRANIAL ANGIOPLASTY; VITRO EVALUATION;
D O I
10.1097/RCT.0b013e318289a9f9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to assess the lumen visibility of carotid artery stents using multi-detector-row computed tomography (MDCT) angiography; compare medium-smooth, medium-sharp, and sharp kernels; and correlate these results to those of digital subtraction angiography (DSA). Methods: We retrospectively evaluated 52 stents from 51 patients who underwent 16- and 64-slice MDCT angiography. Lumen diameters were measured 3 times by 2 neuroradiologists, and artificial luminal narrowing was calculated. To assess detection of in-stent restenosis (>50%), 2 neuroradiologists evaluated all MDCT and DSA images. Results: Excellent intraobserver and interobserver agreements were obtained for the lumen diameter measurements (P < 0.001). Lumen diameter visibility improved, and artificial luminal narrowing decreased from the medium-smooth kernel to the sharp kernel. Visual estimation of all CT angiography using the 3 kernels showed high accuracy for detection of in-stent restenosis (>50%), compared with DSA. Conclusions: Computed tomography angiography using a sharp kernel allows for more accurate assessment of lumen visibility after carotid artery stenting.
引用
收藏
页码:402 / 407
页数:6
相关论文
共 19 条
[1]   Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis [J].
Barnett, HJM ;
Taylor, W ;
Eliasziw, M ;
Fox, AJ ;
Ferguson, GG ;
Haynes, RB ;
Rankin, RN ;
Clagett, GP ;
Hachinski, VC ;
Sackett, DL ;
Thorpe, KE ;
Meldrum, HE ;
Spence, JD .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (20) :1415-1425
[2]  
Hähnel S, 2003, AM J NEURORADIOL, V24, P1512
[3]   Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings [J].
Heuschmid, Martin ;
Wiesinger, Benjamin ;
Tepe, Gunnar ;
Luz, Oliver ;
Kopp, Andreas F. ;
Claussen, Claus D. ;
Duda, Stephan H. .
EUROPEAN RADIOLOGY, 2007, 17 (01) :265-271
[4]   Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels [J].
Jang, Jin Hee ;
Lim, Yeon Soo ;
Lee, Youn Joo ;
Yoo, Won Jong ;
Sung, Mi Sook ;
Kim, Bum Soo .
ACTA RADIOLOGICA, 2012, 53 (04) :456-460
[5]   Noninvasive assessment of coronary stents in patients by 16-slice computed tomography [J].
Kitagawa, Toshiro ;
Fujii, Takashi ;
Tomohiro, Yasuyuki ;
Maeda, Kouji ;
Kobayashi, Masakazu ;
Kunita, Eiji ;
Sekiguchi, Yoshitaka .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 109 (02) :188-194
[6]   Dual-Source CT Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types [J].
Koehler, Michael ;
Burg, Matthias C. ;
Bunck, Alexander C. ;
Heindel, Walter ;
Seifarth, Harald ;
Maintz, David .
RADIOLOGY RESEARCH AND PRACTICE, 2011, 2011
[7]   In vitro comparison of different carotid artery stents: a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T [J].
Lettau, Michael ;
Sauer, Annett ;
Heiland, Sabine ;
Rohde, Stefan ;
Reinhardt, Julia ;
Bendszus, Martin ;
Haehnel, Stefan .
NEURORADIOLOGY, 2010, 52 (09) :823-830
[8]  
Maintz D, 2003, INVEST RADIOL, V38, P790, DOI 10.1097/01.rli.0000086495.96457.54
[9]   64-slice multidetector coronary CT angiography:: in vitro evaluation of 68 different stents [J].
Maintz, D ;
Seifarth, H ;
Raupach, R ;
Flohr, T ;
Rink, M ;
Sommer, T ;
Özgün, M ;
Heindel, W ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2006, 16 (04) :818-826
[10]   Carotid artery stenting and follow-up: Value of 64-MSCT angiography as complementary imaging method to color-coded duplex sonography [J].
Nolz, Richard ;
Wibmer, Andreas ;
Beitzke, Dietrich ;
Gentzsch, Stephan ;
Willfort-Ehringer, Andrea ;
Lammer, Johannes ;
Thurnher, Majda ;
Schoder, Maria .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) :89-94