Analysis of Uncertainty of Maximum of Electric Field in Reverberation Chamber

被引:0
作者
Zhou, Xiang [1 ]
Wang, Rongsheng [1 ]
机构
[1] Southeast Univ, Sch Mech Engn, Nanjing, Jiangsu, Peoples R China
来源
2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC) | 2016年
关键词
reverberation chamber; uncertainty; maximum of electric field; NUMBER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electromagnetic compatibility test in reverberation chamber has unique superiority. However, the problem of uncertainty on reverberation chamber testing is focused all the time. In some immunity test, the maximum of electric field is concerned. The standard deviation relative to mean value, the width of the confidence interval and the ratio of maximum and minimum value are used to describe the uncertainty of maximum of electric field. The effects of the number of independent samples on the uncertainty are analyzed. The results show that the uncertainty decreases with the increase of the number of independent samples, but the velocity is slow when the number is big. The ratio of maximum and minimum value can also be used to describe the stirrer efficiency.
引用
收藏
页码:1202 / 1204
页数:3
相关论文
共 10 条
[1]  
[Anonymous], 610004212011 IEC
[2]  
Arnaunt L. R., 2008, 2 NPL TQE
[3]   Measurement Uncertainty of Antenna Efficiency in a Reverberation Chamber [J].
Chen, Xiaoming .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2013, 55 (06) :1331-1334
[4]   Experimental Investigation of the Number of Independent Samples and the Measurement Uncertainty in a Reverberation Chamber [J].
Chen, Xiaoming .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2013, 55 (05) :816-824
[5]   On Independent Platform Sample Number for Reverberation Chamber Measurements [J].
Chen, Xiaoming .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2012, 54 (06) :1306-1309
[6]  
De Leo R., 2005, INSTR MEAS TECHN C 2, V1, P337
[7]   STATISTICAL-MODEL FOR A MODE-STIRRED CHAMBER [J].
KOSTAS, JG ;
BOVERIE, B .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1991, 33 (04) :366-370
[8]   Analysis of the Independent Positions of Reverberation Chamber Stirrers as a Function of Their Operating Conditions [J].
Moglie, Franco ;
Primiani, Valter Mariani .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2011, 53 (02) :288-295
[9]  
Wang C.M.J., 2014, ELECTROMAGNETIC COMP, V56, P1002
[10]  
Zhou X., 2005, THESIS