摘要
An analytical method based on gas chromatography-mass spectrometry (GC-MS) has been developed to determine non-volatile fraction of disinfection by-products (DBP) in drinking water. Solid phase extraction (SPE) with tri-methyl-ammonium chlorine (TMA-Cl) cartridges is followed by derivatization of desired analyte in the eluted extract. The studied factors are elution volume, methy-tertiary-butyl ether (MTBE) volume and derivatization time. Experimental design was used to investigate and subsequently used to optimize the elution volume of derivatizing agent (10% acidic methanol), MTBE volume and derivatization time for haloacetic acids (HAAs) extraction in the water sample. Regression models and desirability functions were applied to find an experimental setup for acquiring the highest global extraction yield of HAAs. The elution volume and derivatization time were the only statistically significant factors from this study. In the final optimized conditions, the procedure was applied to the SPE-GC-MS analysis of HAAs in water samples with better figures of merit. This modified method has advantage over the EPA method 552.1.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 24 条
[1]   The study of interrelationship between raw water quality parameters, chlorine demand and the formation of disinfection by-products [J].
Abdullah, Md. Pauzi ;
Yee, Lim Fang ;
Ata, Sadia ;
Abdullah, Abass ;
Ishak, Basar ;
Abidin, Khairul Nidzham Zainal .
PHYSICS AND CHEMISTRY OF THE EARTH, 2009, 34 (13-16) :806-811
[2]  
[Anonymous], 1959, Technometrics
[3]  
[Anonymous], 1993, GUID DRINK WAT QUAL
[4]   Development of a liquid-liquid extraction procedure for five 1,4-dihydropyridines calcium channel antagonists from human plasma using experimental design [J].
Baranda, AB ;
Etexbarria, N ;
Jiménez, RM ;
Alonso, RM .
TALANTA, 2005, 67 (05) :933-941
[5]   Doehlert matrix for optimisation of procedure for determination of nickel in saline oil-refinery effluents by use of flame atomic absorption spectrometry after preconcentration by cloud-point extraction [J].
Bezerra, MD ;
Conceiçao, ALB ;
Ferreira, SLC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (03) :798-803
[6]  
Brereton R.J., 1990, CHEMOMETRIC APPL MAT
[7]  
Clesceri L, 1998, STANDARD METHODS EXA
[8]   Homogeneous liquid-liquid extraction of trace amounts of mononitrotoluenes from waste water samples [J].
Ebrahimzadeh, Homeira ;
Yamini, Yadollah ;
Kamarei, Fahimeh ;
Shariati, Shahab .
ANALYTICA CHIMICA ACTA, 2007, 594 (01) :93-100
[9]   Box-Behnken design: An alternative for the optimization of analytical methods [J].
Ferreira, S. L. C. ;
Bruns, R. E. ;
Ferreira, H. S. ;
Matos, G. D. ;
David, J. M. ;
Brandao, G. C. ;
da Silva, E. G. P. ;
Portugal, L. A. ;
dos Reis, P. S. ;
Souza, A. S. ;
dos Santos, W. N. L. .
ANALYTICA CHIMICA ACTA, 2007, 597 (02) :179-186
[10]   Solid-phase extraction system for Pb (II) ions enrichment based on multiwall carbon nanotubes coupled on-line to flame atomic absorption spectrometry [J].
Francisco Barbosa, Adriano ;
Gava Segatelli, Mariana ;
Cesar Pereira, Arnaldo ;
de Santana Santos, Antonio ;
Tatsuo Kubota, Lauro ;
Orival Luccas, Pedro ;
Ricardo Teixeira Tarley, Cesar .
TALANTA, 2007, 71 (04) :1512-1519