Factors affecting the rate of false positive marks in CAD in full-field digital mammography

被引:4
作者
Engelken, Florian [1 ]
Bremme, Raphael
Bick, Ulrich [1 ]
Hammann-Kloss, Sophie
Fallenberg, Eva M. [1 ]
机构
[1] Charite, Dept Radiol, D-10117 Berlin, Germany
关键词
Mammography; Computer-aided detection; Specificity; Breast density; Fibroglandular tissue; COMPUTER-AIDED DETECTION; SCREENING MAMMOGRAPHY; BREAST DENSITY; CANCER-DETECTION; CARCINOMA; SENSITIVITY; PERFORMANCE; IMPACT;
D O I
10.1016/j.ejrad.2012.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess the effect of breast density, fibroglandular tissue volume, and breast volume on the rate of false-positive marks of a computer-assisted detection software in digital mammography. Materials and methods: 222 patients with normal digital mammograms and a minimum follow-up of 22 months were retrospectively identified. MLO and CC views were analyzed using a CAD software with three operating points ('specific', 'balanced', 'sensitive'). False-positive marks were recorded. Images were analyzed by a volumetric breast density assessment software, yielding estimates of percentage density, fibroglandular tissue volume, and breast volume. Statistical analysis was performed using the Mann-Whitney U-test, the t-test for independent samples and the Poisson regression model. Results: Patients with high fibroglandular tissue volumes had a higher mean number of false-positive mass marks than patients with low fibroglandular tissue volumes (specific setting: 0.50 vs. 0.35, respectively; balanced setting: 0.70 vs. 0.40, respectively, p < 0.05; sensitive setting: 0.89 vs. 0.58, respectively, p < 0.05). Relative risk for a false-positive mass marker increased by 1.43 (p < 0.05), 1.63 (p < 0.001) and 1.50 (p < 0.01) per 100 ml of fibroglandular tissue for the specific, balanced and sensitive settings, respectively. No significant effects of percentage density or breast volume on the number or the relative risk of false-positive mass marks were observed. Conclusion: The volume of fibroglandular tissue present, but not the percentage density of the breast, affected the specificity for masses of the CAD software investigated. This may have implications for improving the performance of CAD systems, as the specificity of CAD may be improved by adjusting the algorithm threshold depending on the volume of fibroglandular tissue present. Considering both factors, fibroglandular tissue volume and percentage density, independently, could improve overall CAD performance in subgroups of patients, e. g. those with small, dense breasts or large breasts with low density. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E844 / E848
页数:5
相关论文
共 20 条
[1]  
[Anonymous], 2009, UND R2 IMAGECHECKER
[2]  
[Anonymous], 2009, UND R2 QUANTR 1 3 MA
[3]   ANALYSIS OF CANCERS MISSED AT SCREENING MAMMOGRAPHY [J].
BIRD, RE ;
WALLACE, TW ;
YANKASKAS, BC .
RADIOLOGY, 1992, 184 (03) :613-617
[4]   Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection [J].
Birdwell, RL ;
Ikeda, DM ;
O'Shaughnessy, KF ;
Sickles, EA .
RADIOLOGY, 2001, 219 (01) :192-202
[5]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[6]   Impact of breast density on computer-aided detection for breast cancer [J].
Brem, RF ;
Hoffmeister, JW ;
Rapelyea, JA ;
Zisman, G ;
Mohtashemi, K ;
Jindal, G ;
DiSimio, MP ;
Rogers, SK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :439-444
[7]   Improvement in sensitivity of screening mammography with computer-aided detection: A multiinstitutional trial [J].
Brem, RF ;
Baum, J ;
Lechner, M ;
Kaplan, S ;
Souders, S ;
Naul, LG ;
Hoffmeister, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) :687-693
[8]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[9]   Evaluation of computer-aided detection systems in the detection of small invasive breast carcinoma [J].
Ellis, Richard L. ;
Meade, Andrew A. ;
Mathiason, Michelle A. ;
Willison, Kathy M. ;
Logan-Young, Wence .
RADIOLOGY, 2007, 245 (01) :88-94
[10]   Influence of computer-aided detection on performance of screening mammography [J].
Fenton, Joshua J. ;
Taplin, Stephen H. ;
Carney, Patricia A. ;
Abraham, Linn ;
Sickles, Edward A. ;
D'Orsi, Carl ;
Berns, Eric A. ;
Cutter, Gary ;
Hendrick, R. Edward ;
Barlow, William E. ;
Elmore, Joann G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (14) :1399-1409