Follow-up of coiled cerebral aneurysms at 3T: Comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography

被引:45
作者
Anzalone, N. [1 ]
Scomazzoni, F.
Cirillo, M.
Righi, C.
Simionato, F.
Cadioli, M.
Iadanza, A.
Kirchin, M. A. [2 ]
Scotti, G.
机构
[1] Osped San Raffaele, Dept Neuroradiol, Inst Sci, I-20132 Milan, Italy
[2] Bracco Imaging SpA, Worldwide Med & Regulatory Affairs, Milan, Italy
关键词
D O I
10.3174/ajnr.A1166
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Our aim was to compare contrast-enhanced MR angiography (CE-MRA) and 3D time-of-flight (TOF) MRA at 3T for follow-up of coiled cerebral aneurysms. MATERIALS AND METHODS: Fifty-two patients treated with Guglielmi detachable coils for 54 cerebral aneurysms were evaluated at 3T MRA. 3D TOF MRA (TR/TE = 23/3.5; SENSE factor = 2.5) and CE-MRA by using a 3D ultrafast gradient-echo sequence (TR/TE = 5.9/1.8; SENSE factor = 3) enhanced with 0.1-mmol/kg gadobenate dimeglumine were performed in the same session. Source images, 3D maximum intensity projection, 3D shaded surface display, and/or 3D volume-rendered reconstruct ions were evaluated in terms of aneurysm occlusion/patency and artifact presence. RESULTS: In terms of clinical classification, the 2 MRA sequences were equivalent for 53 of the 54 treated aneurysms: 21 were considered fully occluded, whereas 16 were considered to have a residual neck and 16 were considered residually patent at follow-up MRA. The remaining aneurysm appeared fully occluded at TOF MRA but had a residual patent neck at CE-MBA. Visualization of residual aneurysm patency was significantly (P = .001) better with CE-MRA compared with TOF MRA for 10 (31.3%) of the 32 treated aneurysms considered residually patent with both sequences. Coil artifacts were present in 5 cases at TOF MRA but in none at CE-MRA. No relationship was apparent between the visualization of patency and either the size of the aneurysm or the interval between embolization and follow-up. CONCLUSION: At follow-up MRA at 3T, unenhanced TOF and CE-MRA sequences are similarly effective at classifying coiled aneurysms as occluded or residually patent. However, CE-MRA is superior to TOF MRA for visualization of residual patency and is associated with fewer artifacts.
引用
收藏
页码:1530 / 1536
页数:7
相关论文
共 45 条
[1]  
Anzalone N, 2000, AM J NEURORADIOL, V21, P746
[2]   Follow-up of coiled cerebral aneurysms: Comparison of three-dimensional time-of-flight magnetic resonance angiography at 3 tesla with three-dimensional time-of-flight magnetic resonance angiography and contrast-enhanced magnetic resonance angiography at 1.5 tesla [J].
Anzalone, Nicoletta ;
Scomazzoni, Francesco ;
Cirillo, Mario ;
Cadioli, Marcello ;
Iadanza, Antonella ;
Kirchin, Miles A. ;
Scotti, Giuseppe .
INVESTIGATIVE RADIOLOGY, 2008, 43 (08) :559-567
[3]   Follow-up of intracranial aneurysms treated with detachable coils: Comparison of gadolinium-enhanced 3D time-of-flight MR angiography and digital subtraction angiography [J].
Boulin, A ;
Pierot, L .
RADIOLOGY, 2001, 219 (01) :108-113
[4]   Gadolinium chelates with weak binding to serum proteins - A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging [J].
Cavagna, FM ;
Maggioni, F ;
Castelli, PM ;
Dapra, M ;
Imperatori, LG ;
Lorusso, V ;
Jenkins, BG .
INVESTIGATIVE RADIOLOGY, 1997, 32 (12) :780-796
[5]   Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils [J].
Cognard, C ;
Weill, A ;
Spelle, L ;
Piotin, M ;
Castaings, L ;
Rey, A ;
Moret, J .
RADIOLOGY, 1999, 212 (02) :348-356
[6]  
Cottier JP, 2003, AM J NEURORADIOL, V24, P1797
[7]  
Derdeyn CP, 1997, AM J NEURORADIOL, V18, P279
[8]  
Deutschmann HA, 2007, AM J NEURORADIOL, V28, P628
[9]   Surveillance of intracranial aneurysms treated with detachable coils: a comparison of MRA techniques [J].
Farb, RI ;
Nag, S ;
Scott, JN ;
Willinsky, RA ;
Marotta, TR ;
Montanera, WJ ;
Tomlinson, G ;
terBrugge, KG .
NEURORADIOLOGY, 2005, 47 (07) :507-515
[10]  
Gauvrit JY, 2005, AM J NEURORADIOL, V26, P515