Pulmonary Perfused Blood Volume with Dual-Energy CT as Surrogate for Pulmonary Perfusion Assessed with Dynamic Multidetector CT

被引:117
作者
Fuld, Matthew K. [1 ,3 ]
Halaweish, Ahmed F. [1 ,3 ]
Haynes, Susan E. [4 ]
Divekar, Abhay A. [1 ,4 ]
Guo, Junfeng [1 ]
Hoffman, Eric A. [1 ,2 ,3 ]
机构
[1] Univ Iowa, Carver Coll Med, Dept Radiol, Iowa City, IA 52241 USA
[2] Univ Iowa, Carver Coll Med, Dept Med, Iowa City, IA 52241 USA
[3] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52241 USA
[4] Univ Iowa, Childrens Hosp, Div Pediat Cardiol, Dept Pediat, Iowa City, IA 52241 USA
基金
美国国家卫生研究院;
关键词
COMPUTED-TOMOGRAPHY; LUNG PERFUSION; FLOW; ANGIOGRAPHY; EMBOLISM;
D O I
10.1148/radiol.12112789
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare measurements of regional pulmonary perfused blood volume (PBV) and pulmonary blood flow (PBF) obtained with computed tomography (CT) in two pig models. Materials and Methods: The institutional animal care and use committee approved all animal studies. CT-derived PBF and PBV were determined in four anesthetized, mechanically ventilated, supine swine by using two methods for creating pulmonary parenchymal perfusion heterogeneity. Two animals were examined after sequentially moving a pulmonary arterial balloon catheter from a distal to a central location, and two others were examined over a range of static airway pressures, which varied the extents of regional PBF. Lung sections were divided into blocks and Pearson correlation coefficients calculated to compare matching regions between the two methods. Results: CT-derived PBF, CT-derived PBV, and their associated coefficients of variation (CV) were closely correlated on a region-by-region basis in both the balloon occlusion (Pearson R = 0.91 and 0.73 for animals 1 and 2, respectively; Pearson R = 0.98 and 0.87 for comparison of normalized mean and CV for animals 1 and 2, respectively) and lung inflation studies (Pearson R = 0.94 and 0.74 for animals 3 and 4, respectively; Pearson R = 0.94 and 0.69 for normalized mean and CV for animals 3 and 4, respectively). When accounting for region-based effects, correlations remained highly significant at the P <. 001 level. Conclusion: CT-derived PBV heterogeneity is a suitable surrogate for CT-derived PBF heterogeneity.
引用
收藏
页码:747 / 756
页数:10
相关论文
共 20 条
[1]   Heterogeneity of pulmonary perfusion as a mechanistic image-based phenotype in emphysema susceptible smokers [J].
Alford, Sara K. ;
van Beek, Edwin J. R. ;
McLennan, Geoffrey ;
Hoffman, Eric A. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (16) :7485-7490
[2]  
Brown M., 2010, IMAGING MED, V2, P565
[3]   Regional pulmonary blood flow in dogs by 4D-X-ray CT [J].
Chon, Deokiee ;
Beck, Kenneth C. ;
Larsen, Ranae L. ;
Shikata, Hidenori ;
Hoffman, Eric A. .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 101 (05) :1451-1465
[4]  
COURNAND A, 1950, J THORAC SURG, V19, P80
[5]   DMechanism of Hypoxemia in acute lung injury evaluated by multidetector-row CT [J].
Easley, RB ;
Fuld, MK ;
Fernandez-Bustamante, A ;
Hoffman, EA ;
Simon, BA .
ACADEMIC RADIOLOGY, 2006, 13 (07) :916-921
[6]   Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution [J].
Ferda, Jiri ;
Ferdova, Eva ;
Mirka, Hynek ;
Baxa, Jan ;
Bednarova, Alena ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Matejovic, Martin ;
Kreuzberg, Boris .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (02) :287-293
[7]  
Guo J, 2008, P 1 INT WORKSH PULM, P283
[8]   Dual-energy CT angiography of the lungs: Comparison of test bolus and bolus tracking techniques for the determination of scan delay [J].
Henzler, Thomas ;
Meyer, Mathias ;
Reichert, Miriam ;
Krissak, Radko ;
Nance, John W., Jr. ;
Haneder, Stefan ;
Schoenberg, Stefan O. ;
Fink, Christian .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) :132-138
[9]  
Simon Brett A, 2005, Proc Am Thorac Soc, V2, P517, DOI 10.1513/pats.200603-086MS
[10]  
Kravchuk O, 2011, AM J RESP CRIT CA S1, V183, pA5202