Photocatalytic oxidation of VOCs at ppb level using a closed-loop reactor: The mixture effect

被引:76
作者
Hequet, V. [1 ]
Raillard, C. [1 ]
Debono, O. [1 ,2 ]
Thevenet, F. [2 ]
Locoge, N. [2 ]
Le Coq, L. [1 ]
机构
[1] UMR CNRS 6144, GEPEA, IMT Atlant, F-44307 Nantes, France
[2] Univ Lille, SAGE, IMT Lille Douai, F-59500 Douai, France
关键词
Photocatalysis; VOC mixture; Toluene; n-decane; TCE; ppb level; Indoor air; Reaction intermediates; Multi-pass closed-loop reactor; GAS-PHASE; INDOOR ENVIRONMENT; RELATIVE-HUMIDITY; TITANIUM-DIOXIDE; TRICHLOROETHYLENE; TOLUENE; TIO2; DEGRADATION; MINERALIZATION; FORMALDEHYDE;
D O I
10.1016/j.apcatb.2017.12.041
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An investigation of the photocatalytic degradation of indoor air model pollutants: toluene, n-decane and trichloroethylene (TCE), as single contaminants and in a mixture is proposed. The degradation of these contaminants was performed in a continuous closed-loop reactor operating in recirculation mode. Degradations were conducted at ppb level concentrations and under humid conditions (RH = 50%) in order to be closer to real applications of photocatalytic oxidation (PCO) systems developed for indoor air quality improvement. Accurate analytical methods were developed to identify and quantify the majority of the potential formed intermediates. Kinetic constants and the time constant of degradation were obtained for the model pollutants. Under these conditions, the degradation of the three VOCs in a mixture did not really show a decrease in the kinetic rates. Toluene and decane degradations were slightly slowed down when they were in a mixture but no significant interference was demonstrated with TCE. The intermediates formed during the PCO of the mixture of VOCs were the same as those identified during single degradation, leading to the hypothesis of few interactions between them. Only the formation and degradation of secondary intermediates, mostly composed of aldehydes, were time delayed. The total VOC concentration may lead to a competitive adsorption that seemed more sensitive for the last formed oxygenated intermediates. This investigation points out the need to always monitor the last formed aldehyde intermediates. Monitoring acetaldehyde and formaldehyde enables an evaluation of the efficiency and a better design of future PCO systems for indoor applications.
引用
收藏
页码:473 / 486
页数:14
相关论文
共 41 条
[11]   Key parameters influencing the performance of photocatalytic oxidation (PCO) air purification under realistic indoor conditions [J].
Destaillats, Hugo ;
Sleiman, Mohamad ;
Sullivan, Douglas P. ;
Jacquiod, Catherine ;
Sablayrolles, Jean ;
Molins, Laurent .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2012, 128 :159-170
[12]   Trichloroethylene-promoted photocatalytic oxidation of air contaminants [J].
dHennezel, O ;
Ollis, DF .
JOURNAL OF CATALYSIS, 1997, 167 (01) :118-126
[13]   Determination of the Clean Air Delivery Rate (CADR) of Photocatalytic Oxidation (PCO) Purifiers for Indoor Air Pollutants Using a Closed-Loop Reactor. Part I: Theoretical Considerations [J].
Dumont, Eric ;
Hequet, Valerie .
MOLECULES, 2017, 22 (03)
[14]   Influence of relative humidity on the photocatalytic oxidation (PCO) of toluene by TiO2 loaded on activated carbon fibers:: PCO rate and intermediates accumulation [J].
Guo, Ting ;
Bai, Zhipeng ;
Wu, Can ;
Zhu, Tan .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2008, 79 (02) :171-178
[15]   Gas-phase heterogeneous photocatalytic oxidation of chlorinated ethenes over titanium dioxide: perchloroethene [J].
Hegedus, M ;
Dombi, A .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2004, 53 (03) :141-151
[16]   Determination of the Clean Air Delivery Rate (CADR) of Photocatalytic Oxidation (PCO) Purifiers for Indoor Air Pollutants Using a Closed-Loop Reactor. Part II: Experimental Results [J].
Hequet, Valerie ;
Batault, Frederic ;
Raillard, Cecile ;
Thevenet, Frederic ;
Le Coq, Laurence ;
Dumont, Eric .
MOLECULES, 2017, 22 (03)
[17]   Performance of ultraviolet photocatalytic oxidation for indoor air cleaning applications [J].
Hodgson, A. I. ;
Destaillats, H. ;
Sullivan, D. P. ;
Fisk, W. J. .
INDOOR AIR, 2007, 17 (04) :305-316
[18]  
Hodgson AT., 2003, VOLATILE ORGANIC COM
[19]   Chemical adsorption of phosgene on TiO2 and its effect on the photocatalytic oxidation of trichloroethylene [J].
Joung, SK ;
Amemiya, T ;
Murabayashi, M ;
Cai, R ;
Itoh, K .
SURFACE SCIENCE, 2005, 598 (1-3) :174-184
[20]   Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong [J].
Lee, SC ;
Guo, H ;
Li, WM ;
Chan, LY .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (12) :1929-1940