Visual function after implantation of single-piece toric hydrophilic acrylic intraocular lenses with hydrophobic surface six months after cataract surgery

被引:0
|
作者
Crnej, Alja [2 ]
Pfeifer, Vladimir [1 ]
机构
[1] UKC Ljubljana, Ocesna Klin, Ljubljana 1000, Slovenia
[2] OKC Dr Pfeifer, Ljubljana, Slovenia
关键词
toric intraocular lens; cataract; visual function; astigmatism; cornea; ROTATIONAL STABILITY; ASTIGMATISM CORRECTION; CAPSULAR BAG; SHRINKAGE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: To assess visual function of the eyes with corneal astigmatism higher than 1D after cataract surgery and implantation of a single-piece plate-haptic toric hydrophilic acrylic intraocular lens with hydrophobic surface six months postoperatively. Methods: Patients with cataracts and corneal astigmatism higher than 1D were included into this prospective study. Predictive axis of IOL was marked on the cornea, standard phacoemulsification cataract surgery was performed and single-piece toric hydrophilic acrylic intraocular lens with hydrophobic surface was implanted into the lens capsule. Corneal astigmatism was measured pre- and postoperatively. Best-uncorrected and corrected distance visual acuity and change in axis orientation of astigmatism were measured postoperatively. Results: 34 eyes of 26 patients were included into this study. Mean best distance-uncorrected visual acuity in logMAR was 0.07 (SD:0.11), mean best distance-corrected visual acuity was -0.01 (SD:0.06), mean astigmatism of the eyes was 0.47 D (SD:0.35). Mean corneal astigmatism pre and postoperatively, was 2.50 D (SD:1.60) and 2.47 D (SD:1.60), respectively. The astigmatism axis of the eyes has changed on average 3.6 degrees (SD:3.3 degrees). Conclusion: Patients with medium to high corneal astigmatism and implanted single-piece toric hydrophilic acrylic IOLs with hydrophobic surface have very good visual function six months postoperatively.
引用
收藏
页码:I40 / I44
页数:5
相关论文
共 50 条
  • [1] Glistenings in the single-piece, hydrophobic, acrylic intraocular lenses
    Waite, Aaron
    Faulkner, Nathan
    Olson, Randall J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (01) : 143 - 144
  • [2] Rotational stability of two single-piece toric acrylic intraocular lenses
    Steinwender, Gernot
    Ardjomand, Navid
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [3] Haptic tuck for reverse optic capture of a single-piece acrylic toric or other single-piece acrylic intraocular lenses
    Gimbel, Howard V.
    Marzouk, Hala A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (02): : 125 - 129
  • [4] Sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsular rupture in cataract surgery
    Renieri, Giulia
    Herzog, Daniel
    Niemann, Stefan
    Becker, Matthias
    Kurz, Sabine
    Thieme, Hagen
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (06) : 950 - 955
  • [5] Ocular aberrations after cataract surgery with hydrophobic and hydrophilic acrylic intraocular lenses - Comparative study
    Rohart, Charlotte
    Lemarinel, Beatrice
    Hoang-Xuan, Thanh
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (07): : 1201 - 1205
  • [6] Pigment release and secondary glaucoma after implantation of single-piece acrylic intraocular lenses in the ciliary sulcus
    Uy, Harvey Siy
    Chan, Pik Sha T.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (02) : 330 - 332
  • [7] Intraoperative explantation of two single-piece hydrophobic acrylic intraocular lenses due to surface deposits
    M S Hickman
    L Werner
    N Mamalis
    E Sung
    D Goldstein
    D T Vroman
    S K Pandey
    Eye, 2006, 20 : 1054 - 1060
  • [8] Intraoperative explantation of two single-piece hydrophobic acrylic intraocular lenses due to surface deposits
    Hickman, M. S.
    Werner, L.
    Mamalis, N.
    Sung, E.
    Goldstein, D.
    Vroman, D. T.
    Pandey, S. K.
    EYE, 2006, 20 (09) : 1054 - 1060
  • [9] Opacification of two hydrophilic acrylic intraocular lenses 3 months after implantation
    Macky, TA
    Werner, L
    Soliman, MM
    Pandey, SK
    Izak, AM
    Apple, DJ
    OPHTHALMIC SURGERY LASERS & IMAGING, 2003, 34 (03): : 197 - 202
  • [10] A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses
    Wallin, TR
    Hinckley, M
    Nilson, C
    Olson, RJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (04) : 614 - 619