Low energy dosimetry with photon counting pixel detectors such as Medipix

被引:0
作者
Michel, Thilo [1 ]
Boehnel, Michael [1 ]
Durst, Juergen [1 ]
Anton, Gisela [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Phys, D-91058 Erlangen, Germany
来源
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11 | 2007年
关键词
Medipix; dosimetry; photon counting detector; dose equivalent;
D O I
10.1109/NSSMIC.2007.4436560
中图分类号
O59 [应用物理学];
学科分类号
摘要
The use of a semiconductor photon counting pixel detector like the Medipix detector [1] [2] in a dosimeter offers the possibility to take the photon energy dependence of the personal dose equivalents especially in the low energy range below 50 keV into account Furthermore the measuring range can be extended down to low photon energies of about 10 keV. In this contribution we restrict our considerations to the medical diagnostic energy range from 10 to 150 keV. Due to the fact that the sensitive area of the Medipix detector is relatively large with (1.41cm)(2) while the sensitive area of one pixel is small with (55 mu m)(2), it is able to measure very low dose rates with high statistical precision while still processing each photon even at high dose rates. In this contribution we explain a metho to determine personal dose equivalents from photon counted data, present measurement results of the air-kerma for different X-ray qualities and show simulation results of the performance of a dosimeter based on a hybrid photon counting pixel detector. We outline the advantages and perspectives of using a photon counting pixel detector in a dosimeter.
引用
收藏
页码:2070 / 2073
页数:4
相关论文
共 7 条
[1]   Imaging theory for X-ray pixel detectors [J].
Anton, G ;
Durst, J ;
Firsching, M ;
Giersch, J ;
Korn, A ;
Mitschke, M ;
Niederlhöner, D ;
Pfeiffer, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :116-123
[2]   ROSI - an object-oriented and parallel-computing Monte Carlo simulation for X-ray imaging [J].
Giersch, J ;
Weidemann, A ;
Anton, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :151-156
[3]   Data acquisition and processing software package for Medipix2 [J].
Holy, T ;
Jakubek, J ;
Pospisil, S ;
Uher, J ;
Vavrik, D ;
Vykydal, Z .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :254-258
[4]  
ICRU, 1998, 57 ICRU
[5]  
*IEC, 61526 IEC
[6]   Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode [J].
Llopart, X ;
Campbell, M ;
Dinapoli, R ;
Segundo, DS ;
Pemigotti, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2279-2283
[7]   Simulation of signal generation processes in semiconductor sensor layers for Medipix1 and 2 [J].
Mitschke, M ;
Giersch, J ;
Anton, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2) :62-67