摘要
Objective: To determine whether there were differences in the cross-sectional area (CSA) and the flattening ratio of the normative ulnar nerve as it passes between the medial epicondyle and the olecranon at 30 degrees of elbow flexion versus 90 degrees of elbow flexion. Design: Bilateral upper extremities of normal Dial healthy adult volunteers' were evaluated with ultrasound. The CSA and the flattening ratio of the ulnar nerve at the elbow as it passes between the medial epicondyle and the olecranon were measured, with the elbow flexed at 30 degrees and at 90 degrees, by 2 operators with varying ultrasound scanning experience by using ellipse and direct tracing methods. The results from the 2 different angles of elbow flexion were compared for each individual operator. Finally, intraclass correlations for absolute agreement and consistency between the 2 raters were calculated. Setting: An outpatient clinic room at a regional rehabilitation center. Participants: Twenty-five normal. healthy adult volunteers. Main Outcome Measurement: The mean CSA and the mean flattening ratio of the ulnar nerve at 30 degrees of elbow flexion and at 90 degrees of elbow flexion. Results: First, for the ellipse method, the mean CSA of the ulnar nerve at 90 degrees (9.93 mm(2)) was slightly larger than at 30 degrees (9.77 mm(2)) for rater 1. However, for rater 2, the mean CSA of the ulnar nerve at 90 degrees (6.80 mm(2)) was slightly smaller than at 30 degrees (7.08 mm(2)). This was found to be statistically insignificant when using a matched pairs t test and the Wilcoxon signed-rank test, with a significance level of .05. Similarly, the difference between the right side and the left side was not statistically significant. The intraclass correlations for absolute agreement between the 2 raters were not very high due to different measurement locations, but the intraclass correlations for consistency were high. Second, for the direct tracing method, the mean CSA at 90 degrees (7.26 mm(2)) was slightly lower than at 30 degrees (7.48 mm(2)). This was found to be statistically nonsignificant when using the matched pairs t test and the Wilcoxon signed-rank test with a significance level of .05. There was no significant difference in the average flattening ratio between the 2 angles for the left arm (0.54 at 30 degrees vs 0.56 at 90 degrees; P = .619 for the matched pairs t test and .274 for the Wilcoxon signed-rank test). However, for the right arm, the flattening ratio at 90 degrees was significantly higher than that at 30 degrees (0.58 at 90 degrees vs 0.50 at 30 degrees; P = .007 for both the matched pairs t test and the Wilcoxon signed-rank test). Conclusions: The mean CSA of the ulnar nerve at the elbow at 30 degrees was not significantly different than at 90 degrees. However, the average flattening ratio at 90 degrees was found to be significantly higher than at 30 degrees for the right arm.
引用
收藏
页码:395 / 399
页数:5
相关论文
共 50 条
  • [41] Snapping ulnar nerve at the elbow: A case report and review of the literature
    Dincer, Recep
    Baykal, Y. Barbaros
    Atay, Tolga
    Duran, K. Cagler
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2020, 11 (05): : 536 - 539
  • [42] DOPPLER SONOGRAPHY FOR ULNAR NEUROPATHY AT THE ELBOW
    Cheng, Yi
    Xu, Xiuyue
    Chen, Weimin
    Wang, Yi
    MUSCLE & NERVE, 2016, 54 (02) : 258 - 263
  • [43] NORMATIVE VALUES FOR SHORT-SEGMENT NERVE CONDUCTION STUDIES AND ULTRASONOGRAPHY OF THE ULNAR NERVE AT THE ELBOW
    Omejec, Gregor
    Podnar, Simon
    MUSCLE & NERVE, 2015, 51 (03) : 370 - 377
  • [44] The High-Resolution Ultrasonography and Electrophysiological Studies in Nerve Decompression for Ulnar Nerve Entrapment at the Elbow
    Zhong, Wenxiang
    Zhang, Wenchuan
    Zheng, Xuesheng
    Li, Shiting
    Shi, Jun
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2012, 28 (05) : 345 - 348
  • [45] Utility of nerve conduction studies and ultrasonography in ulnar neuropathies at the elbow of different severity
    Omejec, Gregor
    Podnar, Simon
    CLINICAL NEUROPHYSIOLOGY, 2020, 131 (07) : 1672 - 1677
  • [46] Arthroscopic Ulnar Nerve Decompression in the Setting of Elbow Osteoarthritis
    Kovachevich, Rudy
    Steinmann, Scott P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (04): : 663 - 668
  • [47] Subluxation of the ulnar nerve in the elbow region - Ultrasonographic evaluation
    Grechenig, W
    Mayr, J
    Peicha, G
    Boldin, C
    ACTA RADIOLOGICA, 2003, 44 (06) : 662 - 664
  • [48] Endoscopic ulnar nerve release at the elbow: Indications and outcomes
    Marcheix, P. -S.
    Vergnenegre, G.
    Chevalier, C.
    Hardy, J.
    Charissoux, J. -L.
    Mabit, C.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) : 41 - 45
  • [49] Ultrasound biomechanical anatomy of the soft structures in relation to the ulnar nerve in the cubital tunnel of the elbow
    Michelin, Paul
    Leleup, Gregoire
    Ould-Slimane, Mourad
    Merlet, Marie Caroline
    Dubourg, Benjamin
    Duparc, Fabrice
    SURGICAL AND RADIOLOGIC ANATOMY, 2017, 39 (11) : 1215 - 1221
  • [50] Evaluation and Treatment of Failed Ulnar Nerve Release at the Elbow
    Nellans, Kate
    Tang, Peter
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2012, 43 (04) : 487 - +