Pre- and postoperative offset and femoral neck version measurements and validation using 3D computed tomography in total hip arthroplasty

被引:7
|
作者
Geijer, Mats [1 ,2 ,3 ]
Kiernan, Sverrir [4 ,5 ]
Sundberg, Martin [4 ,5 ]
Flivik, Gunnar [4 ,5 ]
机构
[1] Univ Gothenburg, Dept Radiol, Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Radiol, Bruna Straket 11 B,Plan 02, S-41345 Gothenburg, Sweden
[3] Lund Univ, Dept Clin Sci, Lund, Sweden
[4] Lund Univ, Dept Orthoped, Clin Sci, Lund, Sweden
[5] Skane Univ Hosp, Lund, Sweden
关键词
Hip arthroplasty; femoral neck anteversion; femoral offset; acetabular offset; proximal femoral symmetry; 3D-measurements; ANTEVERSION; RADIOGRAPHS; AGREEMENT; ANGLE;
D O I
10.1177/2058460120964911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Restoration of a correct biomechanical situation after total hip arthroplasty is important. Purpose: To evaluate proximal femoral symmetry of acetabular and femoral offset and femoral neck anteversion pre- and postoperatively in hip arthroplasty by semi-automated 3D-CT and to validate the software measurements by inter- and intraobserver agreement calculations. Material and Methods: In low-dose CT on 71 patients before and after unilateral total hip arthroplasty, two observers used a digital 3D templating software to measure acetabular offset, true and functional femoral offset, and femoral neck anteversion. Observer agreements were calculated using intraclass correlation. Hip measurements were compared in each patient and between pre- and postoperative measurements. Results: Preoperatively, acetabular offset (2.4 mm), true (2.2 mm), and functional global offset (2.7 mm) were significantly larger on the osteoarthritic side without side-to-side differences for true and functional femoral offset or femoral neck anteversion. Postoperatively, acetabular offset was significantly smaller on the operated side (2.1 mm) with a concomitantly increased true (2.5 mm) and functional femoral offset (1.5 mm), resulting in symmetric true and functional global offsets. There were no differences in postoperative femoral neck anteversion. Inter- and intraobserver agreements were near-perfect, ranging between 0.92 and 0.98 with narrow confidence intervals (0.77-0.98 to 0.94-0.99). Conclusion: Acetabular and concomitantly global offset are generally increased in hip osteoarthritis. Postoperative acetabular offset was reduced, and femoral offset increased to maintain global offset. 3D measurements were reproducible with near-perfect observer agreements. 3D data sets should be used for pre- and postoperative measurements in hip arthroplasty.
引用
收藏
页数:10
相关论文
共 8 条
  • [1] Computed tomography-based automated 3D measurement of femoral version: Validation against standard 2D measurements in symptomatic patients
    Schmaranzer, Florian
    Movahhedi, Mohammadreza
    Singh, Mallika
    Kallini, Jennifer R.
    Nanavati, Andreas K.
    Steppacher, Simon D.
    Heimann, Alexander F.
    Kiapour, Ata M.
    Novais, Eduardo N.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (10) : 2237 - 2248
  • [2] Anatomical study based on 3D-CT image reconstruction of the hip rotation center and femoral offset in a Chinese population: preoperative implications in total hip arthroplasty
    Yi, Lin-hong
    Li, Rui
    Zhu, Zheng-ya
    Bai, Chao-wen
    Tang, Jin-long
    Zhao, Feng-chao
    Zheng, Xin
    Guo, Kai-jin
    SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (01) : 117 - 124
  • [3] Fractured morphology of femoral head associated with subsequent femoral neck fracture: Injury analyses of 2D and 3D models of femoral head fractures with computed tomography
    Wu, Shenghui
    Wang, Wei
    Li, Ruiyang
    Guo, Jingyi
    Miao, Yu
    Li, Guangyi
    Mei, Jiong
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [4] Reliability of a New Method for Evaluating Femoral Stem Positioning After Total Hip Arthroplasty Based on Stereoradiographic 3D Reconstruction
    Guenoun, Benjamin
    El Hajj, Firass
    Biau, David
    Anract, Philippe
    Courpied, Jean-Pierre
    JOURNAL OF ARTHROPLASTY, 2015, 30 (01) : 141 - 144
  • [5] The final implant position of a commonly used collarless straight tapered stem design (Corail®) does not correlate with femoral neck resection height in cement-free total hip arthroplasty: a retrospective computed tomography analysis
    Worlicek, Michael
    Weber, Markus
    Woerner, Michael
    Schwarz, Timo
    Zeman, Florian
    Grifka, Joachim
    Renkawitz, Tobias
    Craiovan, Benjamin
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2018, 19 (01)
  • [6] Can Computed Tomography Accurately Measure Acetabular Anterversion in Developmental Dysplasia of the Hip? Verification and Characterization Using 3D Printing Technology
    Cai, Zhencun
    Zhao, Qun
    Li, Lianyong
    Zhang, Lijun
    Ji, Shijun
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2018, 38 (04) : E180 - E185
  • [7] The final implant position of a commonly used collarless straight tapered stem design (Corail®) does not correlate with femoral neck resection height in cement-free total hip arthroplasty: a retrospective computed tomography analysis
    Michael Worlicek
    Markus Weber
    Michael Wörner
    Timo Schwarz
    Florian Zeman
    Joachim Grifka
    Tobias Renkawitz
    Benjamin Craiovan
    Journal of Orthopaedics and Traumatology, 2018, 19
  • [8] Reproducible metacarpal joint space width measurements using 3D analysis of images acquired with high-resolution peripheral quantitative computed tomography
    Barnabe, Cheryl
    Buie, Helen
    Kan, Michelle
    Szabo, Eva
    Barr, Susan G.
    Martin, Liam
    Boyd, Steven K.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (10) : 1540 - 1544