Comparative study on off-design characteristics of CHP based on GTCC under alternative operating strategy for gas turbine

被引:23
作者
Yang, Cheng [1 ]
Huang, Zhifeng [2 ]
Ma, Xiaoqian [1 ]
机构
[1] South China Univ Technol, Sch Elect Power, Guangzhou 510640, Guangdong, Peoples R China
[2] CSG Power Generat Co, Maintenance & Test Ctr, Guangzhou 511400, Guangdong, Peoples R China
关键词
Combined cycle; Gas turbine; Combined heating and power (CHP); Stage-stacking; Off-design; COMBINED-CYCLE; CCHP; PERFORMANCE; OPTIMIZATION; SYSTEM; ENERGY; SIMULATION; MODEL; HEAT; FLOW;
D O I
10.1016/j.energy.2017.12.145
中图分类号
O414.1 [热力学];
学科分类号
摘要
As the rising proportion of natural gas in China energy structure, gas-steam combined cycle based CHP (combined heating and power) systems are expected to have wider applications. To study the performance of CHP systems under two different operating strategies, i.e., IGV (inlet guide vanes) strategy and TIT (turbine inlet temperature) strategy, a stage-stacking method was used for axial-flow compressor characteristics, a stage-by-stage model including blade cooling was adopted for the turbine, and analytical method was employed to solve HRSG (heat recovery steam generator) part-load performance. The model was validated by the field data from an existing MPCP1-M701F3 gas-steam combined cycle power unit. Maximum and minimum steam extraction lines for heating supply were obtained. The selection of operating point between the two lines to meet the same heating demand was discussed from the views of economic benefit and energy utilization efficiency. The results show that, compared to TIT strategy, CHP system with IGV strategy shows advantages in PES (primary energy saving) and total energy utilization efficiency whereas disadvantages in heat to power ratio under part-load conditions. Otherwise, for the same operating range of TIT, CHP system with IGV strategy can reach broader performance at the same steam extraction ratio. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:823 / 838
页数:16
相关论文
共 33 条
[1]   Selection based on differences between cogeneration and trigeneration in various prime mover technologies [J].
Al Moussawi, Houssein ;
Fardoun, Farouk ;
Louahlia, Hasna .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 74 :491-511
[2]  
[Anonymous], 2021, REV WORLD EN
[3]   Thermodynamic property models for moist air and combustion gases [J].
Bücker, D ;
Span, R ;
Wagner, W .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2003, 125 (01) :374-384
[4]  
Cooper J.R, 2007, Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam
[5]  
Dugan J.F.J., 1965, AERODYNAMIC DESIGN A, P469
[6]   Haze, public health and mitigation measures in China: A review of the current evidence for further policy response [J].
Gao, Jinghong ;
Woodward, Alistair ;
Vardoulakis, Sotiris ;
Kovats, Sari ;
Wilkinson, Paul ;
Li, Liping ;
Xu, Lei ;
Li, Jing ;
Yang, Jun ;
Li, Jing ;
Cao, Lina ;
Liu, Xiaobo ;
Wu, Haixia ;
Liu, Qiyong .
SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 578 :148-157
[7]  
General Electric Energy, 2005, GAS TURB COMB CYCL P
[8]   Methodology to analyze combined heat and power plant operation considering electricity reserve market opportunities [J].
Haakana, Juha ;
Tikka, Ville ;
Lassila, Jukka ;
Partanen, Jarmo .
ENERGY, 2017, 127 :408-418
[9]   Variable geometry gas turbines for improving the part-load performance of marine combined cycles - Combined cycle performance [J].
Haglind, F. .
APPLIED THERMAL ENGINEERING, 2011, 31 (04) :467-476
[10]   Variable geometry gas turbines for improving the part-load performance of marine combined cycles - Gas turbine performance [J].
Haglind, F. .
ENERGY, 2010, 35 (02) :562-570