Energy optimization of air conditioning system using hydrosolar roof as a heat sink

被引:3
作者
Lucas, M
Kaiser, AS
Viedma, A
Zamora, B
机构
[1] Univ Miguel Hernandez, Dept Ingn Sistemas Ind, Elche 03202, Spain
[2] Univ Politecn Cartagena, Dept Ingn Term & Fluidos, Cartagena 30202, Spain
关键词
drop size; air conditioning; solar chimney; cooling tower; solar energy;
D O I
10.1016/j.solener.2005.05.012
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An environmentally friendly alternative device, called hydrosolar roof, designed for heat dissipation in buildings has been integrated into a standard air conditioning system. To perform an energy consumption optimization it has been necessary to include all the elements in a global model. Then, three main subsystems have been considered: cooling machine, hydraulic network and hydrosolar roof. A description of the three subsystems is done and the mathematical model is presented. The cooling machine thermodynamic model has been carried out using EES (engineering equation solver). The hydraulic network model has piping, pump and nozzle information. The hydrosolar roof direct contact heat and mass transfer simulation has been developed with a CFD code. Special attention has been paid on the cooling efficiency. The global model has been applied to a real prototype facility experimentally tested. All the energy consumptions have been calculated for different pumping heads. A global coefficient of performance (COP) has been defined and the optimum value obtained. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:448 / 458
页数:11
相关论文
共 22 条
[1]   Optimization of a solar driven adsorption refrigeration system [J].
Alam, KCA ;
Saha, BB ;
Akisawa, A ;
Kashiwagi, T .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (06) :741-753
[2]  
[Anonymous], 1982, INT J REFRIG
[3]  
ASHRAE, 1997, ASHRAE Handbook SI (Fundamentals)
[4]   Solar refrigeration and cooling [J].
Best, R ;
Ortega, N .
RENEWABLE ENERGY, 1999, 16 (1-4) :685-690
[5]  
BRAUN JE, 1990, ASHRAE TRAN, V96, P806
[6]  
Cassidy M.P., 1988, ANN PETR CHEM IND C
[7]   Evaporative cooling of water in a mechanical draft cooling tower [J].
Fisenko, SP ;
Brin, AA ;
Petruchik, AI .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (01) :165-177
[8]   Review of solar and low energy cooling technologies for buildings [J].
Florides, GA ;
Tassou, SA ;
Kalogirou, SA ;
Wrobel, LC .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2002, 6 (06) :557-572
[9]   HVAC system optimization - condenser water loop [J].
Lu, L ;
Cai, WJ ;
Soh, YC ;
Xie, LH ;
Li, SJ .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (04) :613-630
[10]   Improved hydrosolar roof for buildings' air conditioning [J].
Lucas, M ;
Martínez, P ;
Sánchez, A ;
Viedma, A ;
Zamora, B .
ENERGY AND BUILDINGS, 2003, 35 (09) :963-970