Outcomes of stent optimisation in intravascular ultrasound-guided interventions for long lesions or chronic total occlusions

被引:13
|
作者
Kim, Daehoon [1 ]
Hong, Sung-Jin [1 ]
Kim, Byeong-Keuk [1 ,2 ]
Shin, Dong-Ho [1 ,2 ]
Ahn, Chul-Min [1 ,2 ]
Kim, Jung-Sun [1 ,2 ]
Ko, Young-Guk [1 ,2 ]
Choi, Donghoon [1 ,2 ]
Hong, Myeong-Ki [1 ,2 ,3 ]
Jang, Yangsoo [1 ,2 ,3 ]
机构
[1] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Div Cardiol,Dept Internal Med, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Cardiovasc Res Inst, Seoul, South Korea
[3] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul, South Korea
关键词
diffuse disease; drug-eluting stent; intravascular ultrasound; DRUG-ELUTING STENTS; ANGIOGRAPHIC RESTENOSIS; CLINICAL-OUTCOMES; IMPLANTATION; METAANALYSIS; IVUS; CALCIFICATION; GUIDANCE; IMPACT; TRIAL;
D O I
10.4244/EIJ-D-19-00762
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: We sought to investigate the incidence, predictors, and clinical outcomes of stent optimisation with intravascular ultrasound (IVUS) in long coronary lesions treated with new-generation drug-eluting stents (DESs). Methods and results: From four randomised trials comparing IVUS and angiography guidance in long (>= 26 mm) or chronic total occlusion coronary lesions, a total of 1,396 patients who underwent IVUS-guided intervention were classified into two groups (stent optimisation and non-optimisation) according to optimisation criteria (minimal stent area [MSA] >= 5.5 mm(2) or 80% of mean reference lumen area [MLA]). Major adverse cardiac event (MACE) occurrence, defined as a composite of cardiac death, myocardial infarction, stent thrombosis, or target vessel revascularisation, was compared. Stent optimisation was not met in 578 (41%) patients. Predictors of non-optimisation were older age, longer lesion length, and smaller stent diameter. The MACE rate was significantly higher in the non-optimisation versus the stent optimisation group (4.8% vs 1.9%, log-rank p=0.002; adjusted hazard ratio 2.95, 95% CI: 1.43-6.06). Among possible combinations of absolute and relative expansion criteria, the one best predicting MACE was at least one of MSA >= 5.4 mm(2) and/or >= 80% of MLA (Youden index=0.264). Conclusions: Achieving stent optimisation using IVUS evaluation was associated with favourable outcomes in IVUS-guided, new-generation DES implantation for long coronary lesions including CTOs.
引用
收藏
页码:E480 / +
页数:14
相关论文
共 50 条
  • [41] Impact of intravascular ultrasound-guided drug-eluting stent implantation on patients with chronic kidney disease: Results from ULTIMATE trial
    Zhang, Junjie
    Gao, Xiaofei
    Ge, Zhen
    Han, Leng
    Lu, Shu
    Qian, Xuesong
    Li, Qihua
    Lu, Qinghua
    Chen, Chonghao
    Chen, Shao-Liang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (07) : 1184 - 1193
  • [42] Intravascular Ultrasound-Guided Percutaneous Coronary Interventions An Ongoing Odyssey?
    Raeber, Lorenz
    Windecker, Stephan
    CIRCULATION, 2014, 129 (04) : 417 - 419
  • [43] Determinants of slow flow following stent implantation in intravascular ultrasound-guided primary percutaneous coronary intervention
    Watanabe, Yusuke
    Sakakura, Kenichi
    Taniguchi, Yousuke
    Yamamoto, Kei
    Wada, Hiroshi
    Fujita, Hideo
    Momomura, Shin-ichi
    HEART AND VESSELS, 2018, 33 (03) : 226 - 238
  • [44] Intravascular Imaging Use in Percutaneous Coronary Interventions of Chronic Total Occlusions
    Karacsonyi, Judit
    Kostantinis, Spyridon
    Simsek, Bahadir
    Basir, Mir
    Megaly, Michael
    Ali, Ziad
    Kirtane, Ajay
    Mcentegart, Margaret
    Brilakis, Emmanouil S.
    Alaswad, Khaldoon
    JOURNAL OF INVASIVE CARDIOLOGY, 2023, 35 (05) : E265 - E268
  • [45] Optical coherence omography-guided versus intravascular ultrasound-guided rotational atherectomy in patients with calcified coronary lesions
    Kobayashi, Norihiro
    Ito, Yoshiaki
    Yamawaki, Masahiro
    Araki, Motoharu
    Obokata, Masaru
    Sakamoto, Yasunari
    Mori, Shinsuke
    Tsutsumi, Masakazu
    Honda, Yohsuke
    Makino, Kenji
    Shirai, Shigemitsu
    Mizusawa, Masafumi
    Hirano, Keisuke
    EUROINTERVENTION, 2020, 16 (04) : E313 - E321
  • [46] Intravascular ultrasound-guided balloon angioplasty for treatment of in-stent restenosis
    Sakamoto, T
    Kawarabayashi, T
    Taguchi, H
    Tanaka, A
    Nishida, Y
    Shimada, K
    Yoshikawa, J
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 1999, 47 (03) : 298 - 303
  • [47] Patients With Chronic Total Occlusions Undergoing Percutaneous Coronary Interventions Characteristics, Success, and Outcomes
    Hannan, Edward L.
    Zhong, Ye
    Jacobs, Alice K.
    Stamato, Nicholas J.
    Berger, Peter B.
    Walford, Gary
    Sharma, Samin
    Venditti, Ferdinand J.
    King, Spencer B., III
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (05)
  • [48] Restenosis rate after intravascular ultrasound-guided coronary stent implantation
    Blasini, R
    Neumann, FJ
    Schmitt, C
    Walter, H
    Schomig, A
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 44 (04): : 380 - 386
  • [49] Outcomes of Intravascular Ultrasound-Guided Percutaneous Coronary Intervention Among Patients With Acute Coronary Syndrome
    Shafi, Irfan
    Patel, Dhruvil Ashishkumar
    Osman, Heba
    Patel, Neel
    Ramaseshan, Karthik
    Goel, Mishita
    Alraies, M. Chadi
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 204 : 115 - 121
  • [50] Intravascular ultrasound-guided percutaneous coronary intervention for patients with unprotected left main coronary artery lesions
    Bendary, Ahmed
    Elsaed, Ahmed
    Tabl, Mohamed Abdelshafy
    ElRabat, Khaled Ahmed
    Zarif, Bassem
    CORONARY ARTERY DISEASE, 2024, 35 (03) : 171 - 178