Preliminary experience with the multisensor HeartLogic algorithm for heart failure monitoring: a retrospective case series report

被引:51
作者
Capucci, Alessandro [1 ]
Santini, Luca [2 ]
Favale, Stefano [3 ]
Pecora, Domenico [4 ]
Petracci, Barbara [5 ]
Calo, Leonardo [6 ]
Molon, Giulio [7 ]
Cipolletta, Laura [1 ]
Bianchi, Valter [8 ]
Schirripa, Valentina [2 ]
Santobuono, Vincenzo E. [3 ]
La Greca, Carmelo [4 ]
Campari, Monica [9 ]
Valsecchi, Sergio [9 ]
Ammirati, Fabrizio [2 ]
D'Onofrio, Antonio [8 ]
机构
[1] Univ Politecn Marche, Clin Cardiol & Aritmol, Osped Riuniti, Via Conca 71, I-60020 Ancona, Italy
[2] Giovan Battista Grassi Hosp, Rome, Italy
[3] Univ Bari, Policlin Bari, Bari, Italy
[4] Fdn Poliambulanza, Brescia, Italy
[5] Fdn Policlin S Matteo IRCCS, Pavia, Italy
[6] Policlin Casilino, Rome, Italy
[7] Sacro Cuore Don Calabria Hosp, Verona, Italy
[8] Monaldi Hosp, Unita Operat Elettrofisiol Studio & Terapla Aritm, Naples, Italy
[9] Boston Sci Italia, Milan, Italy
关键词
ICD; CRT; Decompensation; Heart failure; Telemedicine;
D O I
10.1002/ehf2.12394
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims In the Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients study, a novel algorithm for heart failure (HF) monitoring was implemented. The HeartLogic (Boston Scientific) index combines data from multiple implantable cardioverter defibrillator (ICD)-based sensors and has proved to be a sensitive and timely predictor of impending HF decompensation. The remote monitoring of HF patients by means of Heartlogic has never been described in clinical practice. We report post-implantation data collected from sensors, the combined index, and their association with clinical events during follow-up in a group of patients who received a HeartLogic-enabled device in clinical practice. Methods and results Patients with ICD and cardiac resynchronization therapy ICD were remotely monitored. In December 2017, the Heartlogic feature was activated on the remote monitoring platform, and multiple ICD-based sensor data collected since device implantation were made available: Heartlogic index, heart rate, heart sounds, thoracic impedance, respiration, and activity. Their association with clinical events was retrospectively analysed. Data from 58 patients were analysed. During a mean follow-up of 5 +/- 3 months, the HeartLogic index crossed the threshold value (set by default to 16) 24 times (over 24 person-years, 0.99 alerts/patient-year) in 16 patients. HeartLogic alerts preceded five HF hospitalizations and five unplanned in-office visits for HF. Symptoms or signs of HF were also reported at the time of five scheduled visits. The median early warning time and the time spent in alert were longer in the case of hospitalizations than in the case of minor events of clinical deterioration of HF. Heartlogic contributing sensors detected changes in heart sound amplitude (increased third sound and decreased first sound) in all cases of alerts. Patients with Heartlogic alerts during the observation period had higher New York Heart Association class (P = 0.025) and lower ejection fraction (P = 0.016) at the time of activation. Conclusions Our retrospective analysis indicates that the HeartLogic algorithm might be useful to detect gradual worsening of HF and to stratify risk of HF decompensation.
引用
收藏
页码:308 / 318
页数:11
相关论文
共 12 条
[1]  
[Anonymous], MULT CARD SENS MAN H
[2]   A Multisensor Algorithm Predicts Heart Failure Events in Patients With Implanted Devices Results From the MultiSENSE Study [J].
Boehmer, John P. ;
Hariharan, Ramesh ;
Devecchi, Fausto G. ;
Smith, Andrew L. ;
Molon, Giulio ;
Capucci, Alessandro ;
An, Qi ;
Averina, Viktoria ;
Stolen, Craig M. ;
Thakur, Pramodsingh H. ;
Thompson, Julie A. ;
Wariar, Ramesh ;
Zhang, Yi ;
Singh, Jagmeet P. .
JACC-HEART FAILURE, 2017, 5 (03) :216-225
[3]   Effects of remote monitoring on clinical outcomes and use of healthcare resources in heart failure patients with biventricular defibrillators: results of the MORE-CARE multicentre randomized controlled trial [J].
Boriani, Giuseppe ;
Da Costa, Antoine ;
Quesada, Aurelio ;
Ricci, Renato Pietro ;
Favale, Stefano ;
Boscolo, Gabriele ;
Clementy, Nicolas ;
Amori, Valentina ;
Stefano, Lorenza Mangoni di S. ;
Burri, Haran .
EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 (03) :416-425
[4]   Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial [J].
Conraads, Viviane M. ;
Tavazzi, Luigi ;
Santini, Massimo ;
Oliva, Fabrizio ;
Gerritse, Bart ;
Yu, Cheuk-Man ;
Cowie, Martin R. .
EUROPEAN HEART JOURNAL, 2011, 32 (18) :2266-2273
[5]   Long-term monitoring of respiratory rate in patients with heart failure: the Multiparametric Heart Failure Evaluation in Implantable Cardioverter-Defibrillator Patients (MULTITUDE-HF) study [J].
Forleo, Giovanni B. ;
Santini, Luca ;
Campoli, Massimiliano ;
Malavasi, Mario ;
Scaccia, Alberto ;
Menichelli, Maurizio ;
Riva, Umberto ;
Lamberti, Filippo ;
Carreras, Giovanni ;
Orazi, Serafino ;
Ribatti, Valentina ;
Di Biase, Luigi ;
Lovecchio, Mariolina ;
Natale, Andrea ;
Valsecchi, Sergio ;
Romeo, Francesco .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 43 (02) :135-144
[6]   HeartLogic Multisensor Algorithm Identifies Patients During Periods of Significantly Increased Risk of Heart Failure Events Results From the MultiSENSE Study [J].
Gardner, Roy S. ;
Singh, Jagmeet P. ;
Stancak, Branislav ;
Nair, Devi G. ;
Cao, Michael ;
Schulze, Christopher ;
Thakur, Pramodsingh H. ;
An, Qi ;
Wehrenberg, Scott ;
Hammill, Eric F. ;
Zhang, Yi ;
Boehmer, John P. .
CIRCULATION-HEART FAILURE, 2018, 11 (07)
[7]   Daily remotemonitoring of implantable cardioverter-defibrillators: insights from the pooled patient-level data from three randomized controlled trials (IN-TIME, ECOST, TRUST) [J].
Hindricks, Gerhard ;
Varma, Niraj ;
Kacet, Salem ;
Lewalter, Thorsten ;
Sogaard, Peter ;
Guedon-Moreau, Laurence ;
Proff, Jochen ;
Gerds, Thomas A. ;
Anker, Stefan D. ;
Torp-Pedersen, Christian .
EUROPEAN HEART JOURNAL, 2017, 38 (22) :1749-1755
[8]   Remote management of heart failure using implantable electronic devices [J].
Morgan, John M. ;
Kitt, Sue ;
Gill, Jas ;
McComb, Janet M. ;
Ng, Ghulam Andre ;
Raftery, James ;
Roderick, Paul ;
Seed, Alison ;
Williams, Simon G. ;
Witte, Klaus K. ;
Wright, David Jay ;
Harris, Scott ;
Cowie, Martin R. .
EUROPEAN HEART JOURNAL, 2017, 38 (30) :2352-2360
[9]   2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure [J].
Ponikowski, Piotr ;
Voors, Adriaan A. ;
Anker, Stefan D. ;
Bueno, Hector ;
Cleland, John G. F. ;
Coats, Andrew J. S. ;
Falk, Volkmar ;
Ramon Gonzalez-Juanatey, Jose ;
Harjola, Veli-Pekka ;
Jankowska, Ewa A. ;
Jessup, Mariell ;
Linde, Cecilia ;
Nihoyannopoulos, Petros ;
Parissis, John T. ;
Pieske, Burkert ;
Riley, Jillian P. ;
Rosano, Giuseppe M. C. ;
Ruilope, Luis M. ;
Ruschitzka, Frank ;
Rutten, Frans H. ;
van der Meer, Peter .
EUROPEAN HEART JOURNAL, 2016, 37 (27) :2129-U130
[10]   Haemodynamic monitoring of cardiac status using heart sounds from an implanted cardiac device [J].
Thakur, Pramodsingh H. ;
An, Qi ;
Swanson, Lynne ;
Zhang, Yi ;
Gardner, Roy S. .
ESC HEART FAILURE, 2017, 4 (04) :605-613