Alignment of dynamic cardiac PET images for correction of motion

被引:25
|
作者
Turkington, TG
DeGrado, TR
Hanson, MW
Coleman, RE
机构
[1] Department of Radiology, Duke University Medical Center, Durham
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.568814
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A technique was developed to align images from dynamic cardiac N-13 ammonia positron emission tomography (PET) scans, Inaccurate alignment of images from these scans stems from breathing, motion of the heart within the thorax, and overall motion of the patient (particularly during pharmacologic stress), The images from these scans represent changing distributions, from high blood pool concentrations to predominantly myocardial uptake, and are generally noisy, In this technique, templates are defined from a long, late frame (5-10 min), These templates include a myocardial template, which matches late frames, a blood pool template, which matches frames in which the left ventricle blood pool is dominant, and a modified blood pool template, which reduces the effect of activity in the right ventricle. The correlation function is used as the maximized parameter over shifts between each three-dimensional image frame and the appropriate template, The technique was tested on phantom, human, and animal data with myocardial defects, Phantom data showed the technique to be reliable to within one voxel (1.7 x 1.7 x 4.2 mm(3)), and motion which was apparent in human data was reduced significantly, Blood flow values measured from corrected data showed two traits: higher values, due to better matching regions of interest to images, and better fits, due to smoother time-activity curves.
引用
收藏
页码:235 / 242
页数:8
相关论文
共 50 条
  • [1] Rescued diagnostic quality by motion correction of dynamic cardiac positron emission tomography (PET) perfusion images
    Thompson, Andrea D.
    Ficaro, Edward P.
    Murthy, Venkatesh L.
    Weinberg, Richard L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (01) : 330 - 332
  • [2] Rescued diagnostic quality by motion correction of dynamic cardiac positron emission tomography (PET) perfusion images
    Andrea D. Thompson
    Edward P. Ficaro
    Venkatesh L. Murthy
    Richard L. Weinberg
    Journal of Nuclear Cardiology, 2019, 26 : 330 - 332
  • [3] CT based motion correction of dual gated cardiac PET images
    Klen, Riku
    Noponen, Tommi
    Koikkalainen, Juha
    Lotjonen, Jyrki
    Thielemans, Kris
    Hoppela, Erika
    Sipila, Hannu
    Teras, Mika
    Knuuti, Juhani
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [4] Patient motion correction for dynamic cardiac PET: Current status and challenges
    Yihuan Lu
    Chi Liu
    Journal of Nuclear Cardiology, 2020, 27 : 1999 - 2002
  • [5] Patient motion correction for dynamic cardiac PET: Current status and challenges
    Lu, Yihuan
    Liu, Chi
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (06) : 1999 - 2002
  • [6] Cardiac motion and spillover correction for quantitative PET imaging using dynamic MRI
    Marchesseau, Stephanie
    Totman, John J.
    Fadil, Hakim
    Leek, Francesca A. A.
    Chaal, Jasper
    Richards, Mark
    Chan, Mark
    Reilhac, Anthonin
    MEDICAL PHYSICS, 2019, 46 (02) : 726 - 737
  • [7] Motion Correction for Respiratory Gated PET Images
    Detorie, Nicole
    Dahlbom, Magnus
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3273 - 3277
  • [8] Motion Correction and Attenuation Correction for Respiratory Gated PET Images
    Bai, Wenjia
    Brady, Michael
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 351 - 365
  • [9] Patient body motion correction for dynamic cardiac PET-CT by attenuation-emission alignment according to projection consistency conditions
    Hunter, Chad R. R. N.
    Klein, Ran
    Alessio, Adam M.
    deKemp, Robert A.
    MEDICAL PHYSICS, 2019, 46 (04) : 1697 - 1706
  • [10] Evaluation of a respiratory motion correction algorithm for PET images using a customized dynamic phantom
    Cuenca, T.
    Prieto, E.
    Irazola, L.
    Soria, L.
    Moran, V.
    Betech-Antar, V.
    Minguez, F.
    Garcia-Velloso, M. J.
    Marti-Climent, J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S163 - S164