In Vivo Transdermal Multi-Ion Monitoring with a Potentiometric Microneedle-Based Sensor Patch

被引:43
作者
Molinero-Fernandez, Agueda [1 ]
Casanova, Ana [1 ]
Wang, Qianyu [1 ]
Cuartero, Maria [1 ,2 ]
Crespo, Gaston A. [1 ,2 ]
机构
[1] KTH Royal Inst Technol, Sch Engn Sci Chem Biotechnol & Hlth, Dept Chem, SE-10044 Stockholm, Sweden
[2] Univ Catolica San Antonio Murcia, UCAM HiTech, UCAM SENS, Murcia 30107, Spain
基金
瑞典研究理事会;
关键词
multi-ion detection; microneedle sensor; wearable epidermal patch; multiplex intradermal analysis; in vivo measurements; PH; FLUID; TIME;
D O I
10.1021/acssensors.2c01907
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Microneedle sensor technology offers exciting opportunities for decentralized clinical analyses. A novel issue puts forward herein is to demonstrate the uniqueness of membrane-based microneedles to accomplish real-time, on-body monitoring of multiple ions simultaneously. The use of multi-ion detection is clinically relev a n t since it is expected to provide a more complete and reliable assessment of the clinical status of a subject concerning electrolyte disorders and others. We present a microneedle system for transdermal multiplexed tracing of pH, Na+ , K+ , Ca2+ , Li+ , and Cl-. The device consists of an array of seven solid microneedles externally modified to provide six indicator electrodes, each selective for a different ion, and a common reference electrode, all integrated into a wearable patch read in a potentiometric mode. We show in vitro measurements at the expected clinical levels, resulting in a fast response time, excellent reversibility and repeatabi l i t y , and adequate selecti v i t y . Close-to-Nernstian sensitivity, sufficient stabi l i t y and resiliency to skin penetration guarantee the sensor's success in transdermal measurements, which we demonstrate through ex vivo (with pieces of rat skin) and in vivo (on-body measurements in rats) tests. Accuracy is evaluated by comparison with gold standard techniques to characterize collected dermal fluid, blood, and serum. In the past, interstitial fluid (ISF) analysis has been challen g i n g due to difficult sample collection and analysis. For ions, this has resulted in extrapolations from blood concentrations (invasive tests) rather than pure measurements in ISF. The developed microneedle patch is a relevant analytical tool to address this information gap.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 30 条
[1]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[2]   Cytotoxicity Study of Ionophore-Based Membranes: Toward On Body and in Vivo Ion Sensing [J].
Canovas, Rocio ;
Sanchez, Sara Padrell ;
Parrilla, Marc ;
Cuartero, Maria ;
Crespo, Gaston A. .
ACS SENSORS, 2019, 4 (09) :2524-2535
[3]   Wearable Potentiometric Sensors for Medical Applications [J].
Cuartero, Maria ;
Parrilla, Marc ;
Crespo, Gaston A. .
SENSORS, 2019, 19 (02)
[4]   Acid-Base and Electrolyte Disorders in Patients with and without Chronic Kidney Disease: An Update [J].
Dhondup, Tsering ;
Qian, Qi .
KIDNEY DISEASES, 2017, 3 (04) :136-148
[5]   Biochemistry Changes That Occur after Death: Potential Markers for Determining Post-Mortem Interval [J].
Donaldson, Andrea E. ;
Lamont, Iain L. .
PLOS ONE, 2013, 8 (11)
[6]  
Feher J, 2017, QUANTITATIVE HUMAN P, V2nd, P689
[7]   Potassium Level Variation Following Packed Cell Transfusion in Critically Ill Adult Patients-How Alert Should We Be? [J].
Frenkel, Amit ;
Hassan, Lior ;
Glick, Aviad ;
Pikovsky, Oleg ;
Boyko, Matthew ;
Binyamin, Yair ;
Novack, Victor ;
Klein, Moti .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (11)
[8]   Microneedle based electrochemical (Bio)Sensing: Towards decentralized and continuous health status monitoring [J].
Garcia-Guzman, Juan Jose ;
Perez-Rafols, Clara ;
Cuartero, Maria ;
Crespo, Gaston A. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 135
[9]   Effect of microneedle design on pain in human volunteers [J].
Gill, Harvinder S. ;
Denson, Donald D. ;
Burris, Brett A. ;
Prausnitz, Mark R. .
CLINICAL JOURNAL OF PAIN, 2008, 24 (07) :585-594
[10]   Accessing analytes in biofluids for peripheral biochemical monitoring [J].
Heikenfeld, Jason ;
Jajack, Andrew ;
Feldman, Benjamin ;
Granger, Steve W. ;
Gaitonde, Supriya ;
Begtrup, Gavi ;
Katchman, Benjamin A. .
NATURE BIOTECHNOLOGY, 2019, 37 (04) :407-419