Marginal and Internal Adaptation of Different Superstructure and Abutment Materials Using Two Different Implant Systems for Five-Unit Implant-Supported Fixed Partial Dentures: An In Vitro Study

被引:15
|
作者
Kahramanoglu, Erkut [1 ]
Kulak-Ozkan, Yasemin [1 ]
机构
[1] Univ Marmara, Dept Prosthet Dent, Istanbul, Turkey
关键词
dental implants; marginal and internal adaptation; restorative materials; ONE-PIECE CASTINGS; DENTAL PROSTHESES; CERAMIC CROWNS; FIT; FRAMEWORKS; METAL; ACCURACY; ZIRCONIA; TITANIUM; COPINGS;
D O I
10.11607/jomi.2744
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the marginal and internal adaptation of five-unit implant-supported fixed partial dentures with different superstructure and abutment materials with two different implant systems. Materials and Methods: Two mandibular epoxy resin models (one for each implant system) were fabricated, and implants were inserted in the canine, first premolar, and first molar regions. Thirty impressions of each model were then made. The 30 models of each group were divided into three subgroups: group 1, titanium abutment with metal (nickel-chromium) framework; group 2, titanium abutment with zirconium framework; and group 3, zirconium abutment with zirconium framework. The replica technique was used to examine the marginal and internal gap values. For each restoration, 20 measurements were performed, and the data were evaluated statistically using analysis of variance and the least significant difference post hoc test. Results: The highest values for internal adaptation were observed at the occlusal surface in all groups. There were statistically significant differences in marginal measurements between subgroups. The smallest gaps were found in group 1 (79.361 mu m), and the largest gaps were found in group 3 (131.242 mu m). Conclusions: In this study, marginal and internal gap measurements were 79 to 131 mu m. The marginal discrepancy of the tested materials could be considered clinically acceptable.
引用
收藏
页码:1207 / 1216
页数:10
相关论文
共 33 条
  • [31] Influence of Connector Design on Displacement and Micromotion in Tooth-Implant Fixed Partial Dentures Using Different Lengths and Diameters: A Three-Dimensional Finite Element Study
    Mously, Hisham A.
    Naguib, Ghada H.
    Hashem, Abou Bakr Hossam
    Abougazia, Ahmed O.
    Binmahfooz, Abdulelah M.
    Hamed, Mohamed T.
    MATERIALS, 2024, 17 (17)
  • [32] Comparison of plaque accumulation and soft-tissue blood flow with the use of full-arch implant-supported fixed prostheses with mucosal surfaces of different materials: a randomized clinical study
    Kanao, Masato
    Nakamoto, Tetsuji
    Kajiwara, Norihiro
    Kondo, Yusuke
    Masaki, Chihiro
    Hosokawa, Ryuji
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (10) : 1137 - 1143
  • [33] Early loading of splinted implants supporting a two-unit fixed partial denture in the posterior maxilla: 13-month results from a randomized controlled clinical trial of two different implant systems
    Ryu, Hyo-Sook
    Namgung, Cheol
    Heo, Young-Ku
    Lee, Jong-Ho
    Lim, Young-Jun
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (08) : 1017 - 1025