Non-enzymatic Amperometric Sensor for H2O2 Based on MnCO3 Thin Film Electrodes

被引:0
|
作者
Stojkovikj, Sasho [1 ]
Najdoski, Metodija [1 ]
Sefer, Birhan [1 ,2 ]
Mirceski, Valentin [1 ]
机构
[1] Ss Cyril & Methodius Univ, Fac Nat Sci & Math, Inst Chem, Arhimedova 3,POB 162, Skopje 1000, Macedonia
[2] Friedrich Alexander Univ Erlangen Nuremberg, Dept Mat Sci & Engn, Inst Surface Sci & Corros, D-91058 Erlangen, Germany
关键词
amperometric sensors; hydrogen peroxide; manganese(II) carbonate thin films; electrocatalysis; HYDROGEN-PEROXIDE; SPECTROPHOTOMETRIC DETERMINATION; OXIDE; GRAPHENE; NANOCOMPOSITE; REDUCTION; TRACKING; HYBRID; ACID;
D O I
10.5562/cca3424
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The present study describes development of a non-enzymatic amperometric sensor for detection of H2O2 based on MnCO3 thin film electrodes. The film was deposited on electroconductive FTO coated glass substrates using simple chemical bath deposition method. The phase composition of the thin film was confirmed by X-ray diffraction analysis. The electrochemical properties and the sensor sensitivity towards H2O2 were examined using cyclic voltammetry and chronoamperometry in 0.1 M phosphate buffer solution with pH = 7.5. It was revealed that the sensing mechanism is based on electrocatalytic oxidation of H2O2, involving Mn species as redox mediators. According to the results, the best sensor response towards H2O2 was found at E = +0.25 V, with detection limit and sensor sensitivity of 10.0 mu M and 2.64 mu A cm(-2) mM(-1) (for the range of 0.09-1.8 mM), respectively, associated with R-2 = 0.999.
引用
收藏
页码:567 / 575
页数:9
相关论文
共 50 条
  • [1] A disposable non-enzymatic dual sensor for simultaneous amperometric determination of NADH and H2O2
    Eda Kıymaz Onat
    Melike Bilgi Kamaç
    Merve Yılmaz
    Journal of Applied Electrochemistry, 2023, 53 : 2213 - 2227
  • [2] A disposable non-enzymatic dual sensor for simultaneous amperometric determination of NADH and H2O2
    Onat, Eda Kiymaz
    Kamac, Melike Bilgi
    Yilmaz, Merve
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2023, 53 (11) : 2213 - 2227
  • [3] Non-enzymatic SnO2-nanowire/GCE amperometric sensor for H2O2 sensing
    Zou, Guihua
    Sun, Liping
    Huo, Lihua
    Zhao, Hui
    MICROCHEMICAL JOURNAL, 2024, 203
  • [4] Translating potentiometric detection into non-enzymatic amperometric measurement of H2O2
    Yin, Tanji
    Wang, Hemin
    Li, Jinghui
    Yuan, Baiqing
    Qin, Wei
    TALANTA, 2021, 232
  • [5] Study of the application of a Cu2O thin film as non-enzymatic amperometric glucose sensor
    Figueredo, Francisco
    Henriquez, Rodrigo
    Munoz, Eduardo
    Heyser, Cristopher
    Schrebler, Ricardo
    Grez, Paula
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 971
  • [6] MWCNT Based Non-Enzymatic H2O2 Sensor: Influence of Amine Functionalization on the Electrochemical H2O2 Sensing
    Revathi, C.
    Rajavel, K.
    Saranya, M.
    Kumar, R. T. Rajendra
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (13) : B627 - B632
  • [7] NON-ENZYMATIC OXIDATION OF IAA BY H2O2
    BRENNAN, T
    JACOBS, WP
    FRENKEL, C
    PLANT PHYSIOLOGY, 1978, 61 (04) : 64 - 64
  • [8] Non-Enzymatic CO3O4 Nanostructure-Based Electrochemical Sensor for H2O2 Detection
    Mizers, V.
    Gerbreders, V.
    Krasovska, M.
    Sledevskis, E.
    Mihailova, I.
    Ogurcovs, A.
    Bulanovs, A.
    Gerbreders, A.
    LATVIAN JOURNAL OF PHYSICS AND TECHNICAL SCIENCES, 2023, 60 (06) : 63 - 84
  • [9] A non-enzymatic sensor for sensitive determination of H2O2 using biomimetic nanocomposite
    Mukherjee, Atripan
    Ashrafi, Amir
    Richtera, Lukas
    Adam, Vojtech
    MENDELNET 2019: PROCEEDINGS OF 26TH INTERNATIONAL PHD STUDENTS CONFERENCE, 2019, : 585 - 590
  • [10] Non-enzymatic CuCr2O4/GCE amperometric sensor for high sensing and rapid detection of nM level H2O2
    Kong, De-Rui
    Xin, Yu-Ying
    Li, Bo
    Zhang, Xian-Fa
    Deng, Zhao-Peng
    Gao, Shan
    MICROCHEMICAL JOURNAL, 2023, 194