The DIAMANT electronics and data acquisition system

被引:3
作者
Aiche, M
Aleonard, MM
Balauge, B
Barreau, MM
Bourgine, B
Cabaussel, D
Chemin, JF
Diarra, C
Goudour, JP
Harston, M
Rasolofo, H
Scheurer, JN
Brondi, A
LaRana, G
Moro, R
Vardaci, E
Curien, D
机构
[1] UNIV BORDEAUX 1,CEN BORDEAUX GRADIGNAN,CNRS,IN2P3,F-33175 GRADIGNAN,FRANCE
[2] IST NAZL FIS NUCL,I-80125 NAPLES,ITALY
[3] UNIV NAPLES,DIPARTIMENTO SCI FIS,I-80125 NAPLES,ITALY
[4] CTR RECH NUCL,IN2P3,F-67037 STRASBOURG,FRANCE
关键词
data acquisition; light charged particle; multidetector; DIAMANT;
D O I
10.1016/S0168-9002(97)00470-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the electronics and data acquisition system of the 4 pi light particle multidetector array DIAMANT. This system has been conceived to be very modular with regard to both the kind and number of detectors. The whole system is designed to run either with a few additional ancillary detectors (Ge) or linked to 4 pi gamma arrays such as EUROGAM. Part of the electronics has been designed using SMD devices; the acquisition is based on CAMAC ADCs and VME units for data acquisition, data transfer is handled via a 32bit ECL bus (DT32) used for EUROGAM. The data acquisition, distributed on a network, is based on the VxWorks Real Time kernel and the UNIX Operating System.
引用
收藏
页码:329 / 337
页数:9
相关论文
共 19 条
[1]   A VXI BASED READOUT SYSTEM FOR EUROGAM [J].
ALEONARD, MM ;
ALEXANDER, J ;
CRESSWELL, J ;
GOUILLAUD, JC ;
KARKOUR, N ;
LAZARUS, I ;
MCPHERSON, G ;
PEDROZA, JL ;
PUCKNELL, V ;
REBII, A ;
RICHARD, A ;
RING, C ;
THORNHILL, J ;
WILKINSON, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :892-896
[2]  
Alexander Jacqui, COMMUNICATION
[3]   EUROBALL - LARGE GAMMA-RAY SPECTROMETERS THROUGH EUROPEAN COLLABORATIONS [J].
BECK, FA .
PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 1992, 28 :443-461
[4]   A SCINTILLATION COUNTER WITH NEUTRON AND GAMMA-RAY DISCRIMINATORS [J].
BROOKS, FD .
NUCLEAR INSTRUMENTS & METHODS, 1959, 4 (03) :151-163
[5]  
CONDAT I, 1994, ETUDE REPONSE CELLUL
[6]  
DIARRA C, 1994, THESIS U BORDEAUX 1
[7]   A METHOD FOR PULSE SHAPE DISCRIMINATION [J].
FULLE, R ;
MATHE, G ;
NETZBAND, D .
NUCLEAR INSTRUMENTS & METHODS, 1965, 35 (02) :250-+
[8]  
HATLEY DJ, 1991, STRUCTURE ANAL REAL
[9]  
KOCH L, NUCL ELECT, V1, P5
[10]   THE SILICON BALL - A 4-PI SI DETECTOR ARRAY FOR REACTION CHANNEL SELECTION [J].
KUROYANAGI, T ;
MITARAI, S ;
SUEMATSU, S ;
MIN, BJ ;
TOMURA, H ;
MUKAI, J ;
MAEDA, T ;
NAKATANI, R ;
SLETTEN, G ;
NYBERG, J ;
JERRESTAM, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 316 (2-3) :289-296