Kalman Filtering with Optimized Parameters for Gas Measurement Using Laser Absorption Spectroscopy

被引:6
作者
Li Jinyi [1 ]
Yang Xue [1 ]
Zhang Chenge [1 ]
Xue Fuzhen [2 ]
Yang Xiaotao [3 ]
机构
[1] Tiangong Univ, Sch Control Sci & Engn, Tianjin Key Lab Intelligent Control Elect Equipme, Tianjin 300387, Peoples R China
[2] PipeChina Eastern Crude Oil Storage & Transportat, Xuzhou 221008, Jiangsu, Peoples R China
[3] Harbin Engn Univ, Coll Power & Energy Engn, Harbin 150001, Heilongjiang, Peoples R China
关键词
spectroscopy; tunable diode laser absorption spectroscopy; Kalman filtering; measurement precision; parameter optimization; SENSOR;
D O I
10.3788/AOS202242.1830001
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Tunable diode laser absorption spectroscopy (TDLAS) technology is inevitably interfered by optical fringes, detector noise, and circuit noise during measurement, which results in large output fluctuations. The use of the Kalman filter to post-process the measurement results can effectively improve the measurement precision and anti- interference ability of the TDLAS system. This study focuses on the ratio g of the measured noise covariance sigma(2)(V) to the process excitation noise covariance s2W in the Kalman filtering algorithm. Starting with the fluctuation and the response time of the Kalman filter output, the comprehensive effect evaluation index R of the filter is obtained by assigning them different weights, and the comprehensive research on the relationship between R and g shows that the optimal g is 27. Moreover, the advantages of Kalman filtering in anti-interference and stability over smooth filtering and extended state filtering are verified by simulations. The Kalman filter with optimized parameters is applied in the TDLAS ammonia escape detection, and the measurement precision of concentration of NH3 with a volume fraction of 4. 7x10(-6), concentration of NH3 with a volume fraction of 108x10(-6), H2O concentration, and temperature is increased by 3. 54, 3. 48, 3. 00, and 2. 80 times, respectively.
引用
收藏
页数:8
相关论文
共 21 条
[1]  
Bai WY, 2014, CHIN CONTR CONF, P2608, DOI 10.1109/ChiCC.2014.6897047
[2]  
Bai WY, 2015, 2015 54TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), P712, DOI 10.1109/SICE.2015.7285553
[3]  
Chen J J, 2018, TRACE GASES ISOTOPES
[4]   Mid-Infrared Tunable Laser-Based Broadband Fingerprint Absorption Spectroscopy for Trace Gas Sensing: A Review [J].
Du, Zhenhui ;
Zhang, Shuai ;
Li, Jinyi ;
Gao, Nan ;
Tong, Kebin .
APPLIED SCIENCES-BASEL, 2019, 9 (02)
[5]   Applications of Kalman filtering to real-time trace gas concentration measurements [J].
Leleux, DP ;
Claps, R ;
Chen, W ;
Tittel, FK ;
Harman, TL .
APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 74 (01) :85-93
[6]   A Review of Signal Enhancement and Noise Reduction Techniques for Tunable Diode Laser Absorption Spectroscopy [J].
Li, Jingsong ;
Yu, Benli ;
Zhao, Weixiong ;
Chen, Weidong .
APPLIED SPECTROSCOPY REVIEWS, 2014, 49 (08) :666-691
[7]   Standoff Chemical Detection Using Laser Absorption Spectroscopy: A Review [J].
Li, Jinyi ;
Yu, Ziwei ;
Du, Zhenhui ;
Ji, Yue ;
Liu, Chang .
REMOTE SENSING, 2020, 12 (17) :1-44
[8]   In situ, portable and robust laser sensor for simultaneous measurement of ammonia, water vapor and temperature in denitrification processes of coal fired power plants [J].
Li, Jinyi ;
Zhang, Chenge ;
Wei, Yingying ;
Du, Zhenhui ;
Sun, Fushuang ;
Ji, Yue ;
Yang, Xiaotao ;
Liu, Chang .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 305
[9]   Hollow waveguide enhanced dimethyl sulfide sensor based on a 3.3 μm interband cascade laser [J].
Li, Jinyi ;
Luo, Gang ;
Du, Zhenhui ;
Ma, Yiwen .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 :3550-3557
[10]   Optimized Gas Detection Method Based on Variational Mode -Decomposition Algorithm [J].
Liang Yu ;
Liu Tiegen ;
Liu Kun ;
Jiang Junfeng ;
Li Yafan .
CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2021, 48 (07)