Robust Estimation of Kinetic Parameters in Dynamic PET Imaging

被引:0
|
作者
Gao, Fei [1 ]
Liu, Huafeng [1 ]
Shi, Pengcheng [1 ]
机构
[1] Rochester Inst Technol, Golisano Coll Comp & Informat Sci, Rochester, NY 14623 USA
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I | 2011年 / 6891卷
关键词
DIRECT RECONSTRUCTION; IMAGES; MAPS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Dynamic PET imaging provides important information for biological research, clinical diagnosis and pharmacokinetic analysis through kinetic modeling and data-driven parameter estimation. Kinetic parameters quantitatively describe dynamic material exchange and metabolism of radiotracers in plasma and tissues. While many efforts have been devoted to estimate kinetic parameters from dynamic PET, the poor statistical properties of the measurement data in low count dynamic acquisition and the uncertainties in estimating the arterial input function have limited the accuracy and reliability of the kinetic parameter estimation. Additionally, the quantitative analysis of individual kinetic parameters is not yet implemented. In this paper, we present a robust kinetic parameter estimation framework which is robust to both the poor statistical properties of measurement data in dynamic PET and the uncertainties in estimated arterial input function, and is able to analyze every single kinetic parameter quantitatively. The strategy is optimized with robust H-infinity estimation under minimax criterion. Experiments are conducted on Monte Carlo sirnulated data set for quantitative analysis and validation, and on real patient scans for assessment of clinical potential.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 50 条
  • [31] Bidirectional Motion Estimation with Cyclic Cost Volume for High Dynamic Range Imaging
    Vien, An Gia
    Park, Seonghyun
    Mai, Truong Thanh Nhat
    Kim, Gahyeon
    Lee, Chul
    2022 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, CVPRW 2022, 2022, : 1182 - 1189
  • [32] Kinetic parameter estimation of hepatocellular carcinoma on 18F-FDG PET/CT based on Bayesian method
    He, Jianfeng
    Li, Yongjin
    Wang, Tao
    Deng, Yinglei
    Wang, Shaobo
    MEDICAL PHYSICS, 2023, 50 (05) : 2860 - 2871
  • [33] Robust nonlinear parameter estimation in tracer kinetic analysis using infinity norm regularization and particle swarm optimization
    Kang, Seung Kwan
    Seo, Seongho
    Lee, Chul-Hee
    Kim, Mi Jeong
    Kim, Su Jin
    Lee, Jae Sung
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 72 : 60 - 72
  • [34] Inter-Pass Motion Correction for Whole-Body Dynamic PET and Parametric Imaging
    Guo, Xueqi
    Wu, Jing
    Chen, Ming-Kai
    Liu, Qiong
    Onofrey, John A.
    Pucar, Darko
    Pang, Yulei
    Pigg, David
    Casey, Michael E.
    Dvornek, Nicha C.
    Liu, Chi
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (04) : 344 - 353
  • [35] Fourier Domain Closed-Form Formulas for Estimation of Kinetic Parameters in Multi-Compartment Models
    Zeng, Gengsheng L.
    Kadrmas, Dan J.
    Gullberg, Grant T.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3209 - 3216
  • [36] Iterative reweighted linear least squares for accurate, fast, and robust estimation of diffusion magnetic resonance parameters
    Collier, Quinten
    Veraart, Jelle
    Jeurissen, Ben
    den Dekker, Arnold J.
    Sijbers, Jan
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) : 2174 - 2184
  • [37] Zero-Extra-Dose PET Delayed Imaging with Data-Driven Attenuation Correction Estimation
    Pang, Lifang
    Zhu, Wentao
    Dong, Yun
    Lv, Yang
    Shi, Hongcheng
    MOLECULAR IMAGING AND BIOLOGY, 2019, 21 (01) : 149 - 158
  • [38] Analysis of Morphometric Parameters in Cervical Canal Stenosis on Neutral and Dynamic Magnetic Resonance Imaging
    Tykocki, Tomasz
    du Plessis, Johannes
    Wynne-Jones, Guy
    WORLD NEUROSURGERY, 2018, 114 : E317 - E322
  • [39] Fourier domain closed-form formulas for estimation of kinetic parameters in reversible multi-compartment models
    Zeng, Gengsheng L.
    Kadrmas, Dan J.
    Gullberg, Grant T.
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [40] Dynamic lung compliance imaging from 4DCT-derived volume change estimation
    Nair, Girish B.
    Al-Katib, Sayf
    Podolsky, Robert
    Quinn, Thomas
    Stevens, Craig
    Castillo, Edward
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (21)