Robust Estimation of Kinetic Parameters in Dynamic PET Imaging

被引:0
|
作者
Gao, Fei [1 ]
Liu, Huafeng [1 ]
Shi, Pengcheng [1 ]
机构
[1] Rochester Inst Technol, Golisano Coll Comp & Informat Sci, Rochester, NY 14623 USA
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I | 2011年 / 6891卷
关键词
DIRECT RECONSTRUCTION; IMAGES; MAPS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Dynamic PET imaging provides important information for biological research, clinical diagnosis and pharmacokinetic analysis through kinetic modeling and data-driven parameter estimation. Kinetic parameters quantitatively describe dynamic material exchange and metabolism of radiotracers in plasma and tissues. While many efforts have been devoted to estimate kinetic parameters from dynamic PET, the poor statistical properties of the measurement data in low count dynamic acquisition and the uncertainties in estimating the arterial input function have limited the accuracy and reliability of the kinetic parameter estimation. Additionally, the quantitative analysis of individual kinetic parameters is not yet implemented. In this paper, we present a robust kinetic parameter estimation framework which is robust to both the poor statistical properties of measurement data in dynamic PET and the uncertainties in estimated arterial input function, and is able to analyze every single kinetic parameter quantitatively. The strategy is optimized with robust H-infinity estimation under minimax criterion. Experiments are conducted on Monte Carlo sirnulated data set for quantitative analysis and validation, and on real patient scans for assessment of clinical potential.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 50 条
  • [1] Sparsity Constrained Mixture Modeling for the Estimation of Kinetic Parameters in Dynamic PET
    Lin, Yanguang
    Haldar, Justin P.
    Li, Quanzheng
    Conti, Peter S.
    Leahy, Richard M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) : 173 - 185
  • [2] Performance evaluation of kinetic parameter estimation methods in dynamic FDG-PET studies
    Dai, Xiaoqian
    Chen, Zhe
    Tian, Jie
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (01) : 4 - 16
  • [3] Direct and indirect parameter imaging methods for dynamic PET
    Mao, Xin
    Zhao, Shujun
    Gao, Dongfang
    Hu, Zhanli
    Zhang, Na
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04):
  • [4] High-temporal-resolution dynamic PET imaging based on a kinetic-induced voxel filter
    Fu, Liwen
    Chen, Zixiang
    Duan, Yanhua
    Cheng, Zhaoping
    Chen, Lingxin
    Yang, Yongfeng
    Zheng, Hairong
    Liang, Dong
    Pang, Zhi-feng
    Hu, Zhanli
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (04):
  • [5] Estimation of Dynamic Parameters of Cardiac Ventricles
    Xu, YiQiang
    Guan, Qiu
    Chen, S. Y.
    MCBC'09: PROCEEDINGS OF THE 10TH WSEAS INTERNATIONAL CONFERENCE ON MATHEMATICS AND COMPUTERS IN BIOLOGY AND CHEMISTRY, 2009, : 25 - +
  • [6] Indirect methods for improving parameter estimation of PET kinetic models
    Huang, Hsuan-Ming
    Liu, Chih-Chieh
    Lin, Chieh
    MEDICAL PHYSICS, 2019, 46 (04) : 1777 - 1784
  • [7] Accelerated PET kinetic maps estimation by analytic fitting method
    Scipioni, Michele
    Giorgetti, Assuero
    Della Latta, Daniele
    Fucci, Sabrina
    Positano, Vincenzo
    Landini, Luigi
    Santarelli, Maria Filomena
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 99 : 221 - 235
  • [8] Magia: Robust Automated Image Processing and Kinetic Modeling Toolbox for PET Neuroinformatics
    Karjalainen, Tomi
    Tuisku, Jouni
    Santavirta, Severi
    Kantonen, Tatu
    Bucci, Marco
    Tuominen, Lauri
    Hirvonen, Jussi
    Hietala, Jarmo
    Rinne, Juha O.
    Nummenmaa, Lauri
    FRONTIERS IN NEUROINFORMATICS, 2020, 14
  • [9] Robustness of post-reconstruction and direct kinetic parameter estimates under rigid head motion in dynamic brain PET imaging
    Kotasidis, F. A.
    Angelis, G. I.
    Anton-Rodriguez, J. M.
    Zaidi, H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 53 : 40 - 55
  • [10] Robust High Dynamic Range Imaging by Rank Minimization
    Oh, Tae-Hyun
    Lee, Joon-Young
    Tai, Yu-Wing
    Kweon, In So
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2015, 37 (06) : 1219 - 1232