Internal winding faults in three-phase five-limb transformer

被引:4
作者
Pérez-Rojas, C
García-Martínez, S
机构
来源
2005 2nd International Conference on Electrical & Electronics Engineering (ICEEE) | 2005年
关键词
transformer; saturation; internal winding faults;
D O I
10.1109/ICEEE.2005.1529633
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a three-phase five-limb transformer is used to include some changes to modelling internal winding faults. The developed model is based on primitive parameters and it takes into account the physical dimensions at different regions of the iron core, the nonlinear effects of magnetic saturation and the effect of internal windings faults on the three-phase transformer.
引用
收藏
页码:314 / 317
页数:4
相关论文
共 50 条
  • [1] Modelling and Analysis of a Three-Phase to Five-Phase Transformer
    Khan, M. Rizwan
    Alammari, Rashid
    Moinoddin, Shaikh
    Iqbal, Atif
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2014, 15 (04) : 401 - 410
  • [2] Modelling of three-limb wound magnetic core of three-phase transformer with disconnected neutral wire of primary winding
    Sosinski, Rafal
    PRZEGLAD ELEKTROTECHNICZNY, 2007, 83 (04): : 109 - 111
  • [3] A static three-phase to five-phase transformer based on Scott connection
    Abdel-Khalik, A. S.
    Shafik, Z.
    Elserougi, A.
    Ahmed, S.
    Massoud, A.
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 110 : 84 - 93
  • [4] Extended Wing Technique Approach for the Detection of Winding Intertum Faults in Three-phase Transformers
    Ballal, Makarand Sudhakar
    Suryawanshi, Hiralal Murlidhar
    Choudhari, Bhupesh Nemiehand
    JOURNAL OF POWER ELECTRONICS, 2015, 15 (01) : 288 - 297
  • [5] Research on winding vibration of a three-phase transformer under an AC/DC hybrid environment
    Liu T.
    Su H.
    Pan C.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (08): : 61 - 68
  • [6] A Novel Three-Phase to Five-Phase Transformation Using a Special Transformer Connection
    Iqbal, Atif
    Moinuddin, Shaikh
    Khan, M. Rizwan
    Ahmed, Sk. Moin
    Abu-Rub, Haithem
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1637 - 1644
  • [7] A Scott Connection-Based Three-Phase to Five-Phase Power Transformer
    Abdel-Khalik, A. S.
    Elserougi, A.
    Shafik, Z.
    Ahmed, S.
    Massoud, A.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 2559 - 2564
  • [8] Characteristics of transformer parameters during internal winding faults based on experimental measurements
    Palmer-Buckle, P
    Butler, KL
    Sarma, NDR
    1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 882 - 887
  • [9] Simulation Study on the Unbalanced Operation Characteristics of a Three-Phase Auto-Transformer with Asymmetrical Winding Parameters
    Chen, Liangyuan
    2017 INTERNATIONAL CONFERENCE ON COMPUTER SYSTEMS, ELECTRONICS AND CONTROL (ICCSEC), 2017, : 193 - 195
  • [10] Anisotropy in three-phase transformer circuit model
    Elleuch, M
    Poloujadoff, M
    IEEE TRANSACTIONS ON MAGNETICS, 1997, 33 (05) : 4319 - 4326