Electrochemiluminescence biosensor for ultrasensitive determination of ochratoxin A in corn samples based on aptamer and hyperbranched rolling circle amplification

被引:97
作者
Yang, Linlin [1 ]
Zhang, Ying [1 ]
Li, Ruibao [1 ]
Lin, Cuiying [1 ]
Guo, Longhua [1 ]
Qiu, Bin [1 ]
Lin, Zhenyu [1 ]
Chen, Guonan [1 ]
机构
[1] Fuzhou Univ, Inst Nanomed & Nanobiosensing, Coll Chem, MOE Key Lab Anal & Detect Food Safety,Fujian Prov, Fuzhou 350116, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Ochratoxin A; Aptamer; Electrochemiluminescence; Hyperbranched rolling circle amplification; Corn; SENSITIVE DETECTION; ELECTROCHEMICAL APTASENSOR; HPLC DETERMINATION; CHAIN-REACTION; DNA; ASSAY; CHEMILUMINESCENCE; MYCOTOXINS; STRATEGY; SYSTEM;
D O I
10.1016/j.bios.2015.03.067
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Determination of ochratoxin A (OTA) is highly important for food safety control. In this study, a signal-on electrochemiluminescence (ECL) biosensor which combined the characteristics of high efficiency of hyperbranched rolling circle amplification (HRCA) and high selectivity of aptamer was developed for OTA determination. The capture probe DNA (CDNA) was firstly immobilized on the gold electrode surface through Au-S interaction, then the OTA aptamer was modified on the electrode surface through hybridization with CDNA. Since OTA can competitively bind with the aptamer due to their high affinity, which would induce the releasing of aptamer from the electrode surface. Subsequently, the free CDNA on the electrode surface can hybridize with the padlock probe and induce HRCA reaction subsequently. Thus, the HRCA products which contained large amount of double-stranded DNA (dsDNA) fragments can be accumulated on the electrode surface, Since Ru(phen)(3)(2+) can intercalate into the groove of dsDNA and acts as ECL indicator, high ECL intensity can be detected from the electrode surface. The enhanced ECL intensity has a linear relationship with OTA in the range of 0.05-500 pg/mL with a correlation coefficient of 0.9957, and the limit of detection (LOD) was 0.02 pg/mL. The developed biosensor has been applied to determine OTA concentration in the corn samples with satisfied results. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:268 / 274
页数:7
相关论文
共 44 条
[11]   HPLC determination of ochratoxin a in a low volume of human blood serum [J].
Ghali, R. ;
Hmaissia-Khlifa, K. ;
Mezigh, Ch. ;
Ghorbel, H. ;
Maaroufi, K. ;
Maschgoul, S. ;
Hedilli, A. .
ANALYTICAL LETTERS, 2008, 41 (05) :757-766
[12]   Polymerase chain reaction in polymeric microchips:: DNA amplification in less than 240 seconds [J].
Giordano, BC ;
Ferrance, J ;
Swedberg, S ;
Hühmer, AFR ;
Landers, JP .
ANALYTICAL BIOCHEMISTRY, 2001, 291 (01) :124-132
[13]   CHEMILUMINESCENCE RESULTING FROM ELECTROCHEMICALLY GENERATED SPECIES [J].
HERCULES, DM .
SCIENCE, 1964, 145 (363) :808-&
[14]   Rolling Chain Amplification Based Signal-Enhanced Electrochemical Aptasensor for Ultrasensitive Detection of Ochratoxin A [J].
Huang, Lin ;
Wu, Jingjing ;
Zheng, Lei ;
Qian, Haisheng ;
Xue, Feng ;
Wu, Yucheng ;
Pan, Daodong ;
Adeloju, Samuel B. ;
Chen, Wei .
ANALYTICAL CHEMISTRY, 2013, 85 (22) :10842-10849
[15]   Signal amplified strategy based on target-induced strand release coupling cleavage of nicking endonuclease for the ultrasensitive detection of ochratoxin A [J].
Hun, Xu ;
Liu, Fang ;
Mei, Zhenhua ;
Ma, Lifeng ;
Wang, Zhouping ;
Luo, Xiliang .
BIOSENSORS & BIOELECTRONICS, 2013, 39 (01) :145-151
[16]   Amplified impedimetric aptasensor based on gold nanoparticles covalently bound graphene sheet for the picomolar detection of ochratoxin A [J].
Jiang, Ling ;
Qian, Jing ;
Yang, Xingwang ;
Yan, Yuting ;
Liu, Qian ;
Wang, Kan ;
Wang, Kun .
ANALYTICA CHIMICA ACTA, 2014, 806 :128-135
[17]   An aptasensing platform for simultaneous detection of multiple analytes based on the amplification of exonuclease-catalyzed target recycling and DNA concatemers [J].
Jiang, Liping ;
Peng, Jingdong ;
Yuan, Ruo ;
Chai, Yaqin ;
Yuan, Yali ;
Bai, Lijuan ;
Wang, Yan .
ANALYST, 2013, 138 (17) :4818-4822
[18]   Fabricated aptamer-based electrochemical "signal-off" sensor of ochratoxin A [J].
Kuang, Hua ;
Chen, Wei ;
Xu, Dinghua ;
Xu, Liguang ;
Zhu, Yingyue ;
Liu, Liqiang ;
Chu, Huaqin ;
Peng, Chifang ;
Xu, Chuanlai ;
Zhu, Shuifang .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :710-716
[19]   Use of ramification amplification assay for detection of Escherichia coli O157:H7 and other E-coli Shiga toxin-producing strains [J].
Li, F ;
Zhao, CY ;
Zhang, WD ;
Cui, SH ;
Meng, JH ;
Wu, J ;
Zhang, DY .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (12) :6086-6090
[20]   Development of a monoclonal antibody against ochratoxin A and its application in enzyme-linked immunosorbent assay and gold nanoparticle immunochromatographic strip [J].
Liu, Biing-Hui ;
Tsao, Zih-Jay ;
Wang, Jing-Jhih ;
Yu, Feng-Yih .
ANALYTICAL CHEMISTRY, 2008, 80 (18) :7029-7035