Esophageal Doppler Can Predict Fluid Responsiveness Through End-Expiratory and End-Inspiratory Occlusion Tests

被引:33
作者
Depret, Francois [1 ,2 ]
Jozwiak, Mathieu [1 ,2 ]
Teboul, Jean-Louis [1 ,2 ]
Alphonsine, Jean-Emmanuel [1 ,2 ]
Richard, Christian [1 ,2 ]
Monnet, Xavier [1 ,2 ]
机构
[1] Hop Univ Paris Sud, Hop Bicetre, Serv Reanimat Med, 78 Rue Gen Leclerc, F-94270 Le Kremlin Bicetre, France
[2] Univ Paris Sud, INSERM, UMR S 999, 78 Rue Gen Leclerc, F-94270 Le Kremlin Bicetre, France
关键词
esophageal Doppler; fluid responsiveness; heart-lung interactions; mechanical ventilation; volume expansion; CRITICALLY-ILL PATIENTS; INTENSIVE-CARE-UNIT; PRESSURE; MANEUVER; PATIENT; VOLUME;
D O I
10.1097/CCM.0000000000003522
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To assess whether, in patients under mechanical ventilation, fluid responsiveness is predicted by the effects of short respiratory holds on cardiac index estimated by esophageal Doppler. Design: Prospective, monocentric study. Setting: Medical ICU. Patients: Twenty-eight adult patients with acute circulatory failure and a decision of the clinicians in charge to administer fluids. Interventions: Before and after infusing 500 mL of saline, we measured cardiac index estimated by esophageal Doppler before and during the last 5 seconds of successive 15-second end-inspiratory occlusion and end-expiratory occlusion, separated by 1 minute. Patients in whom volume expansion increased cardiac index measured by transpulmonary thermodilution greater than or equal to 15% were defined as "fluid responders." Cardiac index measured by the Pulse Contour Cardiac Output device (from pulse contour analysis or transpulmonary thermodilution) was used as the reference. Measurements and Main Results: End-expiratory occlusion increased cardiac index estimated by esophageal Doppler more in responders than in nonresponders (8% +/- 2% vs 3% +/- 1%, respectively; p < 0.0001) and end-inspiratory occlusion decreased cardiac index estimated by esophageal Doppler more in responders than in nonresponders (-8% +/- 5% vs -4% +/- 2%, respectively; p = 0.0002). Fluid responsiveness was predicted by the end-expiratory occlusion induced percent change in cardiac index estimated by esophageal Doppler with an area under the receiver operating characteristic curve of 1.00 (95% CI, 0.88-1.00) and a threshold value of 4% increase in cardiac index estimated by esophageal Doppler. It was predicted by the sum of absolute values of percent changes in cardiac index estimated by esophageal Doppler during both occlusions with a similar area under the receiver operating characteristic curve (0.99 [0.86-1.00]) and with a threshold of 9% change in cardiac index estimated by esophageal Doppler, which is compatible with the esophageal Doppler precision. Conclusions: If the absolute sum of the percent change in cardiac index estimated by esophageal Doppler induced by two successive end-inspiratory occlusion and end-expiratory occlusion maneuvers is greater than 9%, it is likely that a 500 mL fluid infusion will increase cardiac output. This diagnostic threshold is higher than if only end-expiratory occlusion induced percent changes in cardiac index estimated by esophageal Doppler are taken into account.
引用
收藏
页码:E96 / E102
页数:7
相关论文
共 20 条
[1]   End-Expiratory Occlusion Test Predicts Fluid Responsiveness in Patients With Protective Ventilation in the Operating Room [J].
Biais, Matthieu ;
larghi, MathilDe ;
Henriot, Jeremy ;
de Courson, Hugues ;
Sesay, Musa ;
Nouette-Gaulain, Karine .
ANESTHESIA AND ANALGESIA, 2017, 125 (06) :1889-1895
[2]   Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique [J].
Cecconi, M. ;
Dawson, D. ;
Grounds, R. M. ;
Rhodes, A. .
INTENSIVE CARE MEDICINE, 2009, 35 (03) :498-504
[3]   End-expiratory occlusion maneuver to predict fluid responsiveness in the intensive care unit: an echocardiographic study [J].
Georges, Delphine ;
de Courson, Hugues ;
Lanchon, Romain ;
Sesay, Musa ;
Nouette-Gaulain, Karine ;
Biais, Matthieu .
CRITICAL CARE, 2018, 22
[4]   End-expiratory occlusion manoeuvre does not accurately predict fluid responsiveness in the operating theatre [J].
Guinot, P. -G. ;
Godart, J. ;
de Broca, B. ;
Bernard, E. ;
Lorne, E. ;
Dupont, H. .
BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (06) :1050-1054
[5]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[6]   Pressure Waveform Analysis [J].
Jozwiak, Mathieu ;
Monnet, Xavier ;
Teboul, Jean-Louis .
ANESTHESIA AND ANALGESIA, 2018, 126 (06) :1930-1933
[7]   Predicting Fluid Responsiveness in Critically Ill Patients by Using Combined End-Expiratory and End-Inspiratory Occlusions With Echocardiography [J].
Jozwiak, Mathieu ;
Depret, Francois ;
Teboul, Jean-Louis ;
Alphonsine, Jean-Emmanuel ;
Lai, Christopher ;
Richard, Christian ;
Monnet, Xavier .
CRITICAL CARE MEDICINE, 2017, 45 (11) :E1131-E1138
[8]   Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients [J].
Monnet, X ;
Rienzo, M ;
Osman, D ;
Anguel, N ;
Richard, C ;
Pinsky, MR ;
Teboul, JL .
INTENSIVE CARE MEDICINE, 2005, 31 (09) :1195-1201
[9]   Assessment of changes in left ventricular systolic function with oesophageal Doppler [J].
Monnet, X. ;
Robert, J. -M. ;
Jozwiak, M. ;
Richard, C. ;
Teboul, J. -L. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (05) :743-749
[10]   Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices [J].
Monnet, X. ;
Dres, M. ;
Ferre, A. ;
Le Teuff, G. ;
Jozwiak, M. ;
Bleibtreu, A. ;
Le Deley, M-C ;
Chemla, D. ;
Richard, C. ;
Teboul, J-L .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (03) :330-338